Generac Power Systems 004916-0 owner manual ASSEMBLY, Home Standby

Page 31

 

 

 

 

Section 8 — Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air-cooled 11 kW Generators

 

 

 

 

 

 

 

 

Control Panel – Drawing No. 0E4879-D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

PART NO. QTY.

DESCRIPTION

 

ITEM

PART NO. QTY.

DESCRIPTION

 

1

0E3312

1

ASSEMBLY, HOME STANDBY

34

0D8502

1

NEUTRAL ISOLATOR

 

 

 

 

CONTROLLER

35

045770

2

SCREW HHC M5-0.8 X 10mm

2

0A1801

1

ASSEMBLY, BATTERY CHARGER ENGINE

36

075475

4

SCREW PPHM M4-0.7 X 10mm

3

083049

1

ASSEMBLY, POTTED REGULATOR

37

049721

1

SCREW HHC M6-1.0 X 35mm

4

092036

8

PPHM S/LW #6-32 X 1/4" LONG

38

038750

1

SCREW HHC M6-1.0 X 30mm

5

0D3062A

4

HEX STAND-OFF #6-32 X 3/4"

39

049813

4

NUT HEX M6 X 1.0

6

075235

4

SCREW HHC M5-0.8 X 30mm

40

054502

1

CIRCUIT BREAKER 3 X 1

7

049226

6

WASHER LOCK M5

41

075210A

1

BLOCK 1 POSITION

8

051716

6

NUT HEX M5-0.8

42

0C1085

4

SCREW PPHM M3-0.5 X 8mm

9

023484D

2

SNAP BUSHING 0.875"

43

0C3910

1

TRANSFORMER

10

0E4387

1

CONTROL, PANEL

44

043180

2

WASHER FLAT M4

11

032300

2

HOLDER FUSE

45

0C2174

1

RELAY 12V 25A SPST

12

022676

1

FUSE, 15AMP X AGC15

46

031879

4

WASHER FLAT #4

13

0A9611

1

FUSE, 7.5AMP X AGC7.5

47

043182

4

WASHER LOCK M3

14

0E3928

1

SWITCH, ROCKER SPST (ON)-OFF N/C

48

051714

4

NUT HEX M3-0.5

15

0E4494

1

SWITCH ROC DPDT ON-OFF-ON

49

063617

1

RELAY PANEL 12VDC DPDT 10A 240VAC

16

074908

13

SCREW HHTT M5-0.8 X 10mm

50

036903

6

SCREW PPHM #6-32 X 5/8"

17

0E4806

1

COVER, CONTROL PANEL RIGHT

51

0A1658

2

WASHER LOCK SPECIAL 1/4"

18

0E5206

1

COVER, CONTROL PANEL LEFT

52

059636

4

PLASTITE PH #4 X 0.37"

19

0E6045

1

COVER, CONNECTION BOX

53

0E5280

1

BRACKET, PCB HEADER SUPPORT

20

045756

7

SCREW HHTT M6-1.0 X 10mm

54

0E6553

1

ISOLATOR/SHOULDER WASHER NYLON

21

0E6044

1

CONNECTION BOX

55

0E6553A

1

WASHER NYLON 0.50" X 0.32" X 0.12"

22

096021

2

GROMMET 0.75" X 0.06" X 0.50"

56

0912970063

1

GROUND WIRE

23

046689

1

TERMINAL STRIP

57

082625

4

NUT LOCK HEX #6-32 NYL INSERT

24

051715

8

NUT HEX M4-0.7

58

0E4381

1

PANEL, TOP COMPARTMENT

25

022264

8

WASHER LOCK #8-M4

59

0E5840

1

CIRCUIT BREAKER 15A PUSH / PULL

26

075476

4

SCREW PPHM M4-0.7 X 16mm

 

 

 

 

MAIN RESET

27

0E7886D

1

CIRCUIT BREAKER

60

0E4261

1

OUTLET, 15A GFCI DUPLEX

28

023897

2

WASHER FLAT #10

61

0E7833

1

PLATE, WEATHERPROOF GFCI

29

0E7890

1

CIRCUIT BREAKER MOUNTING

62

022985

4

WASHER FLAT #6

 

 

 

 

BRACKET

63

0E9056

1

SOCKET, 12VDC ACCESSORY

30

083512

1

SCREW HHTT M8-1.2 X 16mm

64

0912970064

1

GROUND WIRE

31

022507

2

SCREW HHC 1/4"-20 X 1/2" LONG

65

0E9171

1

GASKET, WEATHERPROOF GFCI

32

022097

4

WASHER LOCK M6-1/4"

