Generac Power Systems 04758-2, 04759-2, 04760-2 owner manual Mounting, and 15 kW Generators

Page 52
50 Generac® Power Systems, Inc.

50 Generac® Power Systems, Inc.

743

[29

308

[12"]

704

[27.7"]

207 [8.14"]

TRANSFER SWITCH

AIR

490.7 [

Ø30.2mm [Ø1.19"]

914mm [ 36.0" ]

MINIMUM OPEN AREA

ALL AROUND UNIT

NTAKE

Guardian Air-cooled 7 kW, 12 Drawing No. 0D3739-B

Section 8 — Mounting

(IF SUPPLIED)

LIFTING HOLES 4-CORNERS

kW

Dimensions

716 [28

"DO NOT LIFT BY THE ROOF"

604 [23.5"]

1193 [47"]

622 [24.5"]

1232 [48.5"]

LEFT SIDE VIEW

FRONT VIEW

76.2mm

[3.00"]

PEA GRAVEL

MINUMUM

149

[5.9"]

RIGHT SIDE VIEW

1172.3 [46.2"]

3/4" NPT FUEL INLET

GAS PRESSURE OF 11-14"

WATER COLUMN REQUIRED

CABLE ACCESS HOLES. (REMOVE PLUG FOR ACCESS)

260ROUNDING LUG

[10.2"]

REAR VIEW

**ALL DIMENSIONS IN:

MILLIMETERS [INCHES]

