Cal Spas GFCI Filling and Powering Up Your Portable Spa, Never fill your spa with soft water

Page 12

Preparing for Your New Portable Spa

Filling and Powering Up Your Portable Spa

Never fill your spa with soft water.

Soft water makes it impossible to maintain the proper water chemistry and may cause the water to foam, which will ultimately harm the finish of the spa and void your warranty.

1.Once the spa has been placed on an approved surface and has been correctly wired by a licensed electrician, inspect all plumbing connections in the equipment area of your spa. Ensure that these connections are secure and that they did not loosen during shipment.

2.If equipped, open all gate valves in the equipment area. Before operating the spa, these valves must be in the up or “open” position.

VERY IMPORTANT!

Never run the spa with the gate valves closed or without water circulating for long periods of time. Be careful not to over-tighten the plumbing fittings.

3.Remove the filter basket and cartridge from filter canister.

4.Place a garden hose in the skimmer/filter canister and fill your spa with regular tap water to the proper water level (halfway up the skimmer area).

VERY IMPORTANT!

Always fill the spa through the filter canister! Failure to do so may cause air to be trapped in the filtration system and prevent the pumps from operating properly.

5.Presoak the filters in spa water.

VERY IMPORTANT!

You must presoak the filters before inserting them in the filter canister. Dry filters can allow air into the filtration system which can cause pump failure.

6.(For owners of the automatic bromine generator) Make sure the dial on the face of the bromine generator unit is turned to the OFF position.

7.Once the water is at the correct level and air is bled, turn on the power at the GFCI breaker. (Ensure that the 120V spas are connected to the proper electrical outlet.)

Note: Depending on the model, when the power is turned on to the spa, the controls will perform a diagnostic check for approximately five minutes.

When the diagnostic is complete, the spa will automatically operate at filter speed and continue heating until the spa water temperature reaches the default temperature of 100˚F.

8.If no water is flowing when the pump is running, there could be an air pocket at the suction side of the pump. Shut off power to the spa and loosen the pump union on the suction side of the pump to bleed the air. When air is bled, turn power back on.

9.Install the pre-soaked filters and the filter basket into the filter canister.

The spa is now ready for use.

Page 10

2008 Portable Spa Owner’s Manual

LTR20081000, Rev. D

Image 12
Contents LTR20081000, Rev. D 12/08 Cleaning and Maintenance Using the Entertainment SystemWater Quality Maintenance Appendix Read This FirstImportant Safety Instructions Read This FirstBasic Spa Information Hyperthermia DangerRead This First Preparing for Your New Portable Spa Planning the Best LocationPreparing a Good Foundation Volt Electrical Installation Gfci and Wiring RequirementsTesting the Gfci Breaker Spa Model Gfci Required Wires Required See Configuration InstructionsConfiguring the 6300 Control System Electrical Installation for 11 kW HeaterGfci Wiring Diagram Gas Heater Hook up Preparing for Your New Portable Spa Filling and Powering Up Your Portable Spa Never fill your spa with soft waterOperating Your Spa 5100, 6200 and 6300 Electronic Control OperationSetting Filtration Cycles Diagnostic Messages MeaningLight OptionOperating Your Spa Electronic Control Operation Initial Start-upTime Standard, Economy, Sleep, and StandbyPreset Filter Cycles Setting the Temperature LockClean up Cycle InvertDiagnostic Messages Meaning Action Required Periodic Reminder MessagesMessage Frequency Action Required Message Meaning Action Required DryOr --C StbyWireless Spa Monitor Auxiliary Panel Configuration FunctionsAuxiliary Control Operation Adjustable Jets Diverter Knobs Air VenturisAdjustable Therapy System Multi-Colored Spa Light OperationAromatherapy WaterfallsWater Quality Maintenance Cal Spas Clear Water PlanAlternative Sanitation Options Before You BeginChemical Safety Bather LoadChemical Overview Physical Chemical HazardsChemical Descriptions For use with any Clear Water PlanFor use with the chlorine Clear Water Plan For use with the bromine Clear Water PlanFor use with the Cal Clarity Bromine Generator Traditional Chemical Start Up Bromine Clear Water Plan Start UpDay One Monday Day Two WednesdayChlorine Clear Water Plan Ozonator Clear Water PlanDay One Monday Day Two WednesdayBromine Generator Clear Water Plan Day Two FridayMaintenance Schedule Cleaning and Maintenance Removing and Reseating the PillowsSpa Cover Freeze damage is not covered by your warranty Draining Your Portable SpaWinterizing Cold Climate Draining Cleaning the Cover, Shell and Pillows Cleaning and Replacing the Filter Exclusive Bio-Clean Filter CartridgeUsing the Entertainment System Listening to the RadioInserting and Ejecting a CD or Functions for Aeware DVD playerPlaying a CD Raising and LoweringPlaying a Movie This applies to the Aeware system onlyUsing the Universal Remote Control Programming the Universal Remote Control Using the iPod Docking StationDevice Manufacturer Device Type Code Replacement Parts AppendixMNW SXW Neck JET, Quad Blaster Power Storm JET, Swirley Valves PillowsDrains WaterfallsReplacement Cabinet Panels FiltersPumps LED LightsCovers Avalon SeriesClassic / Legacy Series DIJ-404 93 x Fitness Series Family SeriesAppendix Keeping Fit with your Spa Ultimate Fitness Series Exercise ProgramConnecting the Exercise Equipment Cal Spas Chemicals Warranty Warranty Specifics Warranty LimitationsWarranty Exclusions Locating the product serial number

GFCI specifications

Cal Spas GFCI (Ground Fault Circuit Interrupter) is an essential safety feature incorporated in Cal Spas hot tubs and spas, designed to protect users from electrical shocks and enhance overall safety during relaxation. This advanced technology monitors the electrical current flowing through the spa's components, providing peace of mind for families and individuals enjoying their hydrotherapy experience.

One of the main features of the Cal Spas GFCI is its quick response time. The GFCI continuously measures the current balance between the hot and neutral wires. If it detects an imbalance, potentially caused by faulty wiring or a short circuit, it immediately trips the circuit, cutting off power to the unit within a fraction of a second. This rapid response significantly minimizes the risk of electrical accidents, making it a vital component for any outdoor or indoor spa setup.

Another key characteristic of the Cal Spas GFCI is its user-friendly design. The GFCI outlet is often equipped with a reset button, which allows users to quickly restore power once the issue has been addressed. This feature eliminates the need for complicated maintenance procedures, ensuring that users can enjoy their spa without frequent interruptions.

Incorporating state-of-the-art technology, Cal Spas GFCI is designed to withstand the rigors of outdoor environments. The durable exterior of the GFCI unit protects it from exposure to moisture, debris, and other potential hazards, leading to increased longevity and reliability. Moreover, the GFCI meets the highest safety standards and regulations, providing confidence to consumers that they are investing in a safe product.

Another highlight of the Cal Spas GFCI is its compatibility with a variety of hot tub configurations. This flexibility allows it to work seamlessly with different Cal Spas models, delivering consistent safety features across the entire range. Additionally, installation is straightforward, with many users opting for professional installation to ensure it is set up correctly.

In summary, Cal Spas GFCI enhances the safety of hot tub and spa experiences through its quick trip response, durable design, user-friendly functionalities, and compatibility with various models. By integrating this technology, Cal Spas demonstrates its commitment to providing a safe and enjoyable environment for relaxation and rejuvenation.