Generac Power Systems 004701-0 owner manual  Fire Hazards 

Page 21

Safety Rules

Recreational Vehicle Generator

ELECTRICAL HAZARDS

FIRE HAZARDS

The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, ter- minals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If work must be done around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

During installation onto the vehicle, properly ground (bond) the generator either by solid mount- ing to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT connect the bonding conductor to any generator part that might be removed or disassembled during routine maintenance. If the grounding conductor must be replaced, use only a flexible conductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum.

If the vehicle electrical circuits can be powered by any other source of electricity (such as a “dockside” power receptacle), there must be no possibility of connecting the different power sources to the vehi- cle circuits at the same time. The dockside (utility) power source must be positively isolated from the vehicle circuits whenever the generator is operat- ing. Failure to isolate the vehicle circuits from the dockside power supply when the generator is running may result in damage to the generator or serious injury or death to dockside (utility) power workers due to backfeed of electrical energy.

In case of accident caused by electric shock, imme- diately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting imple- ment, such as a rope or board, to free the victim from the live conductor. If the victim is uncon- scious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving com- ponents causing injury.

For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installa- tion, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regula- tions.

Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged and be familiar with its use. If ther are any questions per- taining to fire extinguishers, consult the local fire department.

EXPLOSION HAZARDS

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws gov- erning the storage and handling of gasoline.

Fuel lines must be properly installed and fastened, and free of leaks. There must be no possibility of gasoline vapors entering the vehicle interior.

It is required that an approved, flexible, noncon- ductive fuel line be installed between the generator fuel connection point and rigid fuel lines.

19

Image 21
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart II Installation Instructions  Warning   Electrical Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationSpecifications SafetyGenerator Applicability Generator AC Connection SystemGenerator Control Panel Optional Remote START/STOP Panel Before Starting the EngineStarting the Generator Do not Overload Generator ‹ 2.8.1 LOW OIL Pressure SwitchStopping the Generator Protection SystemsAdditional Information ‹ 2.8.2 High Temperature Switch‹ 2.8.3 Field Boost ‹ 2.8.4 Overvoltage ProtectionChecking the Engine OIL Level ‹ 2.9.4 Operation in High Grass or Brush‹ 2.9.5 Effects of Moisture and Dirt Maintaining the Engine AIR Cleaner ‹ 3.3.1 Cleaning the Foam PrecleanerChanging the Engine OIL AND/OR OIL Filter Clean AIR Intake Clean Spark ArrestorChecking the Engine Spark Plug Cleaning the Generator Battery Maintenance‹ 3.8.2 Every SIX Months Adjusting Valve Clearance OUT of Service Procedure‹ 3.11.2 Return to Service ‹ 3.11.1 Removal from ServiceTightening Jam Nut RV Generator Service IntervalRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Equipment Description Purpose and Scope ManualGenerator Engine Operating Speed Standards BookletsView from TOP ‹ 2.1.1 Generator Location Location and SupportGenerator Compartments ‹ 2.2.1 Compartment Size‹ 2.2.2 Compartment Construction ‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.2.5 Compartment Floor Cutouts Compartment Floor Cutout Drawing 0G3723-A Cooling and Ventilating AIR ‹ 2.3.2 Testing the InstallationLP GAS Fuel System ‹ 2.3.1 Generator Airflow‹ 2.4.2 Some Important Considerations ‹ 2.4.3 Vapor Withdrawal‹ 2.4.5 Gaseous Carburetion ‹ 2.4.6 Fuel Supply Lines Exhaust System‹ 2.4.7 Excess Flow Valve ‹ 2.4.8 Leakage Tests‹ 2.5.2 Exhaust System Safety Electrical Connections‹ 2.5.1 Spark Arrestor ‹ 2.6.3 Generator AC Connections ‹ 2.6.1 Electrical Junction BOX14 Transfer Switch Isolation Method Optional Accessories Battery InstallationBefore Initial START-UP Initial Start‹ 2.8.1 Remote START/STOP Panel Testing Under Load Installation Checklist Problem Cause Correction Troubleshooting GuideRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.