and 15 kW Generators

Image 52
Contents Models 04758-2 6 kW NG, 7 kW LP 04759-2 12 kW NG, 12 kW LP 04760-2 13 kW NG, 15 kW LPThis manual should remain with the unit Installation and Owner’s Manual‹ CONTENTS ‹ OPERATION AND MAINTENANCE‹ HOW TO OBTAIN SERVICE INTRODUCTIONIntroduction GENERAL HAZARDS Despite the safe design of this generatorParts of the generator are rotating and/or hot during operation. Exercise care near running generatorsELECTRICAL HAZARDS FIRE HAZARDSEXPLOSION HAZARDS ‹ STANDARDS INDEX1.1 UNPACKING/INSPECTION 1.2 PROTECTION SYSTEMS1.3 SYSTEM SET LED DANGERFigure 1.1 - 7 kW, Single Cylinder GH-410 Engine 1.4 THE GENERATORFigure 1.2 - 12 kW/15 kW, V-twin GT-990/760 Engine ‹ 1.5.1 GENERATOR 1.5 SPECIFICATIONS‹ 1.5.2 ENGINE 1.8 RECONFIGURING THE FUEL SYSTEM 1.6 FUEL REQUIREMENTS AND RECOMMENDATIONS1.7 FUEL CONSUMPTION DANGER1.9 LOCATION 1.8.2 12KW AND 15KW, 990CC ENGINES1.9.1 GENERATOR Figure 1.4 - Demand Regulator1.10 BATTERY INSTALLATION 1.11 THE BATTERY1.9.2 TRANSFER SWITCH 1.9.2.1 7 kW, 12 kW and 15 kW Units Figure 1.5 - Battery Cable Connections2.1 BEFORE INITIAL START-UP 2.2 CHECK TRANSFER SWITCH OPERATION2.3 ELECTRICAL CHECKS 2.4 GENERATOR TESTS UNDER LOAD 2.5 CHECKING AUTOMATIC OPERATIONFigure 2.2 - Placement of Regulator 2.6 ADJUSTING THE REGULATOR NATURAL GAS ONLYFigure 2.1 - Dual Fuel Regulators 2.7 ENGINE GOVERNOR ADJUSTMENT Figure 2.4 - V-twin Engine Governor AdjustmentFigure 2.3 - Single Cylinder Engine Governor Adjustment Figure 2.5 - V-twin Full Load Speed Adjust Screw2.8 VOLTAGE REGULATOR ADJUSTMENT 3.1 BREAK-IN PROCEDURE3.2 USING THE AUTO/OFF/MANUAL SWITCH FIGURE Figure 2.6 - Voltage Adjustment Potentiometer3.3 AUTOMATIC TRANSFER OPERATION 3.5 MANUAL TRANSFER OPERATION3.4 SEQUENCE OF AUTOMATIC OPERATION ‹ 3.5.1 TRANSFER TO GENERATOR POWER SOURCE‹ 3.5.2 TRANSFER BACK TO UTILITY POWER SOURCE ‹ 3.7.1 LOW OIL PRESSURE SWITCH‹ 3.7.2 HIGH TEMPERATURE SWITCH Figure 3.2 - Manual Transfer Switch OperationFigure 3.3 - Low Oil Pressure and High Temperature Switches 4.2 CHECKING THE ENGINE OIL LEVEL4.1 FUSE ‹ 3.7.3 OVERCRANK4.5 CHANGING THE ENGINE AIR CLEANER ‹ 4.3.2 OIL CHANGE PROCEDURE4.3 CHANGING THE ENGINE OIL 4.4 CHANGING THE OIL FILTER4.7 BATTERY MAINTENANCE Figure 4.6 - 7 kW, Engine Air Cleaner LocationFigure 4.7 - 12 kW and 15 kW Engine Air Cleaner Figure 4.8 - Setting the Spark Plug GapFigure 4.10 - Valve Clearance Adjustment 4.8 ADJUSTING VALVE CLEARANCE4.9 COOLING SYSTEM 4.12 OUT OF SERVICE PROCEDURE ‹ 4.12.2 RETURN TO SERVICE‹ 4.12.1 REMOVAL FROM SERVICE 4.10 ATTENTION AFTER SUBMERSION4.13 SERVICE SCHEDULE 5.1 TROUBLESHOOTING GUIDE PROBLEMCAUSE CORRECTIONENGINE WIRING 24 Generac Power Systems, IncSection 6 - Electrical Data CUSTOMER CONTROL PANEL BOXCONNECTION Electrical Schematic - 12 & 15 kW - Drawing No. 0D8501-B 26 Generac Power Systems, IncGenerac Power Systems, Inc 28 Generac Power Systems, Inc Section 6 - Electrical DataGenerac Power Systems, Inc 225A 30 Generac Power Systems, Inc224A Electrical Schematic - 7 kW - Drawing No. 0D9014-C Section 7 - Exploded Views and Parts Lists 32 Generac Power Systems, IncPART NO. QTY. DESCRIPTION 34 Generac Power Systems, Inc PART NO. QTY. DESCRIPTION 27, 28 36 Generac Power Systems, Inc35, 36, 40 PART NO. QTY DESCRIPTION38 Generac Power Systems, Inc DESCRIPTION 40 Generac Power Systems, Inc 14 201.8 FT 1.25 FT42 Generac Power Systems, Inc 3 FT 2.6 FT1.33 FT 44 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 46 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 48 Generac Power Systems, Inc Section 7 - Exploded Views and Parts Lists 50 Generac Power Systems, Inc ALL DIMENSIONS IN MILLIMETERS INCHESSection 8 - Mounting Guardian Air-cooled 7 kW, 12 Drawing No. 0D3739-BSection 9 - Notes YOUR WARRANTY RIGHTS AND OBLIGATIONS MANUFACTURER’S EMISSION CONTROL SYSTEM WARRANTY COVERAGEPURCHASER’S/OWNER’S WARRANTY RESPONSIBILITIES CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY STATEMENTEMISSION CONTROL SYSTEM WARRANTY EMISSION RELATED PARTS INCLUDE THE FOLLOWINGGENERAC POWER SYSTEMS TWO YEAR LIMITED WARRANTY FOR GUARDIAN PREPACKAGED EMERGENCY AUTOMATIC STANDBY GENERATORSWARRANTY SCHEDULE THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING