Engine

ENGINE SW

SwitchCIRCUIT

BREAKER

ON/push OFF

Figure 24 - Engine Switch (Models

MGH5000DIE, MGH7000D, MGH7000DI,

and MGH10000A Only)

Choke Lever (Open Position)

Note: The 250 Volt/50 Amp receptacle is not connected through the Auto-Idle circuit. The Auto-Idle switch must be turned off to get full power out of this receptacle (see Figure 26).

6.The Auto-Idle system should be turned OFF when generator is shut down.

Adjusting the Idle Speed

IMPORTANT: Adjust the idle speed only:

If the idle speed becomes too high.

If the engine idle speed will not regulate (en- gine idles and speeds up again and again).

1. Turn Auto-Idle switch OFF. Start en-

gine. Allow engine to warm up with no

8.Turn Auto-Idle switch ON. Make sure solenoid is engaged. When engaged, the punger is pulled back into the solenoid.

9.If the engine speed is too slow, the en- gine will want to "hunt" or speed up and slow down repeatedly. When this occurs, increase engine speed by adjust- ing throttle stop screw on carburetor (refer to Carburetor Adjustment in Honda Engine Manual).

10.Replace the engine linkage cover (Models MGH4000CI, MGH5000DI, MGH5000DIE, MGH6000DI, and MGH7000DI).

Solenoid Mounting

Figure 25 - Choke Lever Opened (Model MGH7000D Shown)

AUTO-IDLE OPERATION

IMPORTANT: Never start engine with elec- trical loads connected. Start engine before adding electrical loads.

load for five minutes.

WARNING: Always set the idle speed before turning on the Auto- Idle. If idle speed is not set, the larger resistor on the control board may become hot. Heat from the resistor may damage the protec- tive coating on the control board.

2.

Remove engine linkage cover

 

(Models MGH4000CI, MGH5000DI,

 

MGH5000DIE, MGH6000DI, and

 

MGH7000DI).

3.

Push plunger into solenoid body to manu-

Bracket

ENGINE

OFF

M8 Nut

1.If engine is cold, turn the Auto-Idle switch OFF (see Figure 26).

2.Start engine. Allow engine to warm up with no load for five minutes.

3.Turn Auto-Idle switch ON. Engine will slow to idle speed. Engine idle speed is preset. Idle speed adjustment should not be necessary.

4.Operate generator according to speci- fications outlined in owner's manual.

5.Engine will automatically increase to normal operating speed when you plug load into any generator outlet.

Auto-Idle Switch

120

VOLTS

 

RESET

TEST

 

Auto-

ON

Idle

 

OFF

ENM

 

 

 

HOURS00000005

RESET

240

 

1/10

VOLTS

 

 

 

 

RESET

 

RESET

 

 

 

 

 

 

RESET

Figure 26 - Control Panel

ally engage solenoid and set idle speed.

4. Loosen the M8 nut that holds the sole-

noid mounting bracket to the generator

(Models MGH4000CI, MGH5000DI,

MGH5000DIE, MGH6000DI, and

MGH7000DI. See Figure 27). Do not

loosen bolt that holds the solenoid

mounting bracket to the generator on

Model MGH10000A (see Figure 28).

5. Slowly pull solenoid bracket away from

engine (on Model MGH10000A this will

require bending the bracket slightly).

6. With a volt meter, check the no-load

output voltage at the 120-volt duplex

receptacle. At proper idle speed (2680

minimum RPM) the meter should read

50-60 volts. Lower settings will cause

the Auto-Idle to not operate properly.

7. After reaching proper idle speed,

tighten M8 nut to secure solenoid

mounting

bracket

(Models

MGH4000CI,

MGH5000DI,

MGH5000DIE, MGH6000DI, and

MGH7000DI (see Figure 27).

Figure 27 - Solenoid Bracket Location,

Models MGH4000CI, MGH5000DI,

MGH5000DIE, MGH6000DI, and

MGH7000D Only

Solenoid

Mounting

Bracket

Bolt

Figure 28 - Solenoid Bracket Location, Model MGH10000A Only

106813

13

Image 13
Contents Portable Gasoline Generators Portable Gasoline Generators Safety InformationGfci Product IdentificationGeneral Information High and LOW Temperature OperationUnpacking VentilationMGH5000DI SpecificationsModel MGH3000PR MGH4000CI MGH5000DIE MGH6000DIFull Power Selector Switch Generator FeaturesOIL Alert System AUTO-IDLE SystemFuel Engine OILReceptacle Circuit Breaker Engine Circuit BreakerInstalling Battery Cables to Engine BatteryHandles TOP Cover Recommended Minimum Wire Gauges AWG for Extension Cords Mounting Battery to GeneratorExtension Cords Generator GroundingChart 1 Typical Electric Appliance Wattages Standby Installation to Home or BuildingChart Determining Electrical Load for GeneratorPower Cord and Plug Requirements Using ReceptacleOperation General InformationStarting PrestartAUTO-IDLE Operation Adjusting the Idle SpeedHigh Altitude Operation Adding Electrical Loads Disconnecting Electric LoadsStopping Engine Troubleshooting Maintenance and RepairsStorage Wiring Diagrams Electrical Component SpecificationsWiring Diagram, Model MGH7000D Wiring Diagram, Model MGH7000DI Accessories Technical ServiceReplacement Parts Servicing the EngineFor Models HWI3000, MGH3000 MGH3000PR Alternator Assembly Illustrated Parts ListKEY Part Number Description QTY Parts Available not ShownKEY Part Number for ModelMGH4000CI MGH5000DIE MGH6000DI MGH7000DI Description QTY KEY Part Description Number QTY For Model MGH10000A Alternator AssemblyWP-5C For Models HWI3000, MGH3000 MGH3000PR Roll CagePortable Gasoline Generators MGH4000C MGH5000D MGH6000D MGH7000D Portable Gasoline Generators For Model MGH10000A Fuel Tank and Roll CageWLI-8 Control Panel Reset 120For Model MGH10000A Control Panel For Solenoid and Control Board Assemblies and Mounting Model MGH10000A Only † All Models Except MGH10000A International Keep this Warranty