Generac Power Systems 004701-0 Additional Information, ‹ 2.8.2 High Temperature Switch

Page 11

Section 2 – Operation

Recreational Vehicle Generator

‹2.8.2 HIGH TEMPERATURE SWITCH

This switch (Figure 2.2), which has normally open (N.O.) contacts, is mounted near the oil filter. The contacts close if the temperature should exceed approximately 284º F (140º C), initiating an engine shutdown.

Figure 2.2 – Low Oil Pressure and

High Temperature Switches

High Temperature Switch

Low Oil Pressure

Switch

‹2.8.3 FIELD BOOST

The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.3). During engine cranking only, a positive DC (battery) voltage is delivered through the diode, resistor, brushes and slip rings, to the generator rotor. Application of this voltage to the rotor “flashes the field” whenever it is started. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings.

Figure 2.3 – Field Boost Circuit

‹2.8.4 OVERVOLTAGE PROTECTION

A solid-state voltage regulator (Figure 2.4) controls the generator’s AC output voltage. This regulator sup- plies an excitation current to the rotor. By regulating the rotor’s excitation current, the strength of its mag- netic field is regulated and, in turn, the voltage deliv- ered to connected electrical loads is controlled. When the AC frequency is 60 Hertz, voltage is regulated at 120 volts (voltage-to-frequency ratio is 2-to-1).

Figure 2.4 – Solid State Voltage Regulator

The voltage regulator also incorporates a “voltage surge protection circuit.” This circuit prevents trou- blesome surges in the generator AC output voltage. Voltage surge is a common cause of damage to elec- tronic equipment.

2.9ADDITIONAL INFORMATION

‹2.9.1 25-HOUR BREAK-IN PERIOD

The first 25 hours of operation is the break-in period for the generator. Properly breaking in the genera- tor is essential to minimize fuel consumption and provide maximum engine performance. During this

25-hour break-in period, follow this procedure:

Run the unit at varying electrical loads to help seat the engine piston rings properly.

Check the engine oil level frequently. Add oil if needed. It is normal for the generator engine to consume more oil than is normal until the piston rings have properly seated.

For the 75-hour operation following the break-in period, avoid light electrical loads. Load the gen- erator at 50 percent (or more) of its rated watt- age capacity. Repeated light loads during these 75 hours can cause improper seating of engine piston rings, resulting in blowby and high oil consump- tion.

After operating the unit for 25 hours, complete the tasks recommended under "25-Hour Check-up".

9

Image 11
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart II Installation Instructions  Warning   Electrical Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationGenerator AC Connection System SafetySpecifications Generator ApplicabilityGenerator Control Panel Starting the Generator Optional Remote START/STOP PanelBefore Starting the Engine Protection Systems ‹ 2.8.1 LOW OIL Pressure SwitchDo not Overload Generator Stopping the Generator‹ 2.8.4 Overvoltage Protection ‹ 2.8.2 High Temperature SwitchAdditional Information ‹ 2.8.3 Field Boost‹ 2.9.5 Effects of Moisture and Dirt Checking the Engine OIL Level‹ 2.9.4 Operation in High Grass or Brush Changing the Engine OIL AND/OR OIL Filter Maintaining the Engine AIR Cleaner‹ 3.3.1 Cleaning the Foam Precleaner Checking the Engine Spark Plug Clean AIR IntakeClean Spark Arrestor ‹ 3.8.2 Every SIX Months Cleaning the GeneratorBattery Maintenance ‹ 3.11.1 Removal from Service OUT of Service ProcedureAdjusting Valve Clearance ‹ 3.11.2 Return to ServiceTightening Jam Nut RV Generator Service IntervalRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating SpeedView from TOP ‹ 2.1.1 Generator Location Location and Support‹ 2.2.2 Compartment Construction Generator Compartments‹ 2.2.1 Compartment Size ‹ 2.2.5 Compartment Floor Cutouts ‹ 2.2.3 Sound Insulating Materials‹ 2.2.4 Acoustics Compartment Floor Cutout Drawing 0G3723-A ‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the InstallationCooling and Ventilating AIR LP GAS Fuel System‹ 2.4.5 Gaseous Carburetion ‹ 2.4.2 Some Important Considerations‹ 2.4.3 Vapor Withdrawal ‹ 2.4.8 Leakage Tests Exhaust System‹ 2.4.6 Fuel Supply Lines ‹ 2.4.7 Excess Flow Valve‹ 2.5.1 Spark Arrestor ‹ 2.5.2 Exhaust System SafetyElectrical Connections ‹ 2.6.3 Generator AC Connections ‹ 2.6.1 Electrical Junction BOX14 Transfer Switch Isolation Method Optional Accessories Battery Installation‹ 2.8.1 Remote START/STOP Panel Before Initial START-UPInitial Start Testing Under Load Installation Checklist Problem Cause Correction Troubleshooting GuideRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.