Generac Power Systems 004709-0 owner manual Battery Installation, ‹ 2.7.1 Recommended Battery

Page 33

Section 2 – Installation

Recreational Vehicle Generator

Figure 2.15 – Installation With Isolation Receptacle

‹2.6.7 GROUND FAULT CIRCUIT INTERRUPTERS

The National Electrical Code (NFPA 70, 551-7) requires that ground fault circuit interrupters (GFCIs) be installed on all external and some internal electri- cal receptacles. Contact the dealer for recommenda- tions.

2.7 BATTERY INSTALLATION

‹2.7.1 RECOMMENDED BATTERY

Install a battery that meets the following require- ments:

The battery must be a 12-volt, automotive type storage battery.

For prevailing ambient temperatures above 32° F (0° C), use a battery rated 70 amp-hours and capable of delivering 400 cold-cranking amperes.

For prevailing ambient temperatures below 32° F (0° C), use a battery rated 95 amp-hours and capable of delivering 400 cold-cranking amperes.

NOTE:

‹2.7.2 BATTERY CABLES

Using battery cables that are too long or too small in diameter may cause a drop in voltage, which causes starting problems. For the best cold weather starting, the voltage drop between battery terminals and the generator connection point should not exceed 0.12 volts per 100 amperes of cranking current.

These generators are rated at about 100 DC amperes of cranking current.

Select battery cables based on (a) cable length and

(b)prevailing ambient temperatures. Generally, the longer the cable and the colder the weather, the larger the cable size must be, as shown in the chart.

 

CABLE LENGTH

 

 

 

in Feet (Meters)

CABLE SIZE

 

 

0 to 10 (0 to 3)

2*

 

 

11 to 15 (3.4 to 4.5)

0

 

 

16 to 20 (4.5 to 6)

000

 

* For warm weather, use No. 2 cable up to 20 feet.

If the battery is to be used to power other vehicle accessories, as well as start the generator, a bat- tery with a larger capacity may be needed.

31

Image 33
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart Part II Installation Instructions Warning   Fire Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationSpecifications SafetyGenerator Applicability ‹ 1.5.1 Fuel RequirementsFuel Consumption ‹ 1.5.5 GeneratorEngine OIL Requirements ‹ 1.5.6 Emissions Compliance PeriodGenerator Control Panel Automatic ChokeBefore Starting the Engine ‹ 2.4.2 Engine Lubrication Starting the Generator‹ 2.4.3 Fuel Supply ‹ 2.4.4 Cooling and Ventilating AIRStopping the Generator Applying Loads to GeneratorDo not Overload the Generator Protection Systems ‹ 2.9.3 Field Boost Additional Information‹ 2.9.4 Overvoltage Protection ‹ 2.10.2 Operation in High Grass or BrushChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelMaintaining the Engine AIR Cleaner Clean AIR Intake‹ 3.3.1 Cleaning the Foam Precleaner Clean Spark Arrestor Cleaning the GeneratorFuel Filter OUT of Service Procedure Battery Maintenance‹ 3.12.1 Removal from Service Exercising the GeneratorAdjusting Valve Clearance RV Generator Service Interval‹ 3.12.2 Return to Service Recreational Vehicle Generator Part  General Hazards   Fire Hazards  Purpose and Scope Manual Equipment DescriptionStandards Booklets Major Features and Dimensions Drawing No D8716-J Location and Support ‹ 2.1.1 Generator Location‹ 2.1.2 Generator Support ‹ 2.1.4 Generator Restraint Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.3.1 Generator Airflow ‹ 2.2.5 Compartment Floor CutoutsCompartment Floor Cutout Drawing 0G3723-A Gasoline Fuel System ‹ 2.3.2 Testing the Installation‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply LineExhaust System Flexible Fuel Line‹ 2.5.1 Spark Arrestor Electrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.6.5 Isolating Different Power Sources ‹ 2.6.6 Power Supply Cord‹ 2.6.4 Conduit Battery Installation ‹ 2.7.1 Recommended Battery‹ 2.7.2 Battery Cables ‹ 2.7.3 Battery Cable Connections Optional Accessories‹ 2.7.4 Battery Compartment ‹ 2.8.1 Remote START/STOP PanelTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No D8352-K Part NO. QTY Description Recreational Vehicle Generator Generator Drawing No D8353-L QTY Description Exploded Views and Parts Lists QTY Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004709-0 specifications

Generac Power Systems has established itself as a leader in the home backup generator market with its innovative products, and the Generac 004709-0 is no exception. Designed for homeowners seeking reliable power solutions during outages, this generator ensures peace of mind and uninterrupted operation for essential appliances and electronics.

One of the primary features of the Generac 004709-0 is its robust power output. With a powerful 7,500 running watts and a surge capacity of 9,000 watts, it can efficiently handle large loads, including central air conditioning units, refrigerators, and heat pumps. This generator operates on gasoline, providing an accessible fuel source readily available at most retail locations.

Equipped with a durable 420cc engine, the 004709-0 combines efficiency with exceptional performance. It features a low-oil shutdown system, which safeguards the engine from damage by automatically shutting off when oil levels become critically low. This feature ensures longevity and reliability, making it a dependable choice for homeowners.

The portability of the Generac 004709-0 is another notable characteristic. Weighing approximately 130 pounds, it comes with a built-in handle and sturdy wheels for easy transportation. This feature allows users to move the generator effortlessly from storage to the desired location, which is especially convenient during an emergency.

In addition to power and portability, the Generac 004709-0 boasts user-friendly controls. The control panel includes four 120V household outlets, a 12V automotive outlet, and a circuit breaker, offering flexibility for various connections. Furthermore, the generator is equipped with an easy-to-read fuel gauge and a low-fuel warning light, enhancing operational visibility.

Safety is also paramount in the design of this generator. It includes a powerful muffler that significantly reduces noise and meets stringent regulations for operation in residential areas. Additionally, the 004709-0 incorporates advanced technologies like the PowerDial which allows users to select the correct power level needed for various tasks easily.

Overall, the Generac Power Systems 004709-0 stands out due to its powerful output, user-friendly design, and safety features. Homeowners can rely on this generator to keep their homes powered during outages, ensuring comfort and security for themselves and their families. With its combination of innovation and practicality, the 004709-0 continues to exemplify Generac's commitment to quality and excellence in power solutions.