Generac Power Systems 04758-2, 04759-2, 04760-2 owner manual Generac Power Systems, Inc

Page 40
38 Generac® Power Systems, Inc.

Section 7 — Exploded Views and Parts Lists

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators GT-990/760 Engine – Drawing No. 0E8774-J Part 2

74 Manual background

75

 

 

122

124

125

76

 

 

 

 

 

123, 145

138

Manual background139

136135

77

120

 

125

79

124

 

78

 

119

137

133

32

134

 

80

143

 

 

 

 

 

11

 

114

81

 

 

121

 

 

 

 

 

 

118

 

 

 

97

 

 

130

8

 

 

99

 

 

 

83

 

96

 

 

95

 

84

 

 

102

 

 

103

 

 

 

86

85

 

105

99

 

 

88

 

 

 

1

 

89

 

 

90

 

101

 

89

 

 

91

92

107

 

 

108

 

 

 

 

 

 

112

116 142

115

127

8

29

126

109

110

112

113Manual backgroundManual background

111

38 Generac® Power Systems, Inc.

Image 40
Contents Models 04758-2 6 kW NG, 7 kW LP 04759-2 12 kW NG, 12 kW LP 04760-2 13 kW NG, 15 kW LPThis manual should remain with the unit Installation and Owner’s Manual‹ CONTENTS ‹ OPERATION AND MAINTENANCE‹ HOW TO OBTAIN SERVICE INTRODUCTIONIntroduction GENERAL HAZARDS Despite the safe design of this generatorParts of the generator are rotating and/or hot during operation. Exercise care near running generatorsELECTRICAL HAZARDS FIRE HAZARDSEXPLOSION HAZARDS ‹ STANDARDS INDEX1.1 UNPACKING/INSPECTION 1.2 PROTECTION SYSTEMS1.3 SYSTEM SET LED DANGERFigure 1.1 - 7 kW, Single Cylinder GH-410 Engine 1.4 THE GENERATORFigure 1.2 - 12 kW/15 kW, V-twin GT-990/760 Engine ‹ 1.5.1 GENERATOR 1.5 SPECIFICATIONS‹ 1.5.2 ENGINE 1.8 RECONFIGURING THE FUEL SYSTEM 1.6 FUEL REQUIREMENTS AND RECOMMENDATIONS1.7 FUEL CONSUMPTION DANGER1.9 LOCATION 1.8.2 12KW AND 15KW, 990CC ENGINES1.9.1 GENERATOR Figure 1.4 - Demand Regulator1.10 BATTERY INSTALLATION 1.11 THE BATTERY1.9.2 TRANSFER SWITCH 1.9.2.1 7 kW, 12 kW and 15 kW Units Figure 1.5 - Battery Cable Connections2.1 BEFORE INITIAL START-UP 2.2 CHECK TRANSFER SWITCH OPERATION2.3 ELECTRICAL CHECKS 2.4 GENERATOR TESTS UNDER LOAD 2.5 CHECKING AUTOMATIC OPERATIONFigure 2.2 - Placement of Regulator 2.6 ADJUSTING THE REGULATOR NATURAL GAS ONLYFigure 2.1 - Dual Fuel Regulators 2.7 ENGINE GOVERNOR ADJUSTMENT Figure 2.4 - V-twin Engine Governor AdjustmentFigure 2.3 - Single Cylinder Engine Governor Adjustment Figure 2.5 - V-twin Full Load Speed Adjust Screw2.8 VOLTAGE REGULATOR ADJUSTMENT 3.1 BREAK-IN PROCEDURE3.2 USING THE AUTO/OFF/MANUAL SWITCH FIGURE Figure 2.6 - Voltage Adjustment Potentiometer3.3 AUTOMATIC TRANSFER OPERATION 3.5 MANUAL TRANSFER OPERATION3.4 SEQUENCE OF AUTOMATIC OPERATION ‹ 3.5.1 TRANSFER TO GENERATOR POWER SOURCE‹ 3.5.2 TRANSFER BACK TO UTILITY POWER SOURCE ‹ 3.7.1 LOW OIL PRESSURE SWITCH‹ 3.7.2 HIGH TEMPERATURE SWITCH Figure 3.2 - Manual Transfer Switch OperationFigure 3.3 - Low Oil Pressure and High Temperature Switches 4.2 CHECKING THE ENGINE OIL LEVEL4.1 FUSE ‹ 3.7.3 OVERCRANK4.5 CHANGING THE ENGINE AIR CLEANER ‹ 4.3.2 OIL CHANGE PROCEDURE4.3 CHANGING THE ENGINE OIL 4.4 CHANGING THE OIL FILTER4.7 BATTERY MAINTENANCE Figure 4.6 - 7 kW, Engine Air Cleaner LocationFigure 4.7 - 12 kW and 15 kW Engine Air Cleaner Figure 4.8 - Setting the Spark Plug GapFigure 4.10 - Valve Clearance Adjustment 4.8 ADJUSTING VALVE CLEARANCE4.9 COOLING SYSTEM 4.12 OUT OF SERVICE PROCEDURE ‹ 4.12.2 RETURN TO SERVICE‹ 4.12.1 REMOVAL FROM SERVICE 4.10 ATTENTION AFTER SUBMERSION4.13 SERVICE SCHEDULE 5.1 TROUBLESHOOTING GUIDE PROBLEMCAUSE CORRECTIONENGINE WIRING 24 Generac Power Systems, IncSection 6 - Electrical Data CUSTOMER CONTROL PANEL BOXCONNECTION Electrical Schematic - 12 & 15 kW - Drawing No. 0D8501-B 26 Generac Power Systems, IncGenerac Power Systems, Inc 28 Generac Power Systems, Inc Section 6 - Electrical DataGenerac Power Systems, Inc 225A 30 Generac Power Systems, Inc224A Electrical Schematic - 7 kW - Drawing No. 0D9014-C Section 7 - Exploded Views and Parts Lists 32 Generac Power Systems, IncPART NO. QTY. DESCRIPTION 34 Generac Power Systems, Inc PART NO. QTY. DESCRIPTION 27, 28 36 Generac Power Systems, Inc35, 36, 40 PART NO. QTY DESCRIPTION38 Generac Power Systems, Inc DESCRIPTION 40 Generac Power Systems, Inc 14 201.8 FT 1.25 FT42 Generac Power Systems, Inc 3 FT 2.6 FT1.33 FT 44 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 46 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 48 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 50 Generac Power Systems, Inc ALL DIMENSIONS IN MILLIMETERS INCHESSection 8 - Mounting Guardian Air-cooled 7 kW, 12 Drawing No. 0D3739-BSection 9 - Notes YOUR WARRANTY RIGHTS AND OBLIGATIONS MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGEPURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY STATEMENTEMISSION CONTROL SYSTEM WARRANTY EMISSION RELATED PARTS INCLUDE THE FOLLOWINGGENERAC POWER SYSTEMS TWO YEAR LIMITED WARRANTY FOR GUARDIAN PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORSWARRANTY SCHEDULE THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING