Generac Power Systems 004701-0 owner manual Location and Support, ‹ 2.1.1 Generator Location

Page 24

Section 2 – Installation

Recreational Vehicle Generator

2.1LOCATION AND SUPPORT

‹2.1.1 GENERATOR LOCATION

The most desirable location for the generator set is between the vehicle's main frame members. However, this is seldom possible. Most units must be installed on the side of the vehicle and are difficult to rein- force.

Many recreational vehicles have been factory equipped with an area for the generator set. Some vehicles may even have a generator compartment provided by the vehicle manufacturer.

Plan the generator location based on the following:

The generator set must be installed on a frame- work that is part of the recreational vehicle, as outlined in the "Generator Support" section.

The location must provide an access opening that is large enough to permit generator removal (unless the generator is to be removed from under- neath the supporting framework).

The location must provide easy access to frequent- ly serviced components, such as filters, oil drains, spark plugs and other common maintenance parts.

The location must provide sufficient room to allow minimum clearances as outlined in "Generator Compartments". If sound insulation is to be used on the compartment walls and ceiling, the mini- mum recommended applies to the space between the generator and such insulation.

The location must provide adequate cooling and ventilating airflow for the generator without a great deal of work and expense.

If mounting the generator in an enclosed compart- ment, the base of the generator must rest flat on the floor without any gaps.

When using a suspended mounting system, ensure the base of the generator is flush with the sur- rounding bodywork. If the unit is mounted higher in the structure, heated air may recirculate into the generator causing it to overheat.

The generator can be installed so that it sits on top of the horizontal support tubing if the vehicle design permits. Another method is to suspend the genera- tor below the horizontal support tubing by means of suitable, structurally sound metal framework. The following general rules apply:

Vehicle construction MUST be capable of support- ing the weight of the generator.

Whether the generator is mounted above the hori- zontal support tubing or suspended below the tub- ing, the supporting frame used must be structur- ally sound.

If the generator cannot be bolted directly to the supporting frame or support tubing, con- sider using additional tubing, angle brackets or other supports to give the supporting frame suf- ficient strength.

Figure 2.1 – Typical Horizontal Support Frame

‹2.1.4 GENERATOR RESTRAINT

Use four 5/16"-18 hardened steel bolts (Grade 5) to fasten the generator to the supporting frame or the support tubing. These bolts must pass through (a) the generator mounting base, (b) the compartment floor (if a compartment is used) and (c) the support- ing framework (Figure 2.2). All bolts must be long enough so that when tight, at least three threads are visible past the retaining lock nuts. Refer to "Generator Compartments" for the location of the generator mounting holes.

‹ 2.1.2 GENERATOR SUPPORT

Figure 2.2 – Typical Generator Restraint

The generator must be securely attached to a metal framework that has been made part of the vehicle frame structure by bolting or welding. The metal framework on which the generator will rest and which will restrain the generator set should consist of at least two horizontal beams. These beams should consist of (a) 1-1/2-inch square, 11-gauge steel tub- ing OR (b) 1-1/2-inch, 11-gauge angle iron. A typical supporting frame with horizontal support tubing, is shown in Figure 2.1.

