Kohler 24RCL manual LCD Display, Active Alert

Page 31

3.2.3LCD Display

The controller is equipped with a two-line x 16 character backlit liquid crystal diode (LCD) display with adjustable contrast. When the generator is running, the controller automatically scrolls through the displays shown in Figure 3-4. When the system is in AUTO, the LCD display scrolls through the status messages shown in Figure 3-5.

When a fault or warning condition exists, the controller will show the corresponding message. See Section 2.6 for more information on fault and warning messages.

Controller menus display power system information, including status information for the engine, generator, and optional RBUS accessories, exercise settings, and event history. Some menus allow changes to the controller settings. See Sections 3.6 through 3.19 for menu diagrams.

Active Alert

Genset Status

Running

Voltage: 240V

Freq: 60.0Hz

Engine: 123F

Oil Pressure: 40 psi

Battery

12.3V

Engine Runtime: 27.4 h

Date: 02DEC2014

Time: HR:MNpm

Sample data shown.

tp6810

Figure 3-4Autopaging Displays, Generator Running

The display contrast is adjustable. Navigate to the Genset System menu and step down to the Contrast screen. Press the Select button, and then use the up and down arrow buttons to adjust the contrast. See Section 3.5, Changing Settings, and Section 3.11, Generator Set System Menu.

The display backlight turns off after about a minute of no activity. The backlight turns on when a button is pressed or when the generator set starts.

Genset Status

Standby

Battery

12.3V

Engine Runtime: 27.4 h

Date: 02DEC2014

Time: HR:MNpm

Next Exercise: 09:00p 09Dec2014

Next Maintenance: 150 h or Mar2015

Sample data shown.

tp6810

Figure 3-5Autopaging Displays, Automatic Mode

TP-6905 6/14

Section 3 RDC2 Controller Operation 31

Image 31
Contents TP-6905 6/14 RDC2Generator Set Identification Numbers Accessory Number Accessory DescriptionProduct Identification Information Controller IdentificationTable of Contents Troubleshooting Scheduled MaintenanceAppendix a Abbreviations Accidental starting Can cause severe injury or death Safety Precautions and InstructionsBattery Accidental StartingExhaust System Engine Backfire/Flash FireFuel System Airborne particles Can cause severe injury or blind- ness Hazardous NoiseHazardous noise Can cause hearing loss Hazardous voltage Will cause severe injury or deathHot coolant and steam Can cause severe injury or death Hot PartsNameplate IntroductionLiterature Type Part Number List of Related LiteratureService Assistance Service Assistance TP-6905 6/14 Cooling System Detail Service ViewsService Views TP-6905 6/14 Keep the generator set area clear. Maintain at least Prestart ChecklistGenerator Set Operation Operating AreaGenerator Set Operation Exercising the Generator SetExercise Automatic Operation with Model RDT or RSB Transfer SwitchesUnloaded Cycle Exercise with Complete System Diagnostics System DiagnosticsUnloaded Full-Speed Exercise Power Failure During ExerciseExerciser Reset Setting the Exerciser at Power-upProcedure to Change the Exercise Setting Changing the Exercise Setting2RDC2 Main Menu 3Procedure to Set the Exerciser Procedure to Reset the Controller after a Fault Shutdown FaultsATS Communication Errors Resetting the Controller after a Fault ShutdownATS Fault RDC2 Fault OnCuer Condition Check PlusECM Air filter 5Controller Fault Messages Event Log Model RXT Transfer Switch OperationProcedure to View Event History SettingNormal Source Fails Time DelaysATS Load Control Relay Time Delay ATS Control Sequence of OperationRDC2 Controller Operation Controls and IndicatorsLED Operation Controller Keypad LED IndicatorsButton Button FunctionActive Alert LCD DisplayProcedure to Change Settings Controller PowerBattery Charging Changing Settings6Changing Settings Changing Settings on the RDC2 ControllerMain Menu Controller MenusEngine Metering Menu Overview MenuVoltage Calibration Generator Metering MenuGenset Run Time Menu Generator Set Information MenuGenset System Menu Voltage Regulator VR Voltage AdjustSetting the Exerciser Adjusting the Display ContrastScreens on this page do not appear ATS Status MenuChanging ATS Configuration Settings ATS Configuration MenuDate and Time 02Dec2014 1234pm Time Format 12hr24hr Date and Time Menu17Networking Information Menu Networking Information MenusDhcp Networking Status SubmenuOnCue Plus Password Networking Configuration Submenu OnCue Plus Password20RBUS Information Submenu Rbus Information Submenu21Remote Devices Submenu Remote Devices SubmenuProgrammable Interface Module PIM Menus 23Load Control Status Menu Load Control MenusGeneral Maintenance Scheduled MaintenanceScheduled Maintenance TP-6905 6/14 Service Schedule Oil Additions Oil SpecificationsLubrication System Oil CheckCheck for leaks Reset the maintenance timer on the RDC2Replace the oil filter Stop the generator set. Check the oil level. AddAir Cleaner Service Procedure Air CleanerChecking and Filling Coolant Cooling SystemExhaust System Inspection Points Draining Cooling System Flushing and CleaningFlushing and Cleaning Procedure Cooling System InspectionModel Spark plug gap Ignition System511 Battery Storage Procedure USB Port TroubleshootingFault Messages IntroductionProblem Possible Cause Corrective Action Generator Set Troubleshooting2RDC2 Troubleshooting Chart Controller TroubleshootingTroubleshooting TP-6905 6/14 Ansi Appendix a AbbreviationsLCB Page By Kohler Co. All rights reserved

24RCL specifications

The Kohler 24RCL is a powerful, compact generator designed to provide reliable backup power for residential applications. Equipped with a robust 24 kW output, this generator is engineered for both efficiency and durability, making it an excellent choice for homeowners looking to safeguard their property against outages.

One of the standout features of the Kohler 24RCL is its quiet operation. With a noise level significantly lower than that of traditional generators, it allows homeowners to maintain their comfort without the disruptive sounds often associated with backup power systems. This is particularly important in residential neighborhoods where maintaining peace and quiet is essential.

The generator is powered by a liquid-cooled Kohler engine, which ensures consistent performance and longevity. Liquid-cooled engines are known for their ability to provide better thermal management, thereby extending the life of the engine while also improving efficiency. Moreover, the Kohler 24RCL utilizes a proven design that enables quick starts and reliable operation, even in the most challenging conditions.

Another key technology in the 24RCL is its integrated transfer switch, which automatically detects power outages and switches the home’s electrical supply to the generator. This seamless transition ensures that there is no disruption in power, making it an ideal solution for critical loads such as refrigerators, medical equipment, and security systems. The generator’s advanced control system allows for easy monitoring and maintenance, providing users with peace of mind whenever they rely on their backup power.

The Kohler 24RCL boasts a weather-resistant enclosure, designed to withstand the elements and provide protection against rain, snow, and harsh winds. This rugged construction also contributes to the longevity of the unit, ensuring that it can perform reliably year after year.

Sustainability is another driving factor in the design of the Kohler 24RCL. The generator features efficient fuel consumption, which not only helps to reduce operating costs but also minimizes the environmental impact. With many homeowners increasingly focused on eco-friendly solutions, the 24RCL fits seamlessly into a sustainable lifestyle.

Overall, the Kohler 24RCL is a powerful, efficient, and quiet backup generator that combines advanced technology with rugged reliability. Its features make it a standout choice for homeowners seeking a dependable power solution that prioritizes convenience, safety, and sustainability. Whether facing severe weather or unexpected outages, the Kohler 24RCL ensures that homes remain powered and protected.