ROOF ″ 18 MAXIMUM
BRACKET
COUPLING
VERTICAL SEPARATION
BETWEEN COMBUSTIONVENT AIR AND VENT
8 3/4″ FOR 3″ KIT
6 3/4″ FOR 2″ KIT
MAINTAIN 12 IN. MINIMUM
CLEARANCE ABOVE HIGHEST
ANTICIPATED SNOW LEVEL.
MAXIMUM OF 24 IN. ABOVE ROOF.
Fig. 36—Roof Termination (Preferred)
VENT
COMBUSTION
AIR
A87224
OVERHANG OR ROOF
12″ MINIMUM
1″ MAXIMUM
VENT
MAINTAIN 12 IN. (18 IN. FOR CANADA) MINIMUM CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL. MAXIMUM OF
24 IN. ABOVE ROOF.
COMBUSTION AIR
A93054
MAINTAIN 12 IN.
CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL OR GRADE, WHICHEVER IS GREATER.
A93055
Fig. 37—Concentric Vent and Combustion-Air Roof
Termination (Preferred)
OVERHANG OR ROOF
12″ MINIMUM
VENT
90°
BRACKET
12 IN. SEPARATION BETWEEN BOTTOM OF COMBUSTION AIR AND BOTTOM OF VENT
MAINTAIN 12 IN.
CLEARANCE
ABOVE HIGHEST
ANTICIPATED SNOW
LEVEL OR GRADE,
GREATER.
A87225
Fig. 38—Concentric Vent and Combustion-Air Side
Termination
OVERHANG OR ROOF
12″ MINIMUM
VENT
90°
BRACKET
COUPLING
| 12 IN. SEPARATION |
| BETWEEN BOTTOM OF |
| COMBUSTION AIR AND |
| BOTTOM OF VENT |
| MAINTAIN 12 IN. |
| CLEARANCE |
| ABOVE HIGHEST |
| ANTICIPATED SNOW |
LEVEL OR GRADE, | |
(ELBOW PARALLEL | WHICHEVER IS |
TO WALL) | GREATER. |
| A87226 |
Fig. | Fig. |