Generac Power Systems 05176-0 Unpacking/Inspection, Protection Systems, System SET LED

Page 6

Section 1 — General Information

Air-cooled 15 kW Generators

DANGER

Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations.

1.1UNPACKING/INSPECTION

After unpacking, carefully inspect the contents for damage.

This standby generator set has been factory sup- plied with a weather protective enclosure that is intended for outdoor installation only.

If this generator is used to power electrical load circuits normally powered by a utility power source, it is required by code to install a trans- fer switch. The transfer switch must effectively isolate the electrical system from the utility distribution system when the generator is oper- ating (NEC 700, 701 and 702). Failure to isolate an electrical system by such means will result in damage to the generator and also may result in injury or death to utility power workers due to backfeed of electrical energy.

If any loss or damage is noted at time of delivery, have the person(s) making the delivery note all damage on the freight bill or affix his or her signature under the consignor's memo of loss or damage.

If there is loss or damage after delivery, separate the damaged materials and contact the carrier for claim procedures.

“Concealed damage” is understood to mean damage to the contents of a package that is not in evidence at the time of delivery, but is discovered later.

1.2PROTECTION SYSTEMS

Unlike an automobile engine, the generator may have to run for long periods of time with no operator pres- ent to monitor engine conditions. For that reason, the engine is equipped with the following systems that protect it against potentially damaging conditions:

1.

Low Oil Pressure Sensor

3.

Overcrank

2.

High Temperature Sensor

4.

Overspeed

There are LED readouts on the control panel to notify personnel that one of these faults has occurred. There is also a “System Set” LED that is described below.

1.3SYSTEM SET LED

The “System Set” LED is lit when all of the following conditions are true:

1.The AUTO/OFF/MANUAL switch is set to the AUTO position.

2.The utility voltage being supplied to the unit is being sensed by the Control PCB. If the utility sense voltage is not connected to the unit or if it is below 168 volts AC, then the system set light will flash rapidly. This indicates that if the AUTO/ OFF/MANUAL switch is placed in the Auto posi- tion , the generator will start.

3.The “Not In Auto” dip switch is set to the OFF position on the control board.

4.No alarms are present, for example, low oil pres- sure, high temperature, etc.

4

Image 6
Contents Installation Introduction Authorized Dealer LocationSection Troubleshooting  Warning   Electrical Hazards  ‹ Standards IndexUNPACKING/INSPECTION Protection SystemsSystem SET LED Automatic Transfer Switch GeneratorFuel Requirements Recommendations SpecificationsReconfiguring Fuel System Fuel ConsumptionInstallation ‹ 2.1.1 Remote Monitoring Connections‹ 2.1.3 Transfer Switch Connection ‹ 2.1.2 Roof Open AlarmBattery Installation Check Transfer Switch Operation Battery Before Initial START-UPElectrical Checks Generator Tests Under Load Adjusting the Regulator Natural GAS only Checking Automatic OperationVoltage Regulator Adjustment Engine Governor Adjustment‹ 4.1.1 Auto Position Sequence of Automatic OperationAutomatic Transfer Operation ‹ 4.1.3 Manual PositionManual Operation ‹ 4.4.1 Close to Normal Source SideVoltage Checks ‹ 4.4.2 Close to Emergency Source Side‹ 4.4.3 Return to Normal Source Side ‹ 4.8.2 High Temperature Switch Setting the Exercise Timer‹ 4.8.1 LOW OIL Pressure Switch ‹ 4.8.3 Overcrank‹ 4.8.4 Overspeed Changing the Engine OILChecking the Engine OIL Level ‹ 5.3.1 Engine OIL RecommendationsChanging the Engine AIR Cleaner Changing the OIL FilterSpark Plugs Battery Maintenance Adjusting Valve ClearanceCooling System OUT of Service Procedure‹ 5.12.1 Removal from Service Corrosion Protection‹ 5.12.2 Return to Service Service Maintenance Interval Information ‹ 7 KW 40 KW Small Standby Generator SetsMaintenance Level Level5 Tasks Maintenance Level Troubleshooting Guide Problem Cause CorrectionMounting Dimensions Electrical Data Control Panel BOX Transfer Switch 1VA GTS Exploded Views and Parts Lists Part NO. QTY. Description Air-cooled 15 kW Generators Control Panel Drawing No F5846 Description Exploded Views and Parts Lists Item Part NO. QTY. Description Exploded Views and Parts Lists Part NO. QTY Description Exploded QTY Description 7KW CASTING, Twin Regulator Housing Exploded Views and Parts Lists LUG Sldlss 250-#6 AL/CU Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Control System Warranty Emission Related Parts Include the FollowingGenerac Power Systems Standard Limited Warranty for

05176-0 specifications

Generac Power Systems 05176-0 is a powerful home standby generator designed to provide reliable backup power during outages. Known for its innovative technology and robust features, the 05176-0 model is part of Generac's Guardian Series, which is renowned for its reliability and ease of use.

One of the standout features of the Generac 05176-0 is its Generac G-Force engine, which is designed specifically for generator use. This automotive-grade engine is built to handle the rigors of prolonged operation, ensuring that homeowners have a dependable source of power. With a power output of 22 kW, it can handle the essential electrical loads of many homes, allowing users to power their lights, appliances, HVAC systems, and other necessary devices without interruption.

The 05176-0 comes equipped with a state-of-the-art transfer switch that automatically detects outages and begins the power restoration process within seconds. This automatic transfer switch eliminates the need for manual intervention, giving homeowners peace of mind that their power supply will seamlessly transition during a grid failure.

In terms of fuel efficiency, the Generac 05176-0 operates on either natural gas or liquid propane, providing flexibility for installation and operation. Its dual-fuel capability allows users to choose the fuel source that is most convenient and cost-effective for them.

Another notable feature is the generator’s Quiet-Test technology, which runs the generator at reduced RPMs for a self-test every week. This helps to ensure that the generator is operational and ready when needed while minimizing noise pollution in residential areas.

The model also boasts an intuitive LCD display that provides real-time information on the generator's status, including maintenance intervals and diagnostic information. This user-friendly interface simplifies monitoring and helps ensure that users can maintain optimal performance.

Moreover, the construction and design of the 05176-0 are intended for durability and weather resistance. With a robust enclosure made from high-quality materials, it is built to withstand harsh weather conditions, allowing homeowners to trust that their generator will perform reliably in any situation.

Overall, the Generac Power Systems 05176-0 stands out as a premium choice for homeowners seeking a reliable, efficient, and easy-to-use standby generator. Its combination of power output, advanced technology, and user-friendly features makes it an essential investment for anyone looking to ensure that they remain powered during outages.