Aquatic LuxeAir Series LuxeAir series Control Panel, BATHside Control Systems, Purge 24 Hours

Page 18

LuxeAir series Control Panel

BATHside CONTROL SYSTEMS:

To Turn Blower (Air System) On: Press once to turn the blower (air system) on. A second press will turn the blower off. Holding the button down for 2 seconds will change modes when the blower is on. There is a 20 minute timer that will automatically turn the blower off.

Press once to turn the pump (jets) on. A second press will turn

the pump off. There is a 20 minute timer that will automatically turn the pump off.

To Change Modes: Holding this button down for 2 seconds will change modes when the blower is on. There is a 20 minute timer that will automatically turn the blower off.

Constant Mode: Consists of a constant blower speed.

Wave Mode: Consists of a gradual change of blower speed to generate a gentle massage effect.

Pulse Mode: Consists of an instant change of the blower speed to generate a massage effect.

To Change Speeds: Pressing this button will increase the blower speed. Holding down this button will continue to increase the blower speed until the maximum speed is obtained.

Pressing this button will decrease the blower speed. Holding down this button will continue to decrease the blower speed until the minimum speed is obtained. The blower’s heater will only be fully on at maximum speed. As you decrease the speed of the blower, the heater’s output will decrease.

CAUTION: Due to varied size, weight and shape of a person’s body, water may splash out of the tub when the

air blower is on high speed. Turn the speed of the blower down using the minus button to a lower setting to reduce the amount of water being dispersed from the tub.

Air Bath Purge Cycle:

Twenty minutes after the pump or blower is turned off, either manually or by the timer, the blower will turn on at full power for 3 minutes to purge the air channels of water. During this 20 minute waiting period, depressing the on/off button will cancel the purge cycle and starts another massage cycle.

During the 3 minute purge cycle, depressing the on/off button will cancel the remaining purge cycle.

Automated dry Cycle:

Regardless if the air bath system was utilized, an automated dry cycle will turn on 20 minutes after the water sensors do not detect water. The automated dry cycle will turn on for 3 minutes (once the sensors are dry) to purge the air channels after any contact with water, including after a shower or cleaning/rinsing of the bath. The two water sensors are located near the drain.

Purge 24 Hours:

24 hour purge: The blower automatically comes on to purge the air channels of water. This will happen every 24 hours from the time the 24 hour purge was activated.

Activating the 24 hour purge: Holding down the on/off pump button for 5 seconds when the blower is off will activate the 24 hour purge cycle. The blower will then come on to purge the air channels every 24 hours from the time it was set.

This will be confirmed by the blower coming on for 1 second, turning off for 2 seconds and then coming back on for 1 second.

Cancelling the 24 hour purge cycle (not recommended): Holding down the on/off pump button for 5 seconds when the blower is off will cancel the 24 hour purge cycle.

This will be confirmed by the blower coming on for 1 second and then turning off.

18

Aquatic Industries, Inc.

Image 18
Contents Iesluxeair SER Table of Contents Aquatic Industries, Inc Owner InformationAquatic Industries Customer Service Center CongratulationsRead and Follow ALL Instructions Installation Instruction Guidelines Installation Instructions IMPORTANT! Before installation begins, make sure that Factory installed tile flangeAlcove Framing and pre -Installation Procedures Structural PreparationInstallation Procedures for integrally skirted modelS Removable Skirt Panels for Integrally Skirted ModelSPlumbing Rough-In MeasurementsElectrical installation Heater Main Luxeair Block Diagram With Chromatherapy Option Full Size Pressure-Flo Hydrotherapy Jet Operation of LuxeAir seriesLuxEAIR Series Whirlpool Jets Aquatic Rotary Massage JetStress-Eaz Neck and Shoulder Jets some models 11A 11B11C Inline maintenance heater operating instructions Full Size Pressure-Flo Hydrotherapy Jets12B 12C Air Bath Purge Cycle LuxeAir series Control PanelBATHside Control Systems Automated dry CycleElectronic Control Panel see Diagram 11A Operation LuxeAir with Optional Chromatherapy11A On/Off Control for Jets Pump Optional Chromatherapy LED lighting To Replace BulbMaintenance and care Whirlpool system cleaningAir bath system cleaning Water quality issues Chemical QualityTreatment Fcc consumer information Electrical Installation Information Listed onWhirlpool user information Serial Number LocationJet Cleaning RepairMicrobiological Quality Troubleshooting guide Symptoms Possible problems Suggested solutionsQuantity Description Replacement parts Order formFor LuxEAir series How To Use PriceLuxeair Series Replacement Parts Order Map 11a Assorted Fittings10 a b 12a13a LuxeAir Bath Parts List 93ORBDWO Aquatic Industries, Inc. Limited Lifetime Warranty Page LAOM6 11/08