2. WIRING

2.5Changing AC Power Specification of Processor Unit

To change AC power specification between 100 VAC and 220 VAC, add or remove jumper connector P108 on the PWR board 03P9339 and change the fuse on the processor unit according to ship’s mains as shown in the table below. The figures below and on the next page show the location of the fuse and the jumper connector on the PWR board. Also, adjustment of the overvoltage detection circuit is required.

Note: To change from 200 VAC to 100 VAC, locally prepare the jumper connector, referring to the figure shown on the next page (VH8P connector housing is fitted at J108).

Power supply

Fuse

Jumper connector

 

 

 

100 VAC

10A

Added

 

 

 

220 VAC

5A

Removed

 

 

 

Cover of PWR board

Fuse

PWR board

Upper part of processor unit (SPU assembly omitted)

2-12

Page 36
Image 36
Furuno FAR-2827, FAR-2127-BB, FAR-2117-BB, FAR-2817 installation manual Changing AC Power Specification of Processor Unit