Kohler Thermostatic Electric Shower manual 13.14, 17.18

Page 18

13.14.

 

5 - 10 Secs

Set control to ‘III’.

The temperature will rise further.

15.

16.

Adjust temperature as required. Flow rate will adjust automatically.

Press STOP and isolate power.

17.18.

0 - 5 Secs

The shower will purge from its tank for a few seconds.

Residual water may drain over a few minutes.

Note! A slight hissing sound may be heard from the appliance during operation. High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use.

18

Image 18
Contents These instructions are to be left with the user Contents Introduction Mira Azora 9.8 kWImportant Safety Information Page Pack Contents Checklist DocumentationMira Energise Electric Shower Fittings Plumbing SpecificationsInstallation Requirements ElectricalShower Tray Electrical Installation Installation of Mira Azora Page = Brown = GREEN/YELLOW N = Blue Page Installation of Shower Fittings End Support Slidebar End Commissioning 10.1113.14 17.18Read the section Important Safety Information first User InstructionsSpray Action EcoFault Diagnosis Only a Competent Tradesperson should Remove the Front CoverHigh Low or No Maintenance Handset CleaningInlet Filter Cleaning/Renewing Read the section Important Safety Information firstSpare Parts List Mira Azora Spare Parts List AccessoriesMira Azora Spare Parts Diagram Mira Energise Shower Fittings Spare Parts List Dimensions Wiring Diagram Internal Wiring DiagramCustomer Services Mira Showers