Cal Spas GFCI manual Preset Filter Cycles, Invert, Locking the Panel, Setting the Temperature Lock

Page 17

Jets 2

Press the “JETS 2” button once to turn pump 2 on or off and to shift between low and high speeds if it is a two- speed pump. If left running, the pump will turn off after 15 minutes.

Operating Your Spa

Preset Filter Cycles

There are two filter cycles per day. The start and end times of each cycle are programmable. To program, set the time as instructed above, then press “MODE/PROG” to advance to the next setting (or to exit after the last setting). The default filter cycles are as follows:

Option

This is an optional feature. Press the “OPTION” button to turn the optional equipment on and off. If left on, the equipment will automatically turn off after 15 minutes.

Light

Press the “LIGHT” button to turn the spa light on and off and to shift between dim and bright settings if your light is dimmable. On dim, the control panel will show the center circle plus one quarter of the light beams. Half of the light beams will show on medium brightness, and all of the light beams will show on bright.

Invert

Press the “INVERT” button to change the numbers in the display to read upside down. Another press returns the display to the right-side-up position. This enables you to read the display while you are in the spa.

Locking the Panel

To lock the panel:

Press “TIME”, “JETS 1”, and the “UP” button within three seconds. When locked, the panel will display “LOCK”. All buttons are frozen except the “TIME” button.

To unlock the panel:

Press “TIME”, “JETS 1” then the “DOWN” button within three seconds.

Setting the Temperature Lock

To activate the temperature lock:

Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, then the “UP” button within three seconds. The panel will display “TEMP LOCK” when the set temperature is locked.

To unlock the set temperature:

Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, and then the “DOWN” button.

Circulation Pump

This is an optional feature. The circulation pump will come on when the system is checking temperature,

during filter cycles, during freeze conditions, or when

another pump is on.

The first filter cycle is automatically activated at 8:00

AM and operates the pump until 10:00 AM. The

“FILTER 1” indicator icon will light when filter 1 is running.

The second filter cycle is automatically activated at

8:00 PM and operates the pump until 10:00 PM. The

“FILTER 2” indicator icon will light when filter 2 is running.

The pump and the ozone generator will run during filtration. At the start of each filter cycle, the blower will run on highest speed for 30 seconds to clean out the air channels. The lowest speed of pump 2 and pump 3 will run for five minutes. In the event of power loss or shut down, the time of day will need to be reset for filter cycles to run according to your desired programming.

Clean up Cycle

When the pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for one hour.

Ozone

This is an optional feature. On most systems, the ozone

generator (if installed) runs during filter cycles (except

when pump 1 is operating at high speed on a non-circ ulating system) and during clean-up cycles. On some systems, the ozone generator operates whenever the

pump runs. If your system is configured with the optional

ozone disable feature, the ozone generator will turn off for one hour any time a function button (“JETS 1”, “JETS 2”, “OPTION” etc.) is pressed.

Freeze Protection

If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a four-minute delay in turnoff.

2008 Portable Spa Owner’s Manual

Page 15

LTR20081000, Rev. D

Image 17
Contents LTR20081000, Rev. D 12/08 Using the Entertainment System Cleaning and MaintenanceWater Quality Maintenance Appendix Read This FirstRead This First Important Safety InstructionsBasic Spa Information Hyperthermia DangerRead This First Preparing a Good Foundation Preparing for Your New Portable SpaPlanning the Best Location Testing the Gfci Breaker Volt Electrical InstallationGfci and Wiring Requirements See Configuration Instructions Spa Model Gfci Required Wires RequiredElectrical Installation for 11 kW Heater Configuring the 6300 Control SystemGfci Wiring Diagram Gas Heater Hook up Preparing for Your New Portable Spa Never fill your spa with soft water Filling and Powering Up Your Portable Spa5100, 6200 and 6300 Electronic Control Operation Operating Your SpaDiagnostic Messages Meaning Setting Filtration CyclesLight OptionOperating Your Spa Initial Start-up Electronic Control OperationTime Standard, Economy, Sleep, and StandbySetting the Temperature Lock Preset Filter CyclesClean up Cycle InvertMessage Frequency Action Required Diagnostic Messages Meaning Action RequiredPeriodic Reminder Messages Dry Message Meaning Action RequiredOr --C StbyAuxiliary Control Operation Wireless Spa MonitorAuxiliary Panel Configuration Functions Air Venturis Adjustable Jets Diverter KnobsMulti-Colored Spa Light Operation Adjustable Therapy SystemAromatherapy WaterfallsCal Spas Clear Water Plan Water Quality MaintenanceAlternative Sanitation Options Before You BeginBather Load Chemical SafetyChemical Overview Physical Chemical HazardsFor use with any Clear Water Plan Chemical DescriptionsFor use with the Cal Clarity Bromine Generator For use with the chlorine Clear Water PlanFor use with the bromine Clear Water Plan Start Up Traditional Chemical Start Up Bromine Clear Water PlanDay One Monday Day Two WednesdayOzonator Clear Water Plan Chlorine Clear Water PlanDay One Monday Day Two WednesdayDay Two Friday Bromine Generator Clear Water PlanMaintenance Schedule Spa Cover Cleaning and MaintenanceRemoving and Reseating the Pillows Winterizing Cold Climate Draining Freeze damage is not covered by your warrantyDraining Your Portable Spa Cleaning the Cover, Shell and Pillows Exclusive Bio-Clean Filter Cartridge Cleaning and Replacing the FilterListening to the Radio Using the Entertainment SystemInserting and Ejecting a CD or Functions for Aeware DVD playerRaising and Lowering Playing a CDPlaying a Movie This applies to the Aeware system onlyUsing the Universal Remote Control Device Manufacturer Device Type Code Programming the Universal Remote ControlUsing the iPod Docking Station Appendix Replacement PartsMNW SXW Neck JET, Quad Blaster Power Storm JET, Swirley Pillows ValvesDrains WaterfallsFilters Replacement Cabinet PanelsPumps LED LightsClassic / Legacy Series CoversAvalon Series DIJ-404 93 x Family Series Fitness SeriesAppendix Ultimate Fitness Series Exercise Program Keeping Fit with your SpaConnecting the Exercise Equipment Cal Spas Chemicals Warranty Warranty Exclusions Warranty SpecificsWarranty Limitations Locating the product serial number

GFCI specifications

Cal Spas GFCI (Ground Fault Circuit Interrupter) is an essential safety feature incorporated in Cal Spas hot tubs and spas, designed to protect users from electrical shocks and enhance overall safety during relaxation. This advanced technology monitors the electrical current flowing through the spa's components, providing peace of mind for families and individuals enjoying their hydrotherapy experience.

One of the main features of the Cal Spas GFCI is its quick response time. The GFCI continuously measures the current balance between the hot and neutral wires. If it detects an imbalance, potentially caused by faulty wiring or a short circuit, it immediately trips the circuit, cutting off power to the unit within a fraction of a second. This rapid response significantly minimizes the risk of electrical accidents, making it a vital component for any outdoor or indoor spa setup.

Another key characteristic of the Cal Spas GFCI is its user-friendly design. The GFCI outlet is often equipped with a reset button, which allows users to quickly restore power once the issue has been addressed. This feature eliminates the need for complicated maintenance procedures, ensuring that users can enjoy their spa without frequent interruptions.

Incorporating state-of-the-art technology, Cal Spas GFCI is designed to withstand the rigors of outdoor environments. The durable exterior of the GFCI unit protects it from exposure to moisture, debris, and other potential hazards, leading to increased longevity and reliability. Moreover, the GFCI meets the highest safety standards and regulations, providing confidence to consumers that they are investing in a safe product.

Another highlight of the Cal Spas GFCI is its compatibility with a variety of hot tub configurations. This flexibility allows it to work seamlessly with different Cal Spas models, delivering consistent safety features across the entire range. Additionally, installation is straightforward, with many users opting for professional installation to ensure it is set up correctly.

In summary, Cal Spas GFCI enhances the safety of hot tub and spa experiences through its quick trip response, durable design, user-friendly functionalities, and compatibility with various models. By integrating this technology, Cal Spas demonstrates its commitment to providing a safe and enjoyable environment for relaxation and rejuvenation.