Kohler Thermostatic Electric Shower manual Maintenance, Handset Cleaning

Page 23

Symptom

Power

Heater

Probable Cause

Possible Remedy

 

Light

Setting

 

 

 

Low/Medium/

 

 

 

 

 

 

 

 

High

 

 

 

 

 

 

 

No change in

ON

Any

Insufficient mains water

Contact local water company.

temperature

 

 

pressure.

 

between Low/

ON

Any

Possible failure of Flow

Use a suitable continuity

Medium/High

setting.

 

 

Valve, Microswitch, or

device to check the continuity

 

 

 

Heater Tank.

of the Microswitch or Heater

 

 

 

 

Tank and replace parts

 

 

 

 

as necessary.

 

 

 

 

 

Water will not

ON

Any

Inlet Valve, Solenoid, or

Replace as necessary.

turn off.

 

 

Start/Stop switch faulty.

 

 

ON

Any

Supply pressure below

Contact local water company.

 

 

 

0.2 bar.

Check mains water static

 

 

 

 

pressure.

 

 

 

 

 

Appliance fails

ON

II/III

Insufficient Water supply.

Contact local water

to produce hot

 

 

 

company.

water when set

ON

II/III

Possible failure of the

Use a suitable continuity

on Medium/

 

 

Microswitch or thermal

device to check the continuity

High Heater

 

 

 

 

switch.

of the Microswitch or Heater

Setting.

 

 

 

 

 

Tank and replace parts as

 

 

 

 

 

 

 

 

necessary.

 

ON

II/III

Heater Tank failure.

Replace.

 

 

 

 

 

Maintenance

Handset - Cleaning

Clean with mild washing up detergent or soap solution. Wipe dry with a soft cloth.

Poor shower performance can be avoided by cleaning the spray plate. Use thumb or soft cloth to wipe rubber nozzles. The handset must be descaled regularly.

23

Image 23
Contents These instructions are to be left with the user Contents Mira Azora 9.8 kW IntroductionImportant Safety Information Page Documentation Pack Contents ChecklistMira Energise Electric Shower Fittings Electrical SpecificationsInstallation Requirements PlumbingShower Tray Electrical Installation Installation of Mira Azora Page = Brown = GREEN/YELLOW N = Blue Page Installation of Shower Fittings End Support Slidebar End 10.11 Commissioning17.18 13.14User Instructions Read the section Important Safety Information first Eco Spray ActionOnly a Competent Tradesperson should Remove the Front Cover Fault DiagnosisHigh Low or No Handset Cleaning MaintenanceRead the section Important Safety Information first Inlet Filter Cleaning/RenewingSpare Parts List Accessories Mira Azora Spare Parts ListMira Azora Spare Parts Diagram Mira Energise Shower Fittings Spare Parts List Dimensions Internal Wiring Diagram Wiring DiagramCustomer Services Mira Showers