INSTALL THE BLOWER

INSTALL THE BLOWER

 

INSTALL THE BLOWER

ROOF INSTALLATIONS

WALL INSTALLATIONS

1.Remove the cover and screws.

2.Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.

3.Remove roofing nails from shingles around the TOP and SIDES of the cut- out area only.Carefully lift the shingles to allow the back flashing sheet on the blower housing to fit under them.

4.Center the blower ring in the 11" diam- eter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.

5.Attach the blower to the roof with six (6) screws provided. It is recommended that the screws be located inside the blower housing. Drill pilot holes if neces- sary.

6.Using a good grade of roofing cement, seal all of the shingles around the hous- ing and flashing sheet as well as the mounting screw heads.

7.Bring electrical wiring through the hole in the wiring box and secure it according to local codes.

GROUND

TO

GROUNDING

SCREW

WHITE

TO

BROWN

120 VAC

LINE

IN

BLACK

TO

BLUE

8.Make the electrical connections with the proper connector for the type of wiring being used. Connect black to blue, white to brown, and the green or bare wire to grounding screw.

9.Replace cover and screws. Do not pinch wiring under the cover.

10.Make sure damper opens and closes freely.

1.Place a large bead of caulk on the back side of the housing all along the outer edges.

2.Center the blower ring in the 11" diam- eter hole, making sure that the 1¼" diameter electrical wiring hole aligns with the hole in the wiring box.

3.Attach blower to the wall with the six (6) screws provided. It is recommended that the screws be located inside the blower housing. Drill pilot holes if neces- sary.

4.Using a good grade of caulk, seal all around the mounting screw heads.

5.Bring electrical wiring through the hole in the wiring box and secure it according to local codes.

GROUND

TO

GROUNDING

SCREW

WHITE

TO

BROWN

120 VAC

LINE

IN

BLACK

TO

BLUE

6.Make the electrical connections with the proper connector for the type of wire being used. Connect black to blue, white to brown, and green or bare wire to grounding screw.

7.Replace cover and screws. Do not pinch wiring under cover.

8.Make sure damper opens and closes freely.

9.Top and side flanges of the back plate may be covered with trim strips. Do not block grille opening at bottom with trim. It will adversely affect performance of the blower.

4

Image 4
Contents Model EB15 EXTERIOR MOUNTED BLOWERFOR USE WITH BEST BY BROAN K210A OR K260A SERIES RANGE HOODS BEST BY BROAN, P.O. BOX 140 HARTFORD, WISPECIFICATIONS PLAN THE INSTALLATIONALL INSTALLATIONS INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use And CareINSTALLATION LOCATION ROOF INSTALLATIONSWALL INSTALLATIONS PREPARE THEINSTALL THE BLOWER 1. Remove the cover and screwsWARRANTY BROAN ONE YEAR LIMITED WARRANTYUSE AND CARE SERVICE PARTSMODEL EB15 Modelo EB15 VENTILADOR DE MONTAJE EXTERIORPARA USARSE CON LAS COMPANAS “BEST BY BROAN” DE ESTUFA SERIES K210A O K260ALEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIAADVERTENCIAESPECIFICACIONES PRECAUCIONPREPARE EL ÁREA DE LA PREPARE ÁREA DE LAINSTALACION INSTALACIONES DE TECHOINSTALE DEL VENTILADOR 1. Quite la cubierta y los tornillosGARANTIA GARANTÍA BROAN LIMITADA POR UN AÑOUSO Y CUIDADO PARTES DE SERVICIOLIMPIEZA LUBRICACION DELVENTILATEUR À MONTAGE EXTÉRIEUR Modèle EB15À UTILISER AVEC LES HOTTES “BEST BY BROAN” DE SÉRIE K210A OU K260A PLANNIFICATION DE L’INSTALLATION TOUTES LES INSTALLATIONSINSTALLATEUR Donner ce manuel au propriétaire INSTALLATION UN MUR TYPE SUR UN TOITINSTALLATIONS SUR UN TOIT PRÉPARATION DE L’INSTALLATIONINSTALLATIONS SUR UN MUR INSTALLATIONS SUR LE TOIT INSTALLATIONS SUR LE MURINSTALLATIONDUVENTILATEUR INSTALLATIONDUVENTILATEURGARANTIE LIMITÉE D´UN AN DE BROAN USAGE ET ENTRETIEN PIÈCES DE RECHANGENETTOYAGE LUBRIFICATION DU MOTEURPage 99042940C