operation of
LuxeAir with Optional Chromatherapy
BATHside CONTROL SYSTEMS (continued):
Purge 24 Hours:
It is possible for the user to program a purge cycle that will start every day for a duration of 1 minute. Aquatic strongly recommends activating this feature. The purge cycle will help ensure that the air channels stay dry even when you have taken a soaking bath or shower.
To activate this purge feature, the user must hold down the “+” button for 5 seconds when the blower/heater is off or waiting for the normal purge. Then, the light indicator on the on/off button will blink twice. If the unit was in standby for a normal purge when the 24 hour purge was activated, the normal purge will be cancelled.
To show the user that the 24 hour purge is activated, the light indicator on the on/off button will blink at a slow rate. A different blinking rate was picked in order to make it easier for the user to differentiate it from the standby of the regular purge cycle.
The purge will be done every day at the same time the user activated it (pressed the “+” button). By pressing the “+” button again, the 24 hour purge will be deactivated and the light indicator on the on/off button will stop blinking and turn off.
On/Off CONTROL for Jets (Pump):
NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2” ABOVE HIGHEST JET.
The On/Off Electronic Button with Timer is the On/Off Button for the pump/jet action for the LuxeAir baths with optional chromatherapy.
1.Make sure whirlpool has enough water in it to submerge the highest jets by about 2 inches of water.
2.Push the On/Off Button once to turn the pump on. The whirlpool has a
3.When the motor is running, push the On/Off Button to turn the pump off.
20 | Aquatic Industries, Inc. |