66

043182

4

WASHER LOCK M3

33

022473

10

WASHER FLAT 1/4"-M6

 

 

 

 

 

 

 

 

 

29

Image 31
Contents Installation Authorized Dealer Location IntroductionTroubleshooting  Warning  ‹ Standards Index  Electrical Hazards System SET LED Accessory FeaturesUNPACKING/INSPECTION Protection Systems‹ 1.4.2 120 Volt AC Outlet Generator‹ 1.6.1 Generator Specifications‹ 1.6.2 Engine Location Reconfiguring Fuel SystemFuel Requirements Recommendations Fuel ConsumptionBattery Battery Installation‹ 1.10.2 Transfer Switch Electrical Checks Check Transfer Switch OperationBefore Initial START-UP Checking Automatic Operation Generator Tests Under LoadBREAK-IN Procedure Voltage Regulator Adjustment‹ 3.2.1 Auto Position ‹ 3.2.3 Manual Position Automatic Transfer OperationSequence of Automatic Operation ‹ 3.2.2 OFF Position‹ 3.6.3 Overcrank Setting the Exercise Timer‹ 3.6.1 LOW OIL Pressure Switch ‹ 3.6.2 High Temperature SwitchChanging the Engine OIL ‹ 3.6.5 LOW BatterySystem Fuse Checking the Engine OIL LevelSpark Plugs Changing the Engine AIR Cleaner‹ 4.3.2 OIL Change Procedure Changing the OIL FilterAdjusting GT-990 Valve Clearance Battery MaintenanceCooling System OUT of Service Procedure‹ 4.12.1 Removal from Service Corrosion Protection‹ 4.12.2 Return to Service Be performed by the nearest Authorized Dealer Service ScheduleProblem Cause Correction Troubleshooting GuideInstallation Diagram Control Panel BOX Customer Connection Charger Engine Alternator Exploded Views and Parts Lists Part NO. QTY Description Air-cooled 11 kW Generators Control Panel Drawing No E4879-D ASSEMBLY, Home Standby Exploded Views and Parts Lists QTY Description 102 Screw Hhtt M6-1.0 X 10 YC Alternator Air-cooled Pulleys Drawing KW Generators No E4880 FRAME, Mounting SS HSB Air-cooled 11 kW Generators Regulator Drawing No E4881-C CASTING, Twin Regulator Housing Air-cooled 11 kW Generators Air-cooled 11 kW Generators MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power SYSTEMS, INC

004916-0 specifications

Generac Power Systems 004916-0 is a robust and efficient solution for home and commercial power needs, designed to provide reliable electricity during outages and emergencies. This model is a standout generator, well-regarded for its technology and features that cater to users looking for both performance and dependability.

One of the main features of the 004916-0 is its powerful engine. It is equipped with a Generac G-Force engine, which is engineered for durability and high performance. This engine provides a reliable source of power, ensuring that homes and businesses can maintain essential functions during power interruptions. Its impressive starting capability and consistent performance make it a trusted choice for many users.

The generator also boasts an automatic transfer switch, which facilitates a smooth transition to generator power when the grid goes down. This feature minimizes disruption, as it ensures that critical systems like refrigeration, heating, and medical equipment remain operational without manual intervention. The transfer switch allows the generator to kick in within seconds of detecting a power loss, providing peace of mind for users.

In terms of technology, the 004916-0 incorporates advanced features such as Mobile Linkā„¢ remote monitoring. This innovative technology allows users to monitor the status of their generator from anywhere via a smartphone or tablet. Users can easily check power levels, receive maintenance alerts, and ensure that their system is running efficiently, providing enhanced control and convenience.

Another notable characteristic is its innovative enclosure design, which minimizes noise during operation. This makes the 004916-0 suitable for residential areas where noise pollution can be a concern. The generator's sound-dampening technology ensures that it operates quietly, providing a more pleasant environment for users and neighbors alike.

Additionally, the generator is built with user-friendly controls, allowing for easy start-up and operations. The intuitive interface simplifies monitoring and adjustments, making it accessible even for those who may not be technically inclined.

Generac Power Systems 004916-0 represents a blend of power, reliability, and advanced technology, making it a top choice for anyone seeking a dependable backup power solution. Its features are designed to meet the challenges of modern power outages, offering users the comfort and security they need in times of uncertainty. Whether for home or business use, the 004916-0 stands out as a reliable partner in power management.