2. WIRING

2.4Processor Unit

Four cables are terminated at the processor unit: the antenna unit cable, display unit cable, control unit cable and the power cable. Cables other than the power cable come with a connector preattached to them for connection to the processor unit. Fabricate the power cable as below. For the power cable, use DPYC-2.5 (Japan Industry Standard) cable for AC unit or DPYC-6 for DC unit, or the equivalent.

Note: For AC unit

Pass the AC line through a double-contact breaker (shipyard supply).

Fabricating the power cable

1.Cut armor of the cable by 40 mm.

2.Cut vinyl sheath by 35 mm.

3.Remove insulation of wires by about 10 mm. Fix crimp-on lugs to the cores.

4.Peel paint of the armor