Generac Power Systems 05176-0 owner manual Description

Page 39

 

 

 

 

Section 9 — Exploded Views and Parts Lists

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air-cooled 15 kW Generators

 

 

 

 

 

 

 

 

Control Panel – Drawing No. 0F5846

 

 

 

 

 

ITEM

PART NO.

QTY.

DESCRIPTION

 

 

 

 

 

 

 

 

 

1

0E7886G

1

CIRCUIT BREAKER 70A X 2P 240V (15KW)

 

 

 

 

2

0A1801

1

ASSEMBLY, BATTERY CHARGER ENGINE

 

 

 

 

3

083049

1

ASSEMBLY, POTTED REGULATOR

 

 

 

 

4

0C2174

1

RELAY, 12V 25A SPST

 

 

 

 

5

075210A

2

BLOCK 1 POSITION

 

 

 

 

6

0D3062

4

HEX STAND-OFF #6-32 x 3/8"

 

 

 

 

7

0D8615

1

ASSEMBLY, HOME STANDBY CONTROLLER

 

 

 

 

8

032300

2

HOLDER, FUSE

 

 

 

 

9

022676

1

FUSE, 15AMP X AGC15

 

 

 

 

10

0E4494

1

SWITCH, ROCKER DPDT ON-OFF-ON

 

 

 

 

11

0E7890

1

CIRCUIT BREAKER MOUNTING BRACKET

 

 

 

 

12

023484E

1

SNAP BUSHING

 

 

 

 

13

075476

4

SCREW PPHM M4-0.7 x 16mm

 

 

 

 

14

0F4793

2

SCREW PPHM M3-0.5 x 10mm

 

 

 

 

15

0E6480

6

NUT HEX LOCK M4-0.7 NYLON INSERT

 

 

 

 

16

023897

2

WASHER FLAT #10

 

 

 

 

17

0C1085

4

SCREW PPHM M3-0.5 X 8mm

 

 

 

 

18

0D8443

1

DECAL, CONTROL PANEL (NOT SHOWN)

 

 

 

 

19

054502

1

CIRCUIT BREAKER 3 X 1 ETA 46-500-P

 

 

 

 

20

0F5747

1

CONTROL, PANEL BOTTOM

 

 

 

 

21

075235

4

SCREW HHC M5-0.8 x 30mm

 

 

 

 

22

0D5240

1

SWITCH, SPST (ON)-ON N/O

 

 

 

 

23

0D9784

6

NUT HEX LOCK M3-0.5 NYLON INSERT

 

 

 

 

24

0D8502

1

NEUTRAL CONNECTOR

 

 

 

 

25

031879

6

WASHER FLAT #4

 

 

 

 

26

0F5679

1

HARNESS, CONTROL PANEL (NOT SHOWN)

 

 

 

 

27

074908

4

SCREW TAPTITE, M5-0.8 x 10 BP

 

 

 

 

28

049813

1

NUT HEX M6-1.0

 

 

 

 

29

082025

6

NUT HEX LOCK M5-0.8 NYLON INSERT

 

 

 

 

30

0C3910

1

TRANSFORMER

 

 

 

 

31

022507

2

SCREW HHC 1/4"-20 x 1/2"

 

 

 

 

32

099727

1

FUSE 5A X AGC5

 

 

 

 

33

046689

1

BLOCK TERMINAL STRIP 20A 4 X 6 X 1100V

 

 

 

 

34

063617

1

RELAY PANEL 12VDC DPDT 10A 240VAC

 

 

 

 

35

075475

2

SCREW PPHM M4-0.7 x 10mm

 

 

 

 

36

043180

2

WASHER FLAT M4

 

 

 

 

37

0D8439

1

COVER, CONTROL PANEL COMPONENT

 

 

 

 

38

092036

8

SCREW PPHMS/LW #6-32 x 1/4"

 

 

 

 

39

045770

2

SCREW HHC M5-0.8 x10mm

 

 

 

 

40

0E7866

1

COVER, CONTROL PANEL

 

 

 

 

41

0D3700

8

NUT FLANGE M6-1.0 NYLOK

 

 

 

 

42

0912970069

1

ASSEMBLY, ROOF/DOOR GROUND WIRE

 

 

 

 

43

0E2874

1

SCREW HHTR 1/4"-20 X 3/4"

 

 

 

 

44

0A1658

2

WASHER LOCK SPECIAL 1/4"

 

 

 

 

45

022473

3

WASHER FLAT 1/4"-M6

 

 

 

 

46

038750

1

SCREW HHC M6-1.0 x 30mm

 

 

 

 

47

022097

3

WASHER LOCK M6-1/4"

 

 

 

 

48

027770

2

SCREW RHM #4-40 X 5/8"

