Generac Power Systems 004709-0 owner manual Gasoline Fuel System, ‹ 2.3.2 Testing the Installation

Page 29

‹2.3.2 TESTING THE INSTALLATION

The manufacturer recommends testing the installa- tion to be sure adequate cooling airflow is available to the unit before placing the unit into service. If the unit shows signs of overheating, enlarge the air openings. Never place a unit into service until absolutely certain that cooling and ventilation is adequate.

NOTE:

Test the installation, especially if bringing in air from below the generator set.

2.4 GASOLINE FUEL SYSTEM

The installation of a gasoline fuel system (Figure 2.10) for a recreational vehicle generator set must comply with applicable codes, standards and regula- tions. The entire fuel system must be completely free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior.

Figure 2.10 – Generator Fuel System

Section 2 – Installation

Recreational Vehicle Generator

‹2.4.1 FUEL TANK

Either the generator must share the vehicle engine's fuel tank, or install a separate fuel tank for the generator set. All fuel tanks installed on the vehicle must be constructed, installed and restrained so they comply with applicable codes, standards and regula- tions.

If the generator is to share the vehicle engine's tank, separate fuel pickup tubes are required for the engine and the generator. The manufacturer recommends that the fuel pickup tube be 2 to 3 inches (51 to 76

mm)shorter than the vehicle engine's pickup tube. This prevents the generator from depleting the entire fuel supply during prolonged generator operating periods.

Do NOT tee the generator fuel supply line

into the vehicle engine fuel supply line. If this

is done, the generator will be starved of fuel

when both engines are operating at the same

time. Also, while the vehicle engine is not run-

ning, generator operation may drain the vehicle

GENERAC

OHVIPOWERED

I

G E N E R A C P o w e r S y s t e m s , I n c .- W h it ew a t e r , W

 

GENERAC OHVI INDUSTRIAL ENGINE

QUIETPACT 40G

RV SERVICE LOCATOR: 1.800.333.1322

To Re

m

o v e

CONTROL CENTER

S T A R T

F U E L

C . B .

3 0 A

S T O P

P R I M E

 

 

F U S E

 

 

7.5 A

 

S E R V IC E A C C E S S P A N E L

MAINTENANCE SCHEDULE

REPLACEMENT INFORMATION

TEMPERATURE

SAE VISCOSITY

engine supply line, making it difficult to start

the vehicle engine.

‹2.4.2 GENERATOR FUEL SUPPLY LINE

2.4.2.1 Rigid Fuel Lines

Those lines used to supply fuel from a tank to the generator must comply with applicable codes, stan- dards and regulations. The following general rules apply to rigid fuel lines:

Fuel Pump & Fuel Filter

(Behind Access Panel & Air Filter)

DANGER

Gasoline is highly flammable, and its vapors are explosive. Comply with all codes, standards and regulations pertaining to gasoline fuel systems used in recreational vehicle generators. Properly install and maintain the fuel system and keep it entirely free of leaks. Gasoline vapors must not enter the vehicle interior.

Factory installed generator fuel system components include (a) fuel filter, (b) 12-volt DC electric pump,

(c)engine carburetor, and (d) interconnecting lines and fittings. Connect a fuel supply line to the fuel filter inlet. Use a flexible length of approved fuel hose between the fuel filter inlet connection and rigid fuel lines.

Rigid lines should be of annealed, seamless, drawn aluminum or steel.

Lines and fittings must comply with SAE J512F, “Standard Automotive Fittings,” or with ANSI B126.26 (latest edition).

Route the fuel line so that at least 2 inches (51 mm) of clearance is maintained between the line and any exhaust system parts.

Do not attach electrical wiring to fuel lines. Route the wiring so it cannot come into contact with any fuel line.

Route fuel lines so if they leak, fuel does not drip onto any electrical or exhaust system parts.

Use nonferrous metal straps without sharp edges to secure fuel lines.

27

Image 29
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart Part II Installation Instructions Warning   Fire Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationSpecifications SafetyGenerator Applicability ‹ 1.5.1 Fuel RequirementsFuel Consumption ‹ 1.5.5 GeneratorEngine OIL Requirements ‹ 1.5.6 Emissions Compliance PeriodBefore Starting the Engine Generator Control PanelAutomatic Choke ‹ 2.4.2 Engine Lubrication Starting the Generator‹ 2.4.3 Fuel Supply ‹ 2.4.4 Cooling and Ventilating AIRDo not Overload the Generator Protection Systems Stopping the GeneratorApplying Loads to Generator ‹ 2.9.3 Field Boost Additional Information‹ 2.9.4 Overvoltage Protection ‹ 2.10.2 Operation in High Grass or BrushChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL Level‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerClean AIR Intake Fuel Filter Clean Spark ArrestorCleaning the Generator OUT of Service Procedure Battery Maintenance‹ 3.12.1 Removal from Service Exercising the Generator‹ 3.12.2 Return to Service Adjusting Valve ClearanceRV Generator Service Interval Recreational Vehicle Generator Part  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Major Features and Dimensions Drawing No D8716-J ‹ 2.1.2 Generator Support Location and Support‹ 2.1.1 Generator Location ‹ 2.1.4 Generator Restraint Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.3.1 Generator Airflow ‹ 2.2.5 Compartment Floor CutoutsCompartment Floor Cutout Drawing 0G3723-A Gasoline Fuel System ‹ 2.3.2 Testing the Installation‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply Line‹ 2.5.1 Spark Arrestor Exhaust SystemFlexible Fuel Line Electrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.6.4 Conduit ‹ 2.6.5 Isolating Different Power Sources‹ 2.6.6 Power Supply Cord ‹ 2.7.2 Battery Cables Battery Installation‹ 2.7.1 Recommended Battery ‹ 2.7.3 Battery Cable Connections Optional Accessories‹ 2.7.4 Battery Compartment ‹ 2.8.1 Remote START/STOP PanelTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No D8352-K Part NO. QTY Description Recreational Vehicle Generator Generator Drawing No D8353-L QTY Description Exploded Views and Parts Lists QTY Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004709-0 specifications

Generac Power Systems has established itself as a leader in the home backup generator market with its innovative products, and the Generac 004709-0 is no exception. Designed for homeowners seeking reliable power solutions during outages, this generator ensures peace of mind and uninterrupted operation for essential appliances and electronics.

One of the primary features of the Generac 004709-0 is its robust power output. With a powerful 7,500 running watts and a surge capacity of 9,000 watts, it can efficiently handle large loads, including central air conditioning units, refrigerators, and heat pumps. This generator operates on gasoline, providing an accessible fuel source readily available at most retail locations.

Equipped with a durable 420cc engine, the 004709-0 combines efficiency with exceptional performance. It features a low-oil shutdown system, which safeguards the engine from damage by automatically shutting off when oil levels become critically low. This feature ensures longevity and reliability, making it a dependable choice for homeowners.

The portability of the Generac 004709-0 is another notable characteristic. Weighing approximately 130 pounds, it comes with a built-in handle and sturdy wheels for easy transportation. This feature allows users to move the generator effortlessly from storage to the desired location, which is especially convenient during an emergency.

In addition to power and portability, the Generac 004709-0 boasts user-friendly controls. The control panel includes four 120V household outlets, a 12V automotive outlet, and a circuit breaker, offering flexibility for various connections. Furthermore, the generator is equipped with an easy-to-read fuel gauge and a low-fuel warning light, enhancing operational visibility.

Safety is also paramount in the design of this generator. It includes a powerful muffler that significantly reduces noise and meets stringent regulations for operation in residential areas. Additionally, the 004709-0 incorporates advanced technologies like the PowerDial which allows users to select the correct power level needed for various tasks easily.

Overall, the Generac Power Systems 004709-0 stands out due to its powerful output, user-friendly design, and safety features. Homeowners can rely on this generator to keep their homes powered during outages, ensuring comfort and security for themselves and their families. With its combination of innovation and practicality, the 004709-0 continues to exemplify Generac's commitment to quality and excellence in power solutions.