4. INSTALLING OPTIONAL EQUIPMENT

Location of DIP switches, jumper wires on the GYRO CONVERTER board

JP5, JP4 (Supply voltage)

JP2 (Stator voltage)

JP3 (Rotor voltage)

JP1

64P1106

(Gyro type)

SW3

DIP switch J12

(Data output port #6)

Fuse

 

SW1

 

(2A)

J4

 

DIP switch

 

J5

(Stator signal input)

J6

 

 

J8

J11

(Data output port #5)

J10

(Data output port #4)

SW2

DIP switch

JP6, JP7 (AD format

data Tx interval)

J9

(Data output port #3)

(Rotor signal input,

(IEC-61162-1 output port)

external power input)

 

(Data output port #2)

J7

(Data output port #1)

GYRO CONVERTER board

Setting the heading readout on the radar display

Confirm that the gyrocompass is giving a reliable readout. Then, set the heading readout on the radar display with the gyrocompass readout as follows:

1.Roll the trackball to place the arrow in the HDG box at the top right corner of the screen.

2.Push the right button on the trackball module to open the HDG menu.

[HDG MENU]

1 HDG SOURCE AD-10/SERIAL

2GC-10 SETTING 000.0˚

HDG menu

3.Press the [1] key to choose the HDG SOURCE and choose AD-10.

4.Press the [2] key to choose the GC-10 SETTING option.

5.Roll the wheel to set gyrocompass reading.

6.Press the [MENU] key to close the menu.

4-8

Page 68
Image 68
Furuno FAR-2117-BB, FAR-2827, FAR-2127-BB Setting the heading readout on the radar display, Gyro Converter board, HDG menu