Generac Power Systems 004701-0 Optional Remote START/STOP Panel, Before Starting the Engine

Page 9

Section 2 – Operation

Recreational Vehicle Generator

‹2.1.4 MAIN BREAKER

The main breaker protects the generator’s AC out- put circuit against overload and provides a method of turning OFF the generator’s 120-volt AC output to the vehicle circuits. This generator has a 30-amp breaker.

‹2.3.4 COOLING AND VENTILATING AIR

Air inlet and outlet openings in the generator com- partment must be open and unobstructed for con- tinued proper operation. Without sufficient cooling and ventilating airflow, the engine/generator quickly overheats, which causes it to shut down and may damage the generator.

2.2OPTIONAL REMOTE

START/STOP PANEL

A remote mounted Start/Stop Panel is available that allows starting and stopping the generator engine conveniently from inside the vehicle.

Order part number 0F0429 or 0F0430, a remote panel that includes a Start/Stop switch, a generator run lamp, a fuel prime switch, and an hourmeter. The hourmeter provides a continuous indication of engine/generator operating time. Use the hourmeter for checking off periodic maintenance requirements on the unit.

2.3BEFORE STARTING THE ENGINE

NOTE:

Instructions and information in this manual assume the generator has been properly installed, connected, serviced, tested and adjusted by a qualified installation technician or installation contractor.

‹2.3.1 INSTALLATION

Generator installation must have been properly com- pleted so it complies with all applicable codes, stan- dards and regulations and with the manufacturer's recommendations.

‹2.3.2 ENGINE LUBRICATION

Have the engine crankcase properly serviced with the recommended oil before starting. Refer to the "Specifications", "Checking the Engine Oil Level", and Changing the Engine Oil and/or Oil Filter" sections for oil servicing procedures and recommendations.

Any attempt to crank or start the engine before it has been properly serviced it with the recom- mended oil may result in an engine failure.

‹2.3.3 FUEL SUPPLY

The engine must have an adequate supply of proper fuel to operate. Before starting it, check that suffi- cient fuel is available.

‹2.3.5 ENGINE EXHAUST GAS

Before starting the generator engine, be sure there is no way for exhaust gases to enter the vehicle interior and endanger people or animals. Close windows, doors and other openings in the vehicle that, if open, might permit exhaust gases to enter the vehicle.

DANGER

The generator engine releases DEADLY carbon monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient con- centrations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a) inability to think coher- ently, (b) nausea, (c) vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness,

(g) headaches, (h) weakness, and (i) sleepiness.

IF EXPERIENCING ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired.

DANGER

Never sleep in the vehicle while the genset is running unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installa- tion manual. Make sure there is ample fresh air when operating the genset in a confined area.

2.4STARTING THE GENERATOR

NOTE:

Read the vehicle manufacturer’s instructions. The owner/operator should become familiar with the vehicle in which this generator is installed. Differences exist between vehicles. For example, some vehicles may use a transfer switch to isolate dockside power from the generator, while other vehicles may use an isolating receptacle. Some vehicles may be equipped with a DC converter, which allows the generator to power certain DC lighting and other DC loads.

7

Image 9
Contents Air-cooled Recreational Vehicle Generators Introduction Authorized Service Dealer LocationPart II Installation Instructions  Warning   Electrical Hazards  Model Number Serial Number KW Rating Rated Voltage Generator IdentificationSpecifications SafetyGenerator Applicability Generator AC Connection SystemGenerator Control Panel Optional Remote START/STOP Panel Before Starting the EngineStarting the Generator Do not Overload Generator ‹ 2.8.1 LOW OIL Pressure SwitchStopping the Generator Protection SystemsAdditional Information ‹ 2.8.2 High Temperature Switch‹ 2.8.3 Field Boost ‹ 2.8.4 Overvoltage ProtectionChecking the Engine OIL Level ‹ 2.9.4 Operation in High Grass or Brush‹ 2.9.5 Effects of Moisture and Dirt Maintaining the Engine AIR Cleaner ‹ 3.3.1 Cleaning the Foam PrecleanerChanging the Engine OIL AND/OR OIL Filter Clean AIR Intake Clean Spark ArrestorChecking the Engine Spark Plug Cleaning the Generator Battery Maintenance‹ 3.8.2 Every SIX Months Adjusting Valve Clearance OUT of Service Procedure‹ 3.11.2 Return to Service ‹ 3.11.1 Removal from ServiceTightening Jam Nut RV Generator Service IntervalRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Equipment Description Purpose and Scope ManualGenerator Engine Operating Speed Standards BookletsView from TOP ‹ 2.1.1 Generator Location Location and SupportGenerator Compartments ‹ 2.2.1 Compartment Size‹ 2.2.2 Compartment Construction ‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.2.5 Compartment Floor Cutouts Compartment Floor Cutout Drawing 0G3723-A Cooling and Ventilating AIR ‹ 2.3.2 Testing the InstallationLP GAS Fuel System ‹ 2.3.1 Generator Airflow‹ 2.4.2 Some Important Considerations ‹ 2.4.3 Vapor Withdrawal‹ 2.4.5 Gaseous Carburetion ‹ 2.4.6 Fuel Supply Lines Exhaust System‹ 2.4.7 Excess Flow Valve ‹ 2.4.8 Leakage Tests‹ 2.5.2 Exhaust System Safety Electrical Connections‹ 2.5.1 Spark Arrestor ‹ 2.6.3 Generator AC Connections ‹ 2.6.1 Electrical Junction BOX14 Transfer Switch Isolation Method Optional Accessories Battery InstallationBefore Initial START-UP Initial Start‹ 2.8.1 Remote START/STOP Panel Testing Under Load Installation Checklist Problem Cause Correction Troubleshooting GuideRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.