Casablanca Fan Company PN9943001 warranty Safety First

Page 1

CONTENTS

 

INTRODUCTION

1

MOUNTING RECOMMENDATIONS

2

FAN INSTALLATION

3

CONTROL FEATURES:

 

INTELI•TOUCH OPERATION

12

WALL CONTROL PREPARATION

11

OPERATION

15

CHANGING TRANSMITTER FREQUENCY SETTING

16

BEZEL REPLACEMENT

19

READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this owner’s manual completely and carefully. Retain this manual for future reference.

CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at the circuit breaker or fuse box before attempting any installation procedure.

BEFOREYOU START

All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualified electrician should be consulted if you are unsure.

This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan installations, if it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling installations.

This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light current is 2.8 amps or 340 watts of lighting.

Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make sure all wires are within the canopy and that no wires are being pinched.

For best performance and for your warranty to be valid,

use only genuine Casablanca blades, light fixtures, and accessories.

SAFE USE

The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.

Inspect the contents of your carton for possible shipping or handling damage and report any such damage directly to your authorized Casablanca dealer.

It is always a good idea to have an assistant to help with the installation.

When cleaning, painting, or working near your fan, be very careful of the fan and blades. Always turn the power OFF to the ceiling fan before servicing it, working on it, or replacing light bulbs.

Never insert anything into the path of the fan blades while the fan is in operation.

Never install a fan over a pool or spa.

Never operate a fan that has been damaged in any way. Contact Casablanca Fan Company by calling 1-888-227-2178, or contact your local authorized Casablanca dealer for assistance in obtaining service.

FUSE BOX

(REMOVE FUSE FOR THE CIRCUIT YOU WILL BE WORKING ON)

CIRCUIT BREAKER

(TRIP BREAKER FOR THE

CIRCUIT YOU WILL BE

WORKING ON)

18

70

84

1

PN 9943001 RL1210

1

 

 

 

 

 

Image 1
Contents Safety First Mounting Recommendations Sloped Ceiling InstallationsInstall Metal Gasket Install Rubber GasketPreparation Instructions Getting StartedInstalling a New Ceiling Fixture Outlet Box Prepare for fan installation as followsUsing Existing Ceiling Fixture Outlet Box FAN PreparationCrossbar Mounting Bracket Installation Support Installation PartsCeiling Hardware LAG Screww Insatallation Canopy InstallationCanopy Hardware Hangingthe FAN Canopy Hatch InstallationCanopy Electrical Connections Install Motor Cover Install Canopy CoverDisassemble Canopy and Motor Covers Blade Hardware Install Blade AssemblyAttach Blade Holders Switch Housing CUP Installation Wall Control Preparation Prepare for W-84 Wall Control Bezel replacement as followsAlmond Bezel Prepare for W-84 Wall Control installationSingle W-84 Installation Control Installation Installing the W-84 Wall ControlDual W-84 Installation To dim both lights at the same time Operation PowerLight button To dim just the up light Changing Frequency SettingTo dim just the down light Operation SAFE-EXITAND LIGHT-MINDERPROGRAM Automatic Demonstration ProgramTo enter the demonstration program To enter the Light-Minder ProgramOperation FAN-MINDERPROGRAM Operation HOME-SAFEPROGRAMScrews Wall Bezel ReplacementLocating Pins HOLES4 Rubber KEY PAD Wall Control Bezel replacementFigure #7 Troubleshootingtips Care Recommendations Product Specifications