TABLE 10—MODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

(Continued)

 

 

 

 

 

 

FOR USE WITH 140 SIZE FURNACES ONLY

 

 

 

 

 

 

 

(TABULATED DATA BASED ON 23,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

725

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.8

 

 

 

750

42

 

3.7

42

 

3.8

41

 

3.6

41

 

3.7

41

 

3.8

Only

 

4001

775

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

41

 

3.6

 

 

800

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

 

 

 

 

 

 

 

 

U.S.A.

 

to

825

43

 

3.7

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

 

5000

875

43

 

3.3

43

 

3.4

43

 

3.6

43

 

3.7

43

 

3.8

 

 

 

850

43

 

3.5

43

 

3.6

43

 

3.8

42

 

3.2

42

 

3.3

 

 

 

900

43

 

3.1

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

9%

925

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

950

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

700

41

 

3.5

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.7

 

 

 

725

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.8

 

 

 

750

42

 

3.4

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

 

 

 

775

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.7

Only

 

5001

800

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

 

825

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.2

 

 

 

 

 

 

 

 

U.S.A.

 

to

850

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

 

 

875

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

 

 

 

 

 

 

 

 

 

 

6000

900

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

 

 

 

925

43

 

2.7

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

 

 

 

950

43

 

2.6

43

 

2.7

43

 

2.8

43

 

2.9

43

 

3.0

 

 

11%

975

43

 

2.5

43

 

2.6

43

 

2.6

43

 

2.7

43

 

2.8

 

 

derate

1000

43

 

2.3

43

 

2.4

43

 

2.5

43

 

2.6

43

 

2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

650

41

 

3.8

40

 

3.6

40

 

3.7

40

 

3.8

39

 

3.7

 

 

 

675

41

 

3.5

41

 

3.6

41

 

3.7

40

 

3.6

40

 

3.7

Only

 

6001

700

42

 

3.6

42

 

3.7

41

 

3.5

41

 

3.6

41

 

3.7

 

 

725

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

 

 

 

 

 

 

 

 

U.S.A.

 

to

750

43

 

3.8

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

 

7000

800

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

43

 

3.8

 

 

 

775

43

 

3.6

43

 

3.7

43

 

3.8

42

 

3.3

42

 

3.4

 

 

 

825

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

13%

850

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

derate

875

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Orifice numbers shown in BOLD are factory installed.

Percents of derate are based on midpoints of U.S. altitude ranges.

—42—

Page 42
Image 42
Bryant 340MAV instruction manual Continued, FOR USE WITH 140 SIZE FURNACES ONLY