PRESETTING

Presseting Parameters

Presetting parameters, the unit can be tuned to be most suitable for each user.

Presettable Parameters

Bit rate (MPEG or PCM) assigned to each of SP/LP/ MP mode.

Threshold sound level to detect silence in silent skip mode.

Threshold time to detect silence in silent skip mode.

Battery Type

File format of recorded track.

ID1 (6 digits)

ID2 (6 digits)

ID3 (6 digits)

Parameter

Selectable Setting for

Default

 

the Parameter

Setting

 

 

 

Bit rate of SP

768, 192, 128, 96 kbps

192 kbps

 

 

 

Bit rate of MP

192, 128, 96, 48 kbps

96 kbps

 

 

 

Bit rate of LP

128, 96, 48,32 kbps

64 kbps

 

 

 

Sound level for silent skip

-50dB to -30dB, 1dB step

-40 dB

 

 

 

Silent time for silent skip

1 to 5 second, 1 second step

3 seconds

 

 

 

Battery type

Alkaline, Ni-Cad.

Alkaline

 

 

 

File format

WAVE, LPEG2, BWF

WAVE

 

 

 

ID1,2,3

000000 to 999999

000000

 

 

 

Note

ID1-3 is used to record ID numbers in the user blocks in BWF header.

For example, ID1 for ID of the broadcasting station, ID2 for the department code, ID3 for the budge number of the reporter. ID1, ID2, and ID3 are recorded in the "Broadcast Audio Extension" chunk of BWF as follows.

ID1: Description (the first 6 characters in 256 columns)

ID2: Originator (the first 6 characters in 32 columns)

ID3: Originator Reference (the first 6 characters in 32 columns)

Preset Operation

AUTO MARK

PRESET

1 / 4 ¢ / ¡

PLAY / PAUSE

(6)

STOP (7)

From standby (power off) status, turn power on while pressing MARK SELECT key. The unit enters preset mode.

Using 1/4 key or ¢/¡ key, select which parameter to be set

Parameter menu is displayed blinking cyclically as follows;

￿￿￿Bit rate for SP →

Bit rate for MP →

Bit rate for LP →

￿￿Sound level for silent skip →

Silent time for silent skip

￿￿￿￿Battery type →

File format →

ID1

ID2 ID3

1.While blinking, press PLAY/PAUSE key. Then the blinking parameter is selected as a parameter to be changed, and blinking of parameter stops to be stable on. Instead, settings for the parameter start to blink.

2.Using 1/4 key or ¢/¡ key, display the selectable settings.

3.Press PLAY/PAUSE key, displayed setting is assigned to the parameter .

4.After setting the value for the parameter, you can again select the parameter to be set using 1/4 key or ¢/¡ key. The parameter menu blinks.

(Return to item 1).

5.Pressing MARK/SELECT key, updated parameters are registered and become effective. The unit enters stop status.

6.Instead, pressing STOP key, update is not done. The preset values stay as it they were before entering preset menu. The unit enters stop status.

Nesting of Parameter Presetting Menu

Standby Status (Power off)

 

 

 

 

 

 

 

 

 

 

 

MARK SELECT

 

Stop Status

 

 

 

 

 

+POWER

 

 

DISPLAY

 

 

 

 

 

 

 

 

 

1/ 4, ¢/ ¡

 

 

 

 

Parameter Selection Menu

 

 

 

 

 

 

PLAY / PAUSE

 

 

PLAY / PAUSE

 

 

 

 

1/ 4, ¢/ ¡

 

 

 

 

Setting assign menu

 

 

 

 

 

 

Parameter Selection

Setting Selection

24

Image 24
Contents Features PrecautionsForeword IntroductionHow to Use this Manual ContentsNi-Cad Rechargeable Battery optional Batteries and AC AdaptorAlkaline Batteries AC adaptorPower On/Off Setting the Date and TimePower on Power OffUnderstanding PC Cards Inserting the card Formatting the PC cardOperation Ejecting the cardConnecting Microphones Connecting Analog ComponentsTo output analog audio signals to another audio component To record from or output through a telephone wireConnecting Digital Components Remote controlHeadphones Other ConnectionsCharging Battery Low Battery Warning and Auto Power OffDuring stop mode Data DisplayKeylock During playbackDuring Recording To Illuminate the Display PanelSelection and Manipulation of Input Source MIC AttenuationREC Level Recording Behavior Setting REC ModePRE REC Silent SkipRecording Operation Basic Operation PreparationStop Un-audible Fast Access Audible SeekRWD ReWinD Track Jump Track Count Up/DownTo cancel Repeat PlayRepeating a Track Repeating the Entire cardSummary of Accessing Behavior Next Track Jump Stop at the top of the next trackMarking and EDL Playback Marking OperationAccess to the Mark Editing MarkEDL Playback EDL Repeat PlaybackMeaning of Mark Definition Display during EDL playbackPlayback Control in EDL playback and in EDL Repeat playback PauseDisplay during pause while EDL Playback Deleting MarkInitialization of EDL Displaying Total Number of Marks PlacedDisplay at initialization of EDL Mark InconsistencyTrack Handling Track EraseRenumbering Track Number Display at Track Erase Operation EmbedPresettable Parameters Preset OperationPresseting Parameters Example of Presetting Operation Battery Type Presetting File Format PresettingID Number Presetting ID number setting operationDisplay at Parameter Selection Menu Error Handling Error DetectionCapacity of Card and Recording Time File ManagementTroubleshooting Digital audio system InputsOutputs GeneralIndex of Parts, Controls, and Display Top PanelFront Panel Top Pannel Front PannelLeft Panel Right PanelREC Display