Symptom | Power | Heater | Probable Cause | Possible Remedy | |
| Light | Setting |
|
| |
| Low/Medium/ |
|
| ||
|
|
|
| ||
|
| High |
|
| |
|
|
|
|
| |
No change in | ON | Any | Insufficient mains water | Contact local water company. | |
temperature |
|
| pressure. |
| |
between Low/ | ON | Any | Possible failure of Flow | Use a suitable continuity | |
Medium/High | |||||
setting. |
|
| Valve, Microswitch, or | device to check the continuity | |
|
|
| Heater Tank. | of the Microswitch or Heater | |
|
|
|
| Tank and replace parts | |
|
|
|
| as necessary. | |
|
|
|
|
| |
Water will not | ON | Any | Inlet Valve, Solenoid, or | Replace as necessary. | |
turn off. |
|
| Start/Stop switch faulty. |
| |
| ON | Any | Supply pressure below | Contact local water company. | |
|
|
| 0.2 bar. | Check mains water static | |
|
|
|
| pressure. | |
|
|
|
|
| |
Appliance fails | ON | II/III | Insufficient Water supply. | Contact local water | |
to produce hot |
|
|
| company. | |
water when set | ON | II/III | Possible failure of the | Use a suitable continuity | |
on Medium/ | |||||
|
| Microswitch or thermal | device to check the continuity | ||
High Heater |
|
| |||
|
| switch. | of the Microswitch or Heater | ||
Setting. |
|
| |||
|
|
| Tank and replace parts as | ||
|
|
|
| ||
|
|
|
| necessary. | |
| ON | II/III | Heater Tank failure. | Replace. | |
|
|
|
|
|
Maintenance
Handset - Cleaning
Clean with mild washing up detergent or soap solution. Wipe dry with a soft cloth.
Poor shower performance can be avoided by cleaning the spray plate. Use thumb or soft cloth to wipe rubber nozzles. The handset must be descaled regularly.