VDO Dayton 4W315C Dayton Diesel Electric Generator, Electrical Specifications, 5000, 6500

Page 2
4W315C

Dayton Operating Instructions and Parts Manual

4W315C

Dayton® Diesel Electric Generator

Specifications

ELECTRICAL SPECIFICATIONS

Rated

Maximum

Rated Amperage

Rated Amperage

Wattage*

VA

120V

240V

5000
6500
41.7
20.8

* Single-phase, 1.0 power factor

NOTE: Ratings apply to SAE standard conditions. Reduce ratings 3 1/2% for each 1000 feet above sea level and 1% for each 10° Fahrenheit rise above 60°F.

GENERAL SPECIFICATIONS

Yanmar

Yanmar

Fuel

Fuel Tank

Oil Alert

Electric

Weight

Engine H.P.

Model

Type

Capacity

System

Start

(pounds)

10

L100
Diesel
4.2 gal.

Yes

Yes

241

RECEPTACLE SPECIFICATIONS

120V

120V, 30-Amp

120/240V, 20-Amp

120V Full

Duplex

Twist-Lock

Twist-Lock

Power Switch

Yes

Yes

Yes

Yes

ELECTRICAL COMPONENT SPECIFICATIONS

 

Resistance in Ohms

 

 

 

Stator

Stator

 

Rotor

Rotor

Capacitor,

 

Main

Auxiliary

Primary

Secondary

MFD

Diodes (2)

Winding *

Winding

Winding †

Winding †

450 Volt

800 Volt

0.54
1.38

 

0.61
2.29

50

70 Amp

(*)Connect T2 (green) and T3 (black). Measure resistance between T1 (red) and T4 (yellow). () Resistance between brown and white leads.

(†) Remove diodes to check resistance.

107358

2

Image 2
Contents Dayton Diesel Electric Generator DescriptionUnpacking 4W315CGENERAL SPECIFICATIONS SpecificationsELECTRICAL SPECIFICATIONS RECEPTACLE SPECIFICATIONSFigure 2 - Portable Generator Model 4W315CProduct Identification Roll CageGeneral Safety Information OIL ALERT SYSTEM General Safety Information ContinuedGenerator Features FULL POWER SELECTOR SWITCH Generator Features ContinuedBATTERY DISCHARGE LAMP GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLERECEPTACLE CIRCUIT BREAKER AssemblyBATTERY SPARK ARRESTERENGINE OIL Assembly ContinuedInstallation FUELGENERATOR GROUNDING Installation ContinuedVENTILATION DUST, DIRT, RAIN, AND SNOWEXTENSION CORDS GROUND FAULT PROTECTIONSTANDBY INSTALLATION TO HOME OR BUILDING DETERMINING ELECTRICAL LOAD FOR GENERATORCHART TYPICAL ELECTRIC APPLIANCE WATTAGESOperation USING RECEPTACLEPOWER CORD AND PLUG REQUIRE- MENTS HIGH AND LOW TEMPERATURE OPERATIONOperation Continued STARTINGHIGH ALTITUDE OPERATION DISCONNECTING ELECTRIC LOADSOperation continued ADDING ELECTRICAL LOADSHOW TO CHANGE YOUR ENGINE OIL Maintenance and RepairsENGINE MAINTENANCE CLEANING THE OIL FILTERCLEANING THE SPARK ARRESTER Maintenance and Repairs ContinuedCLEANING AND REPLACING THE FUEL FILTER StorageStorage Continued ENGINE STORAGEFigure 27 - Engine Wiring Diagram Wiring DiagramsFigure 26 - Alternator Wiring Diagram Possible Causes Troubleshooting ChartSymptom Figure 28 - Repair Parts Illustration for Fuel Tank and Roll Cage 24 hours a day - 365 days a yearDaytonFor Repair Parts, Dieselcall 1-800Electric-323-0620 Generator Part No. for ModelRepair Parts4W315CList for Fuel Tank and Roll CageReference NumberDaytonFor Repair Parts, Dieselcall 1-800Electric-323-0620 Generator Figure 29 - Repair Parts Illustration for Alternator AssemblyModelRepair Parts4W315CList for Alternator Assembly POWER Figure 30 - Repair Parts Illustration for Control PanelRESET 1212ModelRepair Parts4W315CList for Control Panel Figure 31 - Repair Parts Illustration for Switch Control Box ModelRepair Parts4W315CList for Switch Control Box Limited Warranty Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A