Generac Power Systems 004701-0 owner manual Electrical Connections, ‹ 2.5.1 Spark Arrestor

Page 31

Section 2 – Installation

Recreational Vehicle Generator

‹2.5.1 SPARK ARRESTOR

This spark arrestor assembly meets code and stan- dard requirements of the U.S. Forest Service. Use only mufflers and parts approved by the manufactur- er. Any person(s) installing an unapproved muffler, or an unapproved exhaust system part, or modifying an exhaust system in any way that might cause a hazard, is liable for any damage, injury or warranty expense that might be caused by such unapproved installation or modification.

Failure to provide and maintain a spark arrestor may be in violation of the law. If this generator is used on any forest covered, brush covered or grass covered unimproved land, provide a spark arrestor. The vehi- cle owner or operator must maintain this device in good condition. In the state of California, the preced- ing is required by law (Section 4442 of the California Public Resources Code). Other states may have simi- lar laws. Federal laws apply on federal lands.

When installing/replacing the tailpipe or spark arres- tor components, verify that the tailpipe has a hole to securely fasten the spark arrestor components (see Figures 2.11 and 2.12). Use only manufacturer supplied hardware. Substitution of parts may cause damage to the screen or a loose fit to the tailpipe.

Figure 2.11 - Spark Arrestor

TAILPIPE

P/N 0E0683

SPARK ARRRESTOR

SCREEN P/N 089680

RETAINING

SCREW P/N 056892

‹2.5.2 EXHAUST SYSTEM SAFETY

Maintain a clearance of at least 3 inches (76 mm) between exhaust system parts and any combus- tible material (such as wood, felt, cotton, organic fibers or other like material). If the 3-inch (76 mm) clearance cannot be maintained, locate, insulate or shield the exhaust part(s) so that the temperature of any combustible material is not raised more than 117° F (65° C) above the ambient air tempera- ture.

Extend the exhaust system at least 1 inch (25 mm) past the outer edge of the vehicle. Do not terminate the exhaust system under the vehicle.

Terminate the exhaust tailpipe such that exhaust gases will not be drawn back into the generator compartment and recirculated.

If there is any possibility of the tailpipe or muffler being damaged, protect these damage-prone areas by means of a protective device (such as a skid bar).

Install the generator exhaust system according to safe automotive practices.

Use enough exhaust system hangers to prevent any part of the system from being dislocated.

Use exhaust system parts recommended by the manufacturer. Using unapproved exhaust mufflers and exhaust system parts is the responsibility of the person(s) installing such unauthorized parts.

Do not terminate the exhaust system under any opening, window or vent that can be opened or is not permanently sealed from the vehicle interior.

Exhaust piping must be large enough to prevent excessive back pressure on the generator engine.

Never tee the generator engine exhaust pipe into the vehicle engine exhaust piping. This causes excessive back pressure on the generator engine. Also, water from one engine can damage the other engine.

Plan exhaust system installation carefully. Comply with all applicable codes, standards and regula- tions.

2.6ELECTRICAL CONNECTIONS

Figure 2.12 — Spark Arrestor Installation

Be sure to read section "Generator AC Connection System".

The following general rules apply to electrical connec- tions in a recreational vehicle:

27.4 [1.08"] I.D.

40 [1.58"]

5.5 [7/32"] DRILL BOTTOM SIDE ONLY

Qualified electricians who are familiar with appli- cable codes, standards and regulations should install electrical wiring.

The wiring should comply with codes, standards and regulations. The National Electrical Code (NFPA 70), and state and local codes apply.

Switches and circuit breakers should be of a type approved for use in recreational vehicles and must be mounted and installed to prevent damage from road shock.

29

Image 31
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart II Installation Instructions  Warning   Electrical Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationGenerator AC Connection System SafetySpecifications Generator ApplicabilityGenerator Control Panel Before Starting the Engine Optional Remote START/STOP PanelStarting the Generator Protection Systems ‹ 2.8.1 LOW OIL Pressure SwitchDo not Overload Generator Stopping the Generator‹ 2.8.4 Overvoltage Protection ‹ 2.8.2 High Temperature SwitchAdditional Information ‹ 2.8.3 Field Boost‹ 2.9.4 Operation in High Grass or Brush Checking the Engine OIL Level‹ 2.9.5 Effects of Moisture and Dirt ‹ 3.3.1 Cleaning the Foam Precleaner Maintaining the Engine AIR CleanerChanging the Engine OIL AND/OR OIL Filter Clean Spark Arrestor Clean AIR IntakeChecking the Engine Spark Plug Battery Maintenance Cleaning the Generator‹ 3.8.2 Every SIX Months ‹ 3.11.1 Removal from Service OUT of Service ProcedureAdjusting Valve Clearance ‹ 3.11.2 Return to ServiceTightening Jam Nut RV Generator Service IntervalRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating SpeedView from TOP ‹ 2.1.1 Generator Location Location and Support‹ 2.2.1 Compartment Size Generator Compartments‹ 2.2.2 Compartment Construction ‹ 2.2.4 Acoustics ‹ 2.2.3 Sound Insulating Materials‹ 2.2.5 Compartment Floor Cutouts Compartment Floor Cutout Drawing 0G3723-A ‹ 2.3.1 Generator Airflow ‹ 2.3.2 Testing the InstallationCooling and Ventilating AIR LP GAS Fuel System‹ 2.4.3 Vapor Withdrawal ‹ 2.4.2 Some Important Considerations‹ 2.4.5 Gaseous Carburetion ‹ 2.4.8 Leakage Tests Exhaust System‹ 2.4.6 Fuel Supply Lines ‹ 2.4.7 Excess Flow ValveElectrical Connections ‹ 2.5.2 Exhaust System Safety‹ 2.5.1 Spark Arrestor ‹ 2.6.3 Generator AC Connections ‹ 2.6.1 Electrical Junction BOX14 Transfer Switch Isolation Method Optional Accessories Battery InstallationInitial Start Before Initial START-UP‹ 2.8.1 Remote START/STOP Panel Testing Under Load Installation Checklist Problem Cause Correction Troubleshooting GuideRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.