 

 

 

 

49

027771

2

NUT HEX #4-40

 

 

 

 

50

043182

2

WASHER LOCK M3

 

 

 

 

51

084464

1

LIMIT SWITCH OPERATION

 

 

 

 

52

042632

1

GROMMET 1/2 X 1/16 X 3/8

 

 

 

 

37

Image 39
Contents Installation Authorized Dealer Location IntroductionSection Troubleshooting  Warning  ‹ Standards Index  Electrical Hazards UNPACKING/INSPECTION Protection SystemsSystem SET LED Generator Automatic Transfer SwitchFuel Consumption SpecificationsReconfiguring Fuel System Fuel Requirements Recommendations‹ 2.1.1 Remote Monitoring Connections Installation‹ 2.1.2 Roof Open Alarm ‹ 2.1.3 Transfer Switch ConnectionBattery Installation Check Transfer Switch Operation Battery Before Initial START-UPElectrical Checks Generator Tests Under Load Checking Automatic Operation Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment Voltage Regulator Adjustment‹ 4.1.3 Manual Position Sequence of Automatic OperationAutomatic Transfer Operation ‹ 4.1.1 Auto Position‹ 4.4.1 Close to Normal Source Side Manual OperationVoltage Checks ‹ 4.4.2 Close to Emergency Source Side‹ 4.4.3 Return to Normal Source Side ‹ 4.8.3 Overcrank Setting the Exercise Timer‹ 4.8.1 LOW OIL Pressure Switch ‹ 4.8.2 High Temperature Switch‹ 5.3.1 Engine OIL Recommendations Changing the Engine OILChecking the Engine OIL Level ‹ 4.8.4 OverspeedChanging the Engine AIR Cleaner Changing the OIL FilterSpark Plugs Adjusting Valve Clearance Battery MaintenanceCorrosion Protection OUT of Service Procedure‹ 5.12.1 Removal from Service Cooling System‹ 5.12.2 Return to Service ‹ 7 KW 40 KW Small Standby Generator Sets Service Maintenance Interval InformationMaintenance Level Level5 Tasks Maintenance Level Problem Cause Correction Troubleshooting GuideMounting Dimensions Electrical Data Control Panel BOX Transfer Switch 1VA GTS Exploded Views and Parts Lists Part NO. QTY. Description Air-cooled 15 kW Generators Control Panel Drawing No F5846 Description Exploded Views and Parts Lists Item Part NO. QTY. Description Exploded Views and Parts Lists Part NO. QTY Description Exploded QTY Description 7KW CASTING, Twin Regulator Housing Exploded Views and Parts Lists LUG Sldlss 250-#6 AL/CU Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power Systems Standard Limited Warranty for

05176-0 specifications

Generac Power Systems 05176-0 is a powerful home standby generator designed to provide reliable backup power during outages. Known for its innovative technology and robust features, the 05176-0 model is part of Generac's Guardian Series, which is renowned for its reliability and ease of use.

One of the standout features of the Generac 05176-0 is its Generac G-Force engine, which is designed specifically for generator use. This automotive-grade engine is built to handle the rigors of prolonged operation, ensuring that homeowners have a dependable source of power. With a power output of 22 kW, it can handle the essential electrical loads of many homes, allowing users to power their lights, appliances, HVAC systems, and other necessary devices without interruption.

The 05176-0 comes equipped with a state-of-the-art transfer switch that automatically detects outages and begins the power restoration process within seconds. This automatic transfer switch eliminates the need for manual intervention, giving homeowners peace of mind that their power supply will seamlessly transition during a grid failure.

In terms of fuel efficiency, the Generac 05176-0 operates on either natural gas or liquid propane, providing flexibility for installation and operation. Its dual-fuel capability allows users to choose the fuel source that is most convenient and cost-effective for them.

Another notable feature is the generator’s Quiet-Test technology, which runs the generator at reduced RPMs for a self-test every week. This helps to ensure that the generator is operational and ready when needed while minimizing noise pollution in residential areas.

The model also boasts an intuitive LCD display that provides real-time information on the generator's status, including maintenance intervals and diagnostic information. This user-friendly interface simplifies monitoring and helps ensure that users can maintain optimal performance.

Moreover, the construction and design of the 05176-0 are intended for durability and weather resistance. With a robust enclosure made from high-quality materials, it is built to withstand harsh weather conditions, allowing homeowners to trust that their generator will perform reliably in any situation.

Overall, the Generac Power Systems 05176-0 stands out as a premium choice for homeowners seeking a reliable, efficient, and easy-to-use standby generator. Its combination of power output, advanced technology, and user-friendly features makes it an essential investment for anyone looking to ensure that they remain powered during outages.