22

Image 24
Contents Air-cooled Recreational Vehicle Generators Authorized Service Dealer Location IntroductionPart II Installation Instructions  Warning   Electrical Hazards  Generator Identification Model Number Serial Number KW Rating Rated VoltageSafety SpecificationsGenerator Applicability Generator AC Connection SystemGenerator Control Panel Optional Remote START/STOP Panel Before Starting the EngineStarting the Generator ‹ 2.8.1 LOW OIL Pressure Switch Do not Overload GeneratorStopping the Generator Protection Systems‹ 2.8.2 High Temperature Switch Additional Information‹ 2.8.3 Field Boost ‹ 2.8.4 Overvoltage ProtectionChecking the Engine OIL Level ‹ 2.9.4 Operation in High Grass or Brush‹ 2.9.5 Effects of Moisture and Dirt Maintaining the Engine AIR Cleaner ‹ 3.3.1 Cleaning the Foam PrecleanerChanging the Engine OIL AND/OR OIL Filter Clean AIR Intake Clean Spark ArrestorChecking the Engine Spark Plug Cleaning the Generator Battery Maintenance‹ 3.8.2 Every SIX Months OUT of Service Procedure Adjusting Valve Clearance‹ 3.11.2 Return to Service ‹ 3.11.1 Removal from ServiceRV Generator Service Interval Tightening Jam NutRecreational Vehicle Generator Part  General Hazards   Fire Hazards  Purpose and Scope Manual Equipment DescriptionGenerator Engine Operating Speed Standards BookletsView from TOP Location and Support ‹ 2.1.1 Generator LocationGenerator Compartments ‹ 2.2.1 Compartment Size‹ 2.2.2 Compartment Construction ‹ 2.2.3 Sound Insulating Materials ‹ 2.2.4 Acoustics‹ 2.2.5 Compartment Floor Cutouts Compartment Floor Cutout Drawing 0G3723-A ‹ 2.3.2 Testing the Installation Cooling and Ventilating AIRLP GAS Fuel System ‹ 2.3.1 Generator Airflow‹ 2.4.2 Some Important Considerations ‹ 2.4.3 Vapor Withdrawal‹ 2.4.5 Gaseous Carburetion Exhaust System ‹ 2.4.6 Fuel Supply Lines‹ 2.4.7 Excess Flow Valve ‹ 2.4.8 Leakage Tests‹ 2.5.2 Exhaust System Safety Electrical Connections‹ 2.5.1 Spark Arrestor ‹ 2.6.1 Electrical Junction BOX ‹ 2.6.3 Generator AC Connections14 Transfer Switch Isolation Method Battery Installation Optional AccessoriesBefore Initial START-UP Initial Start‹ 2.8.1 Remote START/STOP Panel Testing Under Load Installation Checklist Troubleshooting Guide Problem Cause CorrectionRecreational Vehicle Generator Electrical Data Supplied by Customer Recreational Vehicle Generator Enclosure Drawing No F4589-B QTY Description Recreational Vehicle Generator Generator Drawing No F4590-C FAN, 8 Curve BLADE, 16.5MM I.D Exploded Views and Parts Lists Regulator Voltage Exploded Views and Parts Lists GUARD, FAN Exploded Views and Parts Lists Long Block Assembly 220 RV LP Recreational Vehicle Generator Regulator Drawing No F5819 CASTING, Twin Regulator Housing Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications

004701-0 specifications

Generac Power Systems has established itself as a leading provider of backup power solutions, and one of its standout products is the Generac 004701-0. Renowned for its reliability and advanced features, this model is designed to meet the growing demand for dependable power in residential and commercial applications.

At the heart of the Generac 004701-0 is its robust engine, which offers outstanding performance and efficiency. The unit is powered by a Generac 999cc V-Twin engine, specifically crafted to deliver reliable power during outages. This powerful engine ensures a significant output of up to 22,000 watts, making it suitable for larger homes or businesses that require more energy-intensive appliances to remain operational during outages.

One of the most notable features of the 004701-0 is its innovative True Power Technology. This technology provides clean and stable power, which is essential for sensitive electronics. Unlike some generators that produce a fluctuating output, Generac's True Power Technology ensures that the voltage remains consistent, preventing damage to your appliances.

Another key characteristic of the Generac 004701-0 is its user-friendly controls. The unit comes equipped with a comprehensive LED display that provides vital information at a glance, such as runtime hours and maintenance intervals. This feature ensures users can monitor their unit effectively and keep it in optimal condition.

The generator also boasts an advanced communication system that allows for remote monitoring. With the Generac Mobile Link app, users can check real-time status updates, monitor power usage, and receive alerts directly on their smartphone or tablet. This level of connectivity adds convenience and peace of mind, as users can stay informed about their power systems from anywhere.

Built with durability in mind, the 004701-0 features a corrosion-resistant enclosure that can withstand various environmental conditions. Its weather-resistant design makes it suitable for outdoor installation, ensuring that it remains operational when most needed.

The Generac 004701-0 is also designed with user safety in mind. It incorporates several safety features, including a low-oil shutdown and high-temperature shutdown, which help protect the engine from potential risks. This commitment to safety, combined with its powerful performance and advanced technology, makes the 004701-0 an exceptional choice for anyone looking for a dependable backup power solution.

Whether you're facing a storm, a power grid failure, or simply need reliable power for everyday use, the Generac 004701-0 stands ready to deliver, ensuring that you and your loved ones stay safe and comfortable.