4. INSTALLING OPTIONAL EQUIPMENT
Setting method 1: DIP switch settings and gyrocompass specifications
1) Gyrocompass type
Gyrocompass | SW | SW | SW | JP1 | |
type | |||||
| |||||
|
|
|
|
| |
AC | OFF | OFF | OFF | #1, #2, | |
synchronous | #3 | ||||
DC | OFF | OFF | OFF | #2, #3, | |
synchronous | #4 | ||||
DC step | ON | OFF | OFF | #4, #5, | |
#6 | |||||
OFF | ON | OFF | #4, #5, | ||
pulsating current | #6 | ||||
ON | ON | OFF | #4, #5, | ||
pulsating current | #6 |
2) Frequency
Frequency | SW | SW | Remarks | |
|
| |||
|
|
|
| |
50/60 Hz | OFF | OFF | AC synchronous | |
pulsating current | ||||
400 Hz | ON | OFF | AC synchronous | |
pulsating current | ||||
500 Hz | OFF | ON | AC synchronous | |
pulsating current | ||||
|
|
| ||
DC | ON | ON | DC synchronous | |
DC step | ||||
|
|
|
3) Rotor Voltage (between R1 & R2) | 4) Stator Voltage (between S1 & S2) |
Rotor Voltage | SW | JP3 | |
|
| ||
|
|
| |
20 to 45 VAC | ON | #2 | |
|
|
| |
30 to 70 VAC | OFF | #2 | |
|
|
| |
40 to 90 VAC | ON | #1 | |
|
|
| |
60 to 135 VAC | OFF | #1 | |
|
|
|
Stator | SW | SW | JP2 | |
Voltage | ||||
| ||||
|
|
|
| |
20 to 45 VAC, or | ON | OFF | #2 | |
20 to 60 VDC | ||||
|
|
| ||
30 to 70 VAC, or | OFF | OFF | #2 | |
40 to 100 VDC | ||||
|
|
| ||
40 to 90 VAC | ON | OFF | #1 | |
|
|
|
| |
60 to 135 VAC | OFF | OFF | #1 | |
|
|
|
|
5) Ratio
Ratio | SW | SW | SW | |
| ||||
|
|
|
| |
360X | OFF | OFF | OFF | |
|
|
|
| |
180X | ON | OFF | OFF | |
|
|
|
| |
90X | OFF | ON | OFF | |
|
|
|
| |
36X | ON | ON | OFF | |
|
|
|
|
6) Supply Voltage
Stator |
| JP4 | JP5 |
Voltage |
| ||
|
|
| |
|
|
|
|
20 to 45 | VAC, or 20 to 60 VDC | #2 | #2 |
|
|
|
|
30 to 70 | VAC, or 40 to 100 VDC | #1 | #1 |
|
|
|
|
7)AD-10 format data Tx interval
Select data transmitting interval for ports 1 to 6 with jumper wires JP6 and JP7: #25 for 25 ms, #200 for 200 ms.
Note: The Tx interval is available in 25 msec or 200 msec.
Use 25 msec for radar.
8)
Tx interval and Output sentence
Tx | SW | SW | Output |
interval | sentence | ||
|
|
|
|
1 s | OFF | OFF | HDT+VHW |
200 ms | ON | OFF | HDT |
100 ms | OFF | ON | HDT |
25 ms | ON | ON | HDT |
9)
Version no.
1.5OFF
2.0ON
10)
Baud rate | |
4860bps | OFF |
38400bps | ON |
11)Power fail detection
Talker | |
Disable | OFF |
Enable | ON |
(Use OFF for radar.)
12)Stator signal breaking detection
Detection | |
Execute | OFF |
No execute | ON |