Marantz PMD670 manual Quick Start

Page 6

Quick Start

2. Slide the POWER switch to the right and release.

Follow the instructions on this page to Quick Start your new PMD670 Portable Solid State Recorder and begin recording.

Note: Outside of the USA a CF card is not included. See page 41 for installing a CF card and page 22 to format a CF card.

Quick Start Basic Instructions

STOP

POWER

On first power up, wait for the PMD670 to initialize.

A full display will appear momentarily.

TOTAL TRACK TIME A-B

L

 

 

 

 

 

 

 

REC REMAIN kbps

 

 

 

 

 

 

 

kHz-dB 00

40

20

12

6

2

0

over

AM

R

 

 

 

 

 

 

 

PM

 

 

 

 

 

S.SKIP

 

-dB

 

INT

 

 

 

 

 

TRACK

 

 

 

 

 

 

 

MIC

 

 

 

 

 

 

 

MARK

LINE

 

 

 

 

 

 

 

DC IN 13V

f.

CANCEL

a.

REC

POWER

d.

b.

REC PAUSE

c. e.

The display will change to Loading then to Reading.

The display will change to this display for a newly formatted CF card.

L

-dB00402012620 over

R

 

 

 

 

 

 

 

 

-dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

-dB

00

40

20

12

6

2

0 over

 

 

R

 

 

 

 

 

 

 

 

-dB

INT

MIC

a. Plug the AC adapter in.

3. Slide the REC button to the right and release. Recording begins.

b. Slide the POWER switch to turn on.

c. Slide the REC switch to start recording.

d. Push and release REC PAUSE when record-

a

REC

 

ing is not necessary.

e.

Slide the REC switch to resume recording.

f.

Push the STOP button to stop recording.

Quick Start Detailed Instructions

The PMD670 comes factory preset for recording voice using its built-in (internal) microphone. These are

The Rec indicator (a) will be lit and steady while recording.

c

The display will show the recording time (b) of the current track (c).

b

TRACKTIME

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-dB

00

 

 

40

20

12

6

2

0 over

 

R

 

 

 

 

 

 

 

 

 

 

INT

 

 

 

 

 

 

 

-dB

 

 

 

 

 

 

 

 

 

 

TRACK

 

MIC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

settings for recording a meeting, not settings for recording a vocal performance. Quick Start ignores your changing any of these presets, it even ignores installing batteries.

1. Unpack the AC adapter and the PMD670.

a. Plug AC adapter into

household power.

DC IN 13V

b.Plug the adaptor jack into the PMD670 at DC IN 13V.

4.Push and release the STOP button to stop record- ing and end the track (close the audio file).

STOP

The display will

 

 

 

 

 

 

 

 

TIME

L

 

 

 

 

show the remaining

 

REC REMAIN

 

 

 

 

 

 

R

 

 

 

 

 

 

 

-dB0040

201262

0 over

recording time at

 

 

 

 

 

 

-dB

 

 

 

MIC

 

 

 

 

 

 

 

INT

 

 

 

current settings for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the CF

example shows 4 hours 21 minutes and 02 seconds

card.

remaining

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To transfer audio files to your computer:

 

 

 

transfer the CF card, see page 37,

 

 

 

 

or

 

 

 

 

 

 

 

 

connect via I/O, see page 43.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 6 -

Image 6
Contents Model PMD670 User Guide Risk of Electric Shock Important Safety Instructions Copyright CE marking only EU version English Quick Start Table of Contents Recording setup controlsWhat the Input selections do Package contents How to connect via I/O port Right sideInstalling the carry strap Bottom Left sideMIC internal microphone Control and Connection Diagrams TopSetup controls MARK/ Edit controlsBottom Battery compartment Control FrontControl Display Audio inputs may be from Security Input settingsIntroduction Audio outputs may be fromAutomatic recording FeaturesTracks EDL marksMark feature on or off Power switchAuto Mark switch Controls and ConnectionsSelects the audio output Analog OUT switch0dB -20dB9. MIC Atten switch Channel for playbackEDL Play switch Repeat switchANC switch Level CONT. switchDisplay Switch a to onInput button Mono With INT MICMono with Line input Input devices and channels Mono with INT MIC inputStereo with Line input LR mono with Line inputAdding EDL Marks Custom playback sequences16, 17, 18. MARK/ Edit buttons Locating EDL MarksHow to erase tracks Edit modeHow to renumber tracks SkipHow to erase all EDL marks within one track BlankCard will be How to erase all EDL marksHow to format a CF card DisplayedJump buttons Controls and Connections Top19, 20. Track Track Jump reverse buttonIng the Margin Reset button Margin RESET/ I/0 MENU/STORE buttonMargin Reset button MENU/STORE buttonMenu choices are Page How to set or change the Date Form Recording Type Chart of Algorithm/File ParametersAlgor/File AlgorithmHow to set or change the Algor/File parameter defaults How to set or change the Algor/File param- eters Other menu choices Manual track incrementing Seamless PlaySilent Skip Auto Cue Single Play BeepAutomatic Power Off Battery TypeRemote Mode Broadcast Wave ID numbersMenu Default PLAY/PAUSE button Enter buttonREC Level controls Turn to adjust REC 4. REC indicatorREC switch See Display onAfter the third Default displayDisplay button Press file paCF card compartment KEY Lock switchCharge 11. Charge indicator Card eject buttonSecurity Digital IN/OUT jacks15. I/O port How to connect via the I/O port Remote jack JacksLine OUT jacks RemoteModeInstalling the carry strap Battery power Installing AA size batteriesInstalling an optional Ni-Cd or Ni-MH battery Track label REC labelTotal label Remain labelLine label BatteryMIC/INT MIC label RecordMp3 Troubleshooting Specifications Limited Warranty Marantz is a registered trademark 2003/6