Bryant 340MAV manuals
Household Appliance > Furnace
When we buy new device such as Bryant 340MAV we often through away most of the documentation but the warranty.
Very often issues with Bryant 340MAV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Furnace Bryant 340MAV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Furnace on our side using links below.
12 pages 322.16 Kb
USERS INFORMATION MANUAL MODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACEThis manual must be left with the equipment user. NOTE TO INSTALLER:2 WELCOME TO A NEW GENERATION OF COMFORTGENERAL FURNACE SAFETYCongratulations! In light of rising energy costs, the Plus 90 , 340MAV, Plus90t and Plus 90i MODELS 340MAV (SHOWN) AND 350MAV FIXED-CAPACITY FURNACES MODEL 355MAV VARIABLE-CAPACITY AND MODEL 352MAV TWO-STAGE FURNACES 3 FURNACE COMPONENTS MODELS 340MAV, 350MAV, AND 352MAV FURNACES (UPFLOW POSITION) MODEL 355MAV FURNACE (UPFLOW POSITION) 4 SAFETY CONSIDERATIONS BEFORE STARTING YOUR FURNACE STARTING AND SHUTTING DOWN YOUR FURNACE 5 STEPS FOR STARTING YOUR FURNACE 12 10 8 9 11 13 14 17 22 19 18 20 SHUTTING DOWN YOUR FURNACE 21 6 PERFORMING ROUTINE MAINTENANCE 7 FILTERING OUT TROUBLE 23 24 25 26 FURNACE AIR FILTER TABLE 9 COMBUSTION AREA AND VENT SYSTEM37 38 39 HEADING SOUTH FOR THE WINTER? DANGER 10 A CHECK-UP CHECKLIST BEFORE YOU REQUEST A SERVICE CALL
Also you can find more Bryant manuals or manuals for other Household Appliance.
Bryant 340MAV Instruction Manual
44 pages 588.97 Kb
installation, start-up, and operating instructions4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 340MAV Series D2 Fig. 2Dimensional DrawingDIMENSIONS (IN.)For airflow requirements above 1800 CFM, use both side inlets, a 4. 3. 2. 1. NOTES: Minimum return-air opening at furnace:060100 21 19-3/8 19-1/2 048100 21 19-3/8 19-1/2 060080 21 19-3/8 19-1/2 048080 17-1/2 15-7/8 16 036080 17-1/2 15-7/8 16 048060 17-1/2 15-7/8 16 036060 17-1/2 15-7/8 16 024060 17-1/2 15-7/8 16 036040 17-1/2 15-7/8 16 024040 17-1/2 15-7/8 16 UNIT SIZE A D E 060120 24-1/2 22-7/8 23 060140 24-1/2 22-7/8 23 combination of 1 side inlet and the bottom, or the bottom only. 3 1103003001 10030 0 14 TABLE 1OPENING DIMENSIONS (IN.)Fig. 13Floor and Plenum Opening Dimensions Fig. 14Furnace, Plenum, and Subbase Installed on a Combustible Floor Fig. 15Furnace, Plenum, and Coil Assembly or Coil Box Installed on a Combustible Floor Fig. 24Wiring Diagram NOTE #4 10. BLOWER-OFF DELAY, GAS HEATING 90, 135, 180 OR 225 SECONDS, COOLING OR 9. BLOWER-ON DELAY, GAS HEATING 60 SECONDS, COOLING OR HEAT PUMP 2 SECONDS. 8. YELLOW LEAD NOT ON ALL MOTORS. 7. REPLACE ONLY WITH A 3 AMP FUSE. 2. INDUCER (IDM) AND BLOWE R (BLWM) MOTORS CONTAIN INTERNAL 1. IF ANY OF THE ORIGINAL EQUIPMENT WIRE IS REPLACED USE WIRE RATED FOR 105C. NOTES:TO 115VAC FIELD DISCONNECT GVR HSIR IDR BL WR 225 SEC 180 SEC 135 SEC 90 SEC 19 PCB 44 SERVICE TRAINING
48 pages 606.25 Kb
ama installation, start-up, and operating instructions4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE 340MAV Series J3 Fig. 2Dimensional DrawingDIMENSIONS (IN.)combination of 1 side and the bottom, or the bottom only will ensure adequate literature for specific use of single side inlets. The use of both side inlets, a d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data c. For 1600 CFM22-in. round or 14 b. For 1200 CFM20-in. round or 14 a. For 800 CFM16-in. round or 14 NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, 060140 24-1/2 22-7/8 23 060120 24-1/2 22-7/8 23 060100 21 19-3/8 19-1/2 048100 21 19-3/8 19-1/2 060080 21 19-3/8 19-1/2 048080 17-1/2 15-7/8 16 036080 17-1/2 15-7/8 16 048060 17-1/2 15-7/8 16 036060 17-1/2 15-7/8 16 024060 17-1/2 15-7/8 16 036040 17-1/2 15-7/8 16 024040 17-1/2 15-7/8 16 UNIT SIZE A D EA02147 x 23 x 19 x 12-in. rectangle. -in. rectangle. return air openings for airflow requirements above 1800 CFM at 0.5 W.C. ESP. MINIMUM INCHES CLEARANCE TO COMBUSTIBLE CONSTRUCTION 4 *20 Fig. 30Wiring Diagram NOTE #2 11. Factory connected when L G P S is not use d. 8. Neu tral connections are interchangeable with in the NEUTRAL connector block. 6. Rep lace only with a 3 amp fuse. 5. So lid lines inside PCB are printed circui t board conductors and are not included in legend . 4. Symbols are electrical representation only. 3. Th is wire must be connected to furnace sheet metal for control to prove flame. 2. Use only copper wire between the disconnect switch and the furnace junction box (JB). 1. I f any of the original equipment wire is repl aced use wire rated for 105C. NOTES:TO 115VAC FIELD DISCONNECT 21 PCB
Also you can find more Bryant manuals or manuals for other Household Appliance.