Safety Rules

Recreational Vehicle Generator

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe

operation be copied and posted near the unit’s installation site. Safety should be stressed to all operators and potential operators of this equipment.

WARNING:

The engine exhaust from this product contains chemicals known to the state

of California to cause cancer, birth defects or other reproductive harm.

WARNING:

 

This product contains or emits chemicals

 

 

known to the state of California to cause

 

cancer, birth defects or other reproductive harm.

Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely, efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.

The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive. If using a procedure, work method or operating technique the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique uti- lized does not render the generator unsafe.

DANGER

Despite the safe design of this generator, operat- ing this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capa- ble persons to operate or maintain this equip- ment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot during operation. Exercise care near running generators.

GENERAL HAZARDS

For safety reasons, the manufacturer recommends that the installation, initial start-up and main- tenance of this equipment is carried out by an Authorized Service Dealer.

The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concentra- tions, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coherently, (b) nausea,

(c)vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weak- ness, and (i) sleepiness. IF EXPERIENCING ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired.

Never sleep in the vehicle while the genset is run- ning unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installation manual. Make sure there is ample fresh air when operating the genset in a confined area.

The engine exhaust fumes contain carbon monox- ide, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. This exhaust system must be installed properly, in strict com- pliance with applicable codes and standards. Following installation, do nothing that might ren- der the system unsafe or in noncompliance with such codes and standards. The generator com- partment must be completely vapor sealed from the vehicle interior. There must be no possibility of exhaust fumes entering the vehicle interior. Never operate this equipment with a leaking or defective exhaust system.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

2

Image 4
Contents Air-cooled Recreational Vehicle Generators Authorized Service Dealer Location IntroductionPart II Installation Instructions  Warning   Electrical Hazards  Generator Identification Model Number Serial Number KW Rating Rated VoltageSafety SpecificationsGenerator Applicability Generator AC Connection SystemGenerator Control Panel Before Starting the Engine Optional Remote START/STOP PanelStarting the Generator ‹ 2.8.1 LOW OIL Pressure Switch Do not Overload GeneratorStopping the Generator Protection Systems‹ 2.8.2 High Temperature Switch Additional Information‹ 2.8.3 Field Boost ‹ 2.8.4 Overvoltage Protection‹ 2.9.4 Operation in High Grass or Brush Checking the Engine OIL Level‹ 2.9.5 Effects of Moisture and Dirt ‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Clean Spark Arrestor Clean AIR IntakeChecking the Engine Spark Plug Battery Maintenance Cleaning the Generator‹ 3.8.2 Every SIX Months OUT of Service Procedure Adjusting Valve Clearance‹ 3.11.2 Return to Service ‹ 3.11.1 Removal from ServiceRV Generator Service Interval Tightening Jam NutRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Purpose and Scope Manual Equipment DescriptionGenerator Engine Operating Speed Standards BookletsView from TOP Location and Support ‹ 2.1.1 Generator Location‹ 2.2.1 Compartment Size Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.4 Acoustics ‹ 2.2.3 Sound Insulating Materials‹ 2.2.5 Compartment Floor Cutouts Compartment Floor Cutout Drawing 0G3723-A ‹ 2.3.2 Testing the Installation Cooling and Ventilating AIRLP GAS Fuel System ‹ 2.3.1 Generator Airflow‹ 2.4.3 Vapor Withdrawal ‹ 2.4.2 Some Important Considerations‹ 2.4.5 Gaseous Carburetion Exhaust System ‹ 2.4.6 Fuel Supply Lines‹ 2.4.7 Excess Flow Valve ‹ 2.4.8 Leakage TestsElectrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.5.1 Spark Arrestor ‹ 2.6.1 Electrical Junction BOX ‹ 2.6.3 Generator AC Connections14 Transfer Switch Isolation Method Battery Installation Optional AccessoriesInitial Start Before Initial START-UP‹ 2.8.1 Remote START/STOP Panel Testing Under Load Installation Checklist Troubleshooting Guide Problem Cause CorrectionRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.