TABLE 9—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

850

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

 

 

875

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.2

Canada

 

 

900

44

 

3.7

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

 

0

925

44

 

3.5

44

 

3.7

44

 

3.8

43

 

3.4

43

 

3.5

 

 

950

44

 

3.4

44

 

3.5

44

 

3.6

44

 

3.7

44

 

3.8

and

 

to

975

44

 

3.2

44

 

3.3

44

 

3.4

44

 

3.5

44

 

3.6

 

 

1000

45

 

3.7

45

 

3.8

44

 

3.2

44

 

3.4

44

 

3.5

U.S.A.

 

 

 

 

 

 

 

 

2000

1025

45

 

3.5

45

 

3.6

45

 

3.7

44

 

3.2

44

 

3.3

 

 

1050

45

 

3.3

45

 

3.4

45

 

3.6

45

 

3.7

45

 

3.8

 

 

 

 

 

 

 

 

 

 

0%

1075

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

45

 

3.6

 

 

derate

1100

47

 

3.6

47

 

3.7

45

 

3.2

45

 

3.4

45

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

U.S.A.

775

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

 

 

Altitudes

800

43

 

3.5

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

Canada

 

2001 to

825

44

 

3.8

43

 

3.4

43

 

3.6

43

 

3.7

43

 

3.8

 

3000

850

44

 

3.6

44

 

3.7

44

 

3.8

43

 

3.5

43

 

3.6

 

or

875

44

 

3.4

44

 

3.5

44

 

3.6

44

 

3.7

43

 

3.4

and

 

Canada

900

44

 

3.2

44

 

3.3

44

 

3.4

44

 

3.5

44

 

3.6

 

Altitudes

925

45

 

3.7

45

 

3.8

44

 

3.2

44

 

3.3

44

 

3.4

U.S.A.

 

 

 

 

 

 

 

2001 to

950

45

 

3.5

45

 

3.6

45

 

3.7

45

 

3.8

44

 

3.3

 

4500

975

45

 

3.3

45

 

3.4

45

 

3.5

45

 

3.6

45

 

3.8

 

 

 

 

 

 

 

 

 

5%

1000

45

 

3.1

45

 

3.2

45

 

3.4

45

 

3.5

45

 

3.6

 

 

derate

1025

45

 

3.0

45

 

3.1

45

 

3.2

45

 

3.3

45

 

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

750

43

 

3.7

43

 

3.8

42

 

3.3

42

 

3.4

42

 

3.5

 

 

 

775

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.2

 

 

 

800

44

 

3.7

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

Only

 

3001

825

44

 

3.5

44

 

3.6

44

 

3.8

43

 

3.4

43

 

3.5

 

 

850

44

 

3.3

44

 

3.4

44

 

3.5

44

 

3.7

44

 

3.8

U.S.A.

 

to

875

45

 

3.8

44

 

3.2

44

 

3.3

44

 

3.5

44

 

3.6

 

 

900

45

 

3.6

45

 

3.7

45

 

3.8

44

 

3.3

44

 

3.4

 

4000

925

45

 

3.4

45

 

3.5

45

 

3.6

45

 

3.7

44

 

3.2

 

 

 

 

 

 

 

 

 

 

950

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

45

 

3.7

 

 

7%

975

45

 

3.0

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

 

 

derate

1000

45

 

2.9

45

 

3.0

45

 

3.1

45

 

3.2

45

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Orifice numbers shown in BOLD are factory installed.