Bryant 340MAV instruction manual FOR USE WITH 140 SIZE FURNACES ONLY

Models: 340MAV

1 48
Download 48 pages 30.25 Kb
Page 41
Image 41

TABLE 10—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

FOR USE WITH 140 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 23,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

850

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.8

 

 

 

875

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.7

41

 

3.8

Canada

 

 

900

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

 

0

925

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

 

 

950

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

and

 

to

975

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

 

1000

43

 

3.5

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

U.S.A.

 

 

 

 

 

 

 

 

2000

1025

43

 

3.3

43

 

3.4

43

 

3.6

43

 

3.7

43

 

3.8

 

 

1050

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

 

 

 

 

 

 

 

 

0%

1075

44

 

3.5

44

 

3.6

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

1100

44

 

3.3

44

 

3.4

44

 

3.5

43

 

3.2

43

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

U.S.A.

775

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.7

39

 

3.6

 

 

Altitudes

800

42

 

3.8

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

Canada

 

2001to

825

42

 

3.6

42

 

3.7

41

 

3.5

41

 

3.6

41

 

3.7

 

3000

850

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

41

 

3.5

 

or

875

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

and

 

Canada

900

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

Altitude

925

43

 

3.5

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

U.S.A.

 

 

 

 

 

 

 

2001 to

950

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.7

43

 

3.8

 

4500

975

43

 

3.1

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

 

 

 

 

 

 

 

5%

1000

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

1025

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

750

41

 

3.6

41

 

3.8

40

 

3.6

40

 

3.7

40

 

3.8

 

 

 

775

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.7

40

 

3.6

 

 

 

800

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

Only

 

3001

825

42

 

3.3

42

 

3.4

42

 

3.6

42

 

3.7

42

 

3.8

 

 

850

43

 

3.8

42

 

3.2

42

 

3.4

42

 

3.5

42

 

3.6

U.S.A.

 

to

875

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

42

 

3.4

 

 

900

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.8

42

 

3.2

 

4000

925

43

 

3.2

43

 

3.3

43

 

3.5

43

 

3.6

43

 

3.7

 

 

 

 

 

 

 

 

 

 

950

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

 

 

7%

975

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

 

 

derate

1000

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.0

43

 

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Orifice numbers shown in BOLD are factory installed.

Percents of derate are based on midpoints of U.S. altitude ranges.

—41—

Page 41