INSTALLATION INSTRUCTIONS
electrical installation:
WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRICIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
WARNING: When using electrical products, precautions should always be followed, including the following:
DANGER: RISK OF ELECTRIC SHOCK!
GFCIs are not supplied, however we do specify their use.
All known code authorities require GFCIs.
LuxeAir baths will need to be
Two junction boxes will be mounted to the frame of the whirlpool. One of the two boxes will have one outlet and will be labeled “Blower”. Remove the cover and connect a 14/2 with ground Romex wire from a 15 amp
The second junction box will have two outlets, one labeled “Main” and the other labeled “Heater”. Remove the cover. Run Romex 14/3 with ground from a 15 amp
CAUTION: Before use of the pump and heater, test the GFCI for proper operation. The pump and heater should turn off when the GFCI “Test” button is pushed.
Aquatic Industries, Inc. | 11 |