Generac Power Systems 05176-0 owner manual Part NO. QTY Description

Page 43

Section 9 — Exploded Views and Parts Lists

Air-cooled 15 kW Generators GT-990 Engine – Drawing No. 0E8774-Q Part 2

ITEM

PART NO. QTY.

DESCRIPTION

74

0C5136A

2

KNOB, AIR CLEANER

75

0C3024

1

COVER, AIRBOX NG/LP

76

0C3040

1

PRE-CLEANER,

77

0C8127

1

ELEMENT, AIR CLEANER

78

0D8564A

1

ASSEMBLY, MIXER/AIRBOX 990

 

0D8564B

1

ASSEMBLY, MIXER/AIRBOX 760

79

0D2595

4

SCREW SHOULDER (8MM) M6-1.0 X 18

80

0D4417

4

WASHER,RUBBER 1/4" X 1/8" THICK

81

0C3025

1

SWITCH, OIL PRESS

82

0D3083

1

ASSEMBLY, OIL DRAIN HOSE

83

0C7292

1

NIPPLE, 3/4"-16 UNF

84

070185B

1

OIL FILTER

85

075281

1

SWITCH, THERMAL 284F

86

0F2094

2

SCREW, M3-0.5 X 6 SEMS

87

 

 

 

88

035461

2

BARBED STR 1/4NPT X 3/8

89

0F6301

4

CLAMP, HOSE OETIKER 16.5mm

90

0G0286

2

HOSE, 3/8" I.D. X 6" LG SAE J30R9

91

0C3026

1

COOLER, OIL

92

0C9764

4

PLASTITE,1/4-15 X 3/4

93

0C3043

2

GASKET, MANIFOLD / PORT

94

0C7694

1

MANIFOLD CYLINDER 2

95

0C7693

1

MANIFOLD CYLINDER 1

96

0C3041A

2

SLEEVE, RUBBER

97

070008

4

WASHER FLAT M8 SS

98

070006

4

WASHER LOCK M8 SSTL

99

040976

4

SCREW SHC M8-1.25 X 20 G12.9

100

0C3016A

1

PLATE, BACKING WITH OIL COOLER

101

0E4997

1

GROUND WIRE CONNECTOR

102

0C3725B

1

FLYWHEEL ASSEMBLY

103

0C3031

1

FAN, NYLON

104

0C3032

1

PLATE, FAN

105

0A5992

2

WASHER SHAKEPROOF INT M8 SS

106

051754

2

SCREW HHC M8-1.25 X 12 G8.8

107

0C3033

1

WASHER, 25mm I.D.

108

0C3034

1

NUT,HEX M24

109

0C8549A

1

SNORKEL, AIR INTAKE

ITEM

PART NO. QTY.

DESCRIPTION

110

0C3022A

1

HOUSING, BLOWER NG COOLER

111

0D1131

1

GUARD, FAN

112

045756

25

SCREW TAPTITE M6-1X10 YELLOW

 

 

 

CHROME

113

0C9763

4

NUT, GROMMET 1/4 PLUG

114

0C3036A

1

HOSE, BREATHER

115

022145

1

WASHER FLAT 5/16-M8 ZINC

116

022129

1

WASHER LOCK M8-5/16

117

0C3018

1

WRAPPER, UPPER CYLINDER 1

118

0C3019

1

WRAPPER, LOWER CYLINDER 1

119

0D1142A

1

WRAPPER, LOWER CYLINDER 2

120

0D1143

1

WRAPPER, UPPER CYLINDER 2

121

0E6043

2

SCREW TAPTITE M5-0.8 X 8 ZP

122

0F1177

1

ASSEMBLY, GROUND WIRE

123

0C3052

1

ASSY, IGNITION COIL GV-990 CYLINDER 2

124

022097

4

WASHER LOCK M6-1/4

125

092079

4

SCREW TAPTITE M6-1.0 X 25 BP

126

0E4271

1

STARTER

127

0D4529

2

SPARKPLUG

128

022129

2

WASHER LOCK M8-5/16

129

061906

2

SCREW HHC M8-1.25 X 85 G8.8

130

082774

1

KEY, WOODRFF 4 X 19D

131

0E5343

1

NUT HEX LOCK M10-1.50

132

0C8468

1

SPRING, ANTI-LASH

133

0C3048

1

ROD, GOVERNOR CONTROL

134

0D3754

1

ASSEMBLY, GOVERNOR LEVER

135

0D3742

1

SPRING, GOVERNOR

136

0C8482

1

ASSEMBLY, GOVERNOR ADJUSTER

137

0E0486

1

SCREW SHC M10-1.5 X 75 G10.9

138

0D3743

1

SPRING, GOVERNOR IDLE

139

0D3705

1

ASSEMBLY, GOVERNOR ADJUSTER

 

 

 

BRACKET

140

0C2993

1

SEAL, GOVERNOR SHAFT

142

045771

1

NUT HEX M8-1.25 G8

143

0D6147

7

SCREW HHFC M6-1.0 X 10mm

144

0E8152

1

O-RING 0.49” I.D. X 0.07” THICK

145

0E7743

1

ASSY, IGNITION COIL 270mm CYLINDER 1

41

Image 43
Contents Installation Authorized Dealer Location IntroductionSection Troubleshooting  Warning  ‹ Standards Index  Electrical Hazards Protection Systems UNPACKING/INSPECTIONSystem SET LED Generator Automatic Transfer SwitchFuel Consumption SpecificationsReconfiguring Fuel System Fuel Requirements Recommendations‹ 2.1.1 Remote Monitoring Connections Installation‹ 2.1.2 Roof Open Alarm ‹ 2.1.3 Transfer Switch ConnectionBattery Installation Before Initial START-UP Check Transfer Switch Operation BatteryElectrical Checks Generator Tests Under Load Checking Automatic Operation Adjusting the Regulator Natural GAS onlyEngine Governor Adjustment Voltage Regulator Adjustment‹ 4.1.3 Manual Position Sequence of Automatic OperationAutomatic Transfer Operation ‹ 4.1.1 Auto Position‹ 4.4.1 Close to Normal Source Side Manual Operation‹ 4.4.2 Close to Emergency Source Side Voltage Checks‹ 4.4.3 Return to Normal Source Side ‹ 4.8.3 Overcrank Setting the Exercise Timer‹ 4.8.1 LOW OIL Pressure Switch ‹ 4.8.2 High Temperature Switch‹ 5.3.1 Engine OIL Recommendations Changing the Engine OILChecking the Engine OIL Level ‹ 4.8.4 OverspeedChanging the OIL Filter Changing the Engine AIR CleanerSpark Plugs Adjusting Valve Clearance Battery MaintenanceCorrosion Protection OUT of Service Procedure‹ 5.12.1 Removal from Service Cooling System‹ 5.12.2 Return to Service ‹ 7 KW 40 KW Small Standby Generator Sets Service Maintenance Interval InformationMaintenance Level Level5 Tasks Maintenance Level Problem Cause Correction Troubleshooting GuideMounting Dimensions Electrical Data Control Panel BOX Transfer Switch 1VA GTS Exploded Views and Parts Lists Part NO. QTY. Description Air-cooled 15 kW Generators Control Panel Drawing No F5846 Description Exploded Views and Parts Lists Item Part NO. QTY. Description Exploded Views and Parts Lists Part NO. QTY Description Exploded QTY Description 7KW CASTING, Twin Regulator Housing Exploded Views and Parts Lists LUG Sldlss 250-#6 AL/CU MANUFACTURER’S Emission Control System Warranty Coverage Your Warranty Rights and ObligationsPURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power Systems Standard Limited Warranty for

05176-0 specifications

Generac Power Systems 05176-0 is a powerful home standby generator designed to provide reliable backup power during outages. Known for its innovative technology and robust features, the 05176-0 model is part of Generac's Guardian Series, which is renowned for its reliability and ease of use.

One of the standout features of the Generac 05176-0 is its Generac G-Force engine, which is designed specifically for generator use. This automotive-grade engine is built to handle the rigors of prolonged operation, ensuring that homeowners have a dependable source of power. With a power output of 22 kW, it can handle the essential electrical loads of many homes, allowing users to power their lights, appliances, HVAC systems, and other necessary devices without interruption.

The 05176-0 comes equipped with a state-of-the-art transfer switch that automatically detects outages and begins the power restoration process within seconds. This automatic transfer switch eliminates the need for manual intervention, giving homeowners peace of mind that their power supply will seamlessly transition during a grid failure.

In terms of fuel efficiency, the Generac 05176-0 operates on either natural gas or liquid propane, providing flexibility for installation and operation. Its dual-fuel capability allows users to choose the fuel source that is most convenient and cost-effective for them.

Another notable feature is the generator’s Quiet-Test technology, which runs the generator at reduced RPMs for a self-test every week. This helps to ensure that the generator is operational and ready when needed while minimizing noise pollution in residential areas.

The model also boasts an intuitive LCD display that provides real-time information on the generator's status, including maintenance intervals and diagnostic information. This user-friendly interface simplifies monitoring and helps ensure that users can maintain optimal performance.

Moreover, the construction and design of the 05176-0 are intended for durability and weather resistance. With a robust enclosure made from high-quality materials, it is built to withstand harsh weather conditions, allowing homeowners to trust that their generator will perform reliably in any situation.

Overall, the Generac Power Systems 05176-0 stands out as a premium choice for homeowners seeking a reliable, efficient, and easy-to-use standby generator. Its combination of power output, advanced technology, and user-friendly features makes it an essential investment for anyone looking to ensure that they remain powered during outages.