Bryant 340MAV instruction manual Maximumallowable Pipe Length Ft

Models: 340MAV

1 48
Download 48 pages 30.25 Kb
Page 27
Image 27

TABLE 7—MAXIMUM ALLOWABLE PIPE LENGTH (FT)

ALTITUDE (FT)

UNIT SIZE

TERMINATION

PIPE DIA

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

2

 

3

4

5

6

 

 

 

 

024040

2 Pipe or 2-in

1

5

NA

 

NA

NA

NA

NA

 

 

 

 

 

 

 

 

 

 

1-1/2

70

70

 

65

60

60

55

 

036040

Concentric

 

 

 

 

 

 

 

 

 

 

 

2

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024060

2 Pipe or 2-in

1-1/2

20

15

 

10

5

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

Concentric

2

70

70

 

70

70

70

70

 

048060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-in

1-1/2

10

NA

 

NA

NA

NA

NA

 

048080

2

55

50

 

35

30

30

20

 

Concentric

 

 

060080

 

 

 

 

 

 

 

 

 

2-1/2

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 to 2000

048100

2 Pipe or 3-in

2

5

NA

 

NA

NA

NA

NA

 

2-1/2

40

30

 

20

20

10

NA

 

060100

Concentric

 

 

 

 

 

 

 

 

 

 

 

3

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Pipe or 3-in.

2-1/2 one disk

10

NA

 

NA

NA

NA

NA

 

060120

3†

45

40

 

35

30

25

20

 

Concentric

 

 

 

3† no disk

70

70

 

70

70

70

70

 

 

 

 

 

 

 

2-1/2 one disk

5

NA

 

NA

NA

NA

NA

 

060140

2 Pipe or 3-in.

3† one disk

40

35

 

30

25

20

15

 

Concentric

3† no disk

60

56

 

52

48

44

40

 

 

 

 

 

 

4† no disk

70

70

 

70

70

70

70

ALTITUDE (FT)

UNIT SIZE

TERMINATION

PIPE DIA

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

2

 

3

4

5

6

 

 

 

 

024040

2 Pipe or 2-in

1-1/2

67

62

 

57

52

52

47

 

Concentric

2

70

70

 

70

70

70

70

 

036040

 

 

 

1–1/2

17

12

 

7

NA

NA

NA

 

 

 

 

 

024060

2 Pipe or 2-in

 

 

 

 

 

 

 

 

 

036060

Concentric

2

70

67

 

66

61

61

61

 

048060

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-in

2

49

44

 

30

25

25

15

 

048080

 

 

 

 

 

 

 

 

 

Concentric

2-1/2

70

70

 

70

70

70

70

2001 to 3000

060080

 

 

 

048100

2 Pipe or 3-in

2–1/2

35

26

 

16

16

6

NA

 

 

 

060100

Concentric

3

70

70

 

70

70

66

61

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Pipe or 3-in.

3

14

9

 

NA

NA

NA

NA

 

 

 

 

 

 

 

 

 

 

 

060120

3† no disk

70

70

 

63

56

50

43

 

Concentric

 

 

 

 

 

 

 

 

 

 

 

 

 

4† no disk

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 Pipe or 3-in.

3† one disk

20

15

 

10

5

NA

NA

 

 

 

 

 

 

 

 

 

 

 

060140

3† no disk

39

35

 

31

27

23

19

 

Concentric

 

 

 

 

 

 

 

 

 

 

 

 

 

4† no disk

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE (FT)

UNIT SIZE

TERMINATION

PIPE DIA

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

2

 

3

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024040

2 Pipe or 2-in

1-1/2

64

59

 

54

49

48

43

 

036040

Concentric

2

70

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

024060

2 Pipe or 2-in

1–1/2

16

11

 

6

NA

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

Concentric

2

68

63

 

62

57

57

56

 

048060

 

 

 

 

 

036080

2 Pipe or 2-in

2

46

41

 

28

23

22

13

 

048080

 

 

 

 

 

 

 

 

 

Concentric

2-1/2

70

70

 

70

70

70

70

3001 to 4000

060080

 

 

 

048100

2 Pipe or 3-in

2-1/2

33

24

 

15

14

5

NA

 

 

 

060100

Concentric

3

70

70

 

70

66

61

56

 

060120

2 Pipe or 3-in.

3† no disk

65

58

 

51

44

38

31

 

Concentric

4† no disk

70

70

 

70

70

70

70

 

 

 

 

 

2 Pipe or 3-in.

3† one disk

11

6

 

NA

NA

NA

NA

 

060140

3† no disk

30

26

 

22

18

14

10

 

Concentric

 

 

 

4† no disk

70

70

 

70

70

70

70

 

 

 

 

See notes at end of table

—27—

Page 27
Image 27
Bryant 340MAV instruction manual Maximumallowable Pipe Length Ft