Broan manual Use And Care, Service Parts, MODEL EB15

Page 6
USE AND CARE

USE AND CARE

Disconnect electrical power sup- ply and lock out service panel be- fore cleaning or servicing this unit.

CLEANING

Remove cover and carefully vacuum blower and inside of hous- ing. Be careful not to bend or oth- erwise damage blower wheel.

MOTOR LUBRICATION

The motor is permanently lubri- cated. Do not oil or disassemble motor.

4

13

6

SERVICE PARTS

MODEL EB15

1

3 SERVICE PARTS

7

5

 

2

14

13

 

15

16

 

 

17

18

18

10

11

9

8 MODEL EB1512

19

Manual backgroundManual background15

20

KEY

PART

 

NO.

NO.

DESCRIPTION

1

98009538

Cover

2

99100531

Foam Seal

3

98009539

Motor Support

4

98009541

Damper Flap (2 req.)

5

99140145

Damper Spring (2 req.)

6

98009537

Grille

7

99080479

Blower Assembly

8

99271203

Capacitor

9

99271221

Wire Assembly

10

99100530

Terminal Boot

11

99390136

Capacitor Clamp

12

99400079

Bushing

13

99150478

Screw, 8-18 x 3/8 Ph Tr Hd (12 req.)

14

99170269

Screw, M6 x 1.0-16 (4 req.)

15

99250958

Washer, Lock, Int. Tooth, ¼ (5 req.)

16

99150506

Screw, 12-24 x .312 SLT HWH #2

17

99270461

Cord Clamp

18

99260477

Nut, Whiz, ¼-20 (9 req.)

19

99150471

Ground Screw, 10-32 x ½ Slt Hx Hd

 

 

(2 req.)

20

99160411

Screw, ¼-20 x ½ Ph Pan Hd (9 req.)

 

 

 

*Standard Hardware - may be purchased locally.

Order replace- ment parts by Part No. - NOT by Key No.

6

Image 6
Contents FOR USE WITH BEST BY BROAN K210A OR K260A SERIES RANGE HOODS Model EB15EXTERIOR MOUNTED BLOWER BEST BY BROAN, P.O. BOX 140 HARTFORD, WIALL INSTALLATIONS SPECIFICATIONSPLAN THE INSTALLATION INSTALLER Leave This Manual With The Homeowner HOMEOWNER Use And CareWALL INSTALLATIONS INSTALLATION LOCATIONROOF INSTALLATIONS PREPARE THEINSTALL THE BLOWER 1. Remove the cover and screwsWARRANTY BROAN ONE YEAR LIMITED WARRANTYSERVICE PARTS USE AND CAREMODEL EB15 PARA USARSE CON LAS COMPANAS “BEST BY BROAN” DE ESTUFA Modelo EB15VENTILADOR DE MONTAJE EXTERIOR SERIES K210A O K260AESPECIFICACIONES LEA Y CONSERVE ESTAS INSTRUCCIONESADVERTENCIAADVERTENCIA PRECAUCIONINSTALACION PREPARE EL ÁREA DE LAPREPARE ÁREA DE LA INSTALACIONES DE TECHOINSTALE DEL VENTILADOR 1. Quite la cubierta y los tornillosGARANTIA GARANTÍA BROAN LIMITADA POR UN AÑOLIMPIEZA USO Y CUIDADOPARTES DE SERVICIO LUBRICACION DELModèle EB15 VENTILATEUR À MONTAGE EXTÉRIEURÀ UTILISER AVEC LES HOTTES “BEST BY BROAN” DE SÉRIE K210A OU K260A INSTALLATEUR Donner ce manuel au propriétaire PLANNIFICATION DE L’INSTALLATIONTOUTES LES INSTALLATIONS INSTALLATION UN MUR TYPE SUR UN TOITPRÉPARATION DE L’INSTALLATION INSTALLATIONS SUR UN TOITINSTALLATIONS SUR UN MUR INSTALLATIONDUVENTILATEUR INSTALLATIONS SUR LE TOITINSTALLATIONS SUR LE MUR INSTALLATIONDUVENTILATEURGARANTIE LIMITÉE D´UN AN DE BROAN NETTOYAGE USAGE ET ENTRETIENPIÈCES DE RECHANGE LUBRIFICATION DU MOTEURPage 99042940C