Generac Power Systems 004709-0 owner manual  Warning 

Page 4

Safety Rules

Recreational Vehicle Generator

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe

operation be copied and posted in potential hazard areas of the recreational vehicle. Safety should be stressed to all operators and potential operators of this equipment.

• WARNING:

The engine exhaust from this product contains

chemicals known to the state of California to cause cancer, birth defects or other reproductive harm.

• WARNING:

This product contains or emits chemicals known

to the state of California to cause cancer, birth defects or other reproductive harm.

Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this manual and with the unit. The gen- erator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.

The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit, are, therefore, not all-inclusive. If using a procedure, work method or operating technique the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique uti- lized does not render the generator unsafe.

DANGER

Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot during operation. Exercise care near running generators.

GENERAL HAZARDS

For safety reasons, the manufacturer recommends that the installation, initial start-up and main- tenance of this equipment is carried out by an Authorized Service Dealer.

The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentra- tions, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently, (b) nausea,

(c)vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weak- ness, and (i) sleepiness. IF EXPERIENCING ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired.

Never sleep in the vehicle while the genset is run- ning unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area.

The engine exhaust fumes contain carbon monox- ide, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. This exhaust system must be installed properly, in strict com- pliance with applicable codes and standards. Following installation, do nothing that might ren- der the system unsafe or in noncompliance with such codes and standards. The generator com- partment must be completely vapor sealed from the vehicle interior. There must be no possibility of exhaust fumes entering the vehicle interior. Never operate this equipment with a leaking or defective exhaust system.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and ven- tilating air is critical to correct generator opera- tion and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or permit even partial blockage of ventilation provi- sions, as this can seriously affect safe operation of the generator.

2

Image 4
Contents Air-cooled Recreational Vehicle Generators Authorized Service Dealer Location IntroductionPart II Installation Instructions Part Warning   Fire Hazards  Generator Identification Model Number Serial Number KW Rating Rated VoltageSafety SpecificationsGenerator Applicability ‹ 1.5.1 Fuel Requirements‹ 1.5.5 Generator Fuel ConsumptionEngine OIL Requirements ‹ 1.5.6 Emissions Compliance PeriodAutomatic Choke Generator Control PanelBefore Starting the Engine Starting the Generator ‹ 2.4.2 Engine Lubrication‹ 2.4.3 Fuel Supply ‹ 2.4.4 Cooling and Ventilating AIRApplying Loads to Generator Stopping the GeneratorDo not Overload the Generator Protection Systems Additional Information ‹ 2.9.3 Field Boost‹ 2.9.4 Overvoltage Protection ‹ 2.10.2 Operation in High Grass or BrushChecking the Engine OIL Level Changing the Engine OIL AND/OR OIL FilterClean AIR Intake Maintaining the Engine AIR Cleaner‹ 3.3.1 Cleaning the Foam Precleaner Cleaning the Generator Clean Spark ArrestorFuel Filter Battery Maintenance OUT of Service Procedure‹ 3.12.1 Removal from Service Exercising the GeneratorRV Generator Service Interval Adjusting Valve Clearance‹ 3.12.2 Return to Service Recreational Vehicle Generator Part  General Hazards   Fire Hazards  Equipment Description Purpose and Scope ManualStandards Booklets Major Features and Dimensions Drawing No D8716-J ‹ 2.1.1 Generator Location Location and Support‹ 2.1.2 Generator Support Generator Compartments ‹ 2.1.4 Generator Restraint‹ 2.2.2 Compartment Construction ‹ 2.2.1 Compartment Size‹ 2.2.4 Acoustics ‹ 2.2.3 Sound Insulating Materials‹ 2.2.5 Compartment Floor Cutouts ‹ 2.3.1 Generator AirflowCompartment Floor Cutout Drawing 0G3723-A ‹ 2.3.2 Testing the Installation Gasoline Fuel System‹ 2.4.1 Fuel Tank ‹ 2.4.2 Generator Fuel Supply LineFlexible Fuel Line Exhaust System‹ 2.5.1 Spark Arrestor ‹ 2.5.2 Exhaust System Safety Electrical Connections‹ 2.6.6 Power Supply Cord ‹ 2.6.5 Isolating Different Power Sources‹ 2.6.4 Conduit ‹ 2.7.1 Recommended Battery Battery Installation‹ 2.7.2 Battery Cables Optional Accessories ‹ 2.7.3 Battery Cable Connections‹ 2.7.4 Battery Compartment ‹ 2.8.1 Remote START/STOP PanelPost Installation Tests Testing Under LoadBefore Initial START-UP Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionElectrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No D8352-K Part NO. QTY Description Recreational Vehicle Generator Generator Drawing No D8353-L QTY Description Exploded Views and Parts Lists QTY Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004709-0 specifications

Generac Power Systems has established itself as a leader in the home backup generator market with its innovative products, and the Generac 004709-0 is no exception. Designed for homeowners seeking reliable power solutions during outages, this generator ensures peace of mind and uninterrupted operation for essential appliances and electronics.

One of the primary features of the Generac 004709-0 is its robust power output. With a powerful 7,500 running watts and a surge capacity of 9,000 watts, it can efficiently handle large loads, including central air conditioning units, refrigerators, and heat pumps. This generator operates on gasoline, providing an accessible fuel source readily available at most retail locations.

Equipped with a durable 420cc engine, the 004709-0 combines efficiency with exceptional performance. It features a low-oil shutdown system, which safeguards the engine from damage by automatically shutting off when oil levels become critically low. This feature ensures longevity and reliability, making it a dependable choice for homeowners.

The portability of the Generac 004709-0 is another notable characteristic. Weighing approximately 130 pounds, it comes with a built-in handle and sturdy wheels for easy transportation. This feature allows users to move the generator effortlessly from storage to the desired location, which is especially convenient during an emergency.

In addition to power and portability, the Generac 004709-0 boasts user-friendly controls. The control panel includes four 120V household outlets, a 12V automotive outlet, and a circuit breaker, offering flexibility for various connections. Furthermore, the generator is equipped with an easy-to-read fuel gauge and a low-fuel warning light, enhancing operational visibility.

Safety is also paramount in the design of this generator. It includes a powerful muffler that significantly reduces noise and meets stringent regulations for operation in residential areas. Additionally, the 004709-0 incorporates advanced technologies like the PowerDial which allows users to select the correct power level needed for various tasks easily.

Overall, the Generac Power Systems 004709-0 stands out due to its powerful output, user-friendly design, and safety features. Homeowners can rely on this generator to keep their homes powered during outages, ensuring comfort and security for themselves and their families. With its combination of innovation and practicality, the 004709-0 continues to exemplify Generac's commitment to quality and excellence in power solutions.