Generac Power Systems 004916-0 owner manual Installation Diagram

Page 23

826

[32.54"]

1797 [70.76"]

TOP VIEW

(WITH ROOF OPEN)

"DO NOT LIFT BY THE ROOF"

1219 [48.00"]

FRONT VIEW

**ALL DIMENSIONS IN:

MILLIMETERS [INCHES]

790

[31.09"]

76.2[3.00"]

PEA GRAVEL

MINUMUM

AIR

OUTLET

1219

[47.98"]

SWING ARC OF

SERVICE DOOR

914 [36.00"]

RIGHT SIDE VIEW

(SERVICE DOOR OPEN)

3/4" NPT FUEL INLET - REQUIRED FUEL PRESSURE: NATURAL GAS = 5-7" WATER COLUMN

LIQUID PROPANE (VAPOR) = 10-12" WATER COLUMN

468

[18.43"]

457

[18.00"]

AIR INTAKE

914mm [ 36.0" ]

MINIMUM OPEN AREA

ALL AROUND UNIT

ACCESS TO OUTPUT CIRCUIT BREAKER AND TRANSFER SWITCH CONNECTIONS (REMOVE PLUG FOR ACCESS)

GROUNDING LUG

LIFTING HOLES 4-CORNERS

REAR VIEW

Air-cooled 11 kW Generators Installation Diagram – Drawing No. 0E7612-A

Section 6 — Installation Diagram

21

Image 23
Contents Installation Authorized Dealer Location IntroductionTroubleshooting  Warning  ‹ Standards Index  Electrical Hazards System SET LED Accessory FeaturesUNPACKING/INSPECTION Protection Systems‹ 1.4.2 120 Volt AC Outlet Generator‹ 1.6.2 Engine Specifications‹ 1.6.1 Generator Location Reconfiguring Fuel SystemFuel Requirements Recommendations Fuel Consumption‹ 1.10.2 Transfer Switch Battery InstallationBattery Before Initial START-UP Check Transfer Switch OperationElectrical Checks Checking Automatic Operation Generator Tests Under Load‹ 3.2.1 Auto Position Voltage Regulator AdjustmentBREAK-IN Procedure ‹ 3.2.3 Manual Position Automatic Transfer OperationSequence of Automatic Operation ‹ 3.2.2 OFF Position‹ 3.6.3 Overcrank Setting the Exercise Timer‹ 3.6.1 LOW OIL Pressure Switch ‹ 3.6.2 High Temperature SwitchChanging the Engine OIL ‹ 3.6.5 LOW BatterySystem Fuse Checking the Engine OIL LevelSpark Plugs Changing the Engine AIR Cleaner‹ 4.3.2 OIL Change Procedure Changing the OIL FilterAdjusting GT-990 Valve Clearance Battery MaintenanceCooling System OUT of Service Procedure‹ 4.12.1 Removal from Service Corrosion Protection‹ 4.12.2 Return to Service Be performed by the nearest Authorized Dealer Service ScheduleProblem Cause Correction Troubleshooting GuideInstallation Diagram Control Panel BOX Customer Connection Charger Engine Alternator Exploded Views and Parts Lists Part NO. QTY Description Air-cooled 11 kW Generators Control Panel Drawing No E4879-D ASSEMBLY, Home Standby Exploded Views and Parts Lists QTY Description 102 Screw Hhtt M6-1.0 X 10 YC Alternator Air-cooled Pulleys Drawing KW Generators No E4880 FRAME, Mounting SS HSB Air-cooled 11 kW Generators Regulator Drawing No E4881-C CASTING, Twin Regulator Housing Air-cooled 11 kW Generators Air-cooled 11 kW Generators PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power SYSTEMS, INC

004916-0 specifications

Generac Power Systems 004916-0 is a robust and efficient solution for home and commercial power needs, designed to provide reliable electricity during outages and emergencies. This model is a standout generator, well-regarded for its technology and features that cater to users looking for both performance and dependability.

One of the main features of the 004916-0 is its powerful engine. It is equipped with a Generac G-Force engine, which is engineered for durability and high performance. This engine provides a reliable source of power, ensuring that homes and businesses can maintain essential functions during power interruptions. Its impressive starting capability and consistent performance make it a trusted choice for many users.

The generator also boasts an automatic transfer switch, which facilitates a smooth transition to generator power when the grid goes down. This feature minimizes disruption, as it ensures that critical systems like refrigeration, heating, and medical equipment remain operational without manual intervention. The transfer switch allows the generator to kick in within seconds of detecting a power loss, providing peace of mind for users.

In terms of technology, the 004916-0 incorporates advanced features such as Mobile Linkā„¢ remote monitoring. This innovative technology allows users to monitor the status of their generator from anywhere via a smartphone or tablet. Users can easily check power levels, receive maintenance alerts, and ensure that their system is running efficiently, providing enhanced control and convenience.

Another notable characteristic is its innovative enclosure design, which minimizes noise during operation. This makes the 004916-0 suitable for residential areas where noise pollution can be a concern. The generator's sound-dampening technology ensures that it operates quietly, providing a more pleasant environment for users and neighbors alike.

Additionally, the generator is built with user-friendly controls, allowing for easy start-up and operations. The intuitive interface simplifies monitoring and adjustments, making it accessible even for those who may not be technically inclined.

Generac Power Systems 004916-0 represents a blend of power, reliability, and advanced technology, making it a top choice for anyone seeking a dependable backup power solution. Its features are designed to meet the challenges of modern power outages, offering users the comfort and security they need in times of uncertainty. Whether for home or business use, the 004916-0 stands out as a reliable partner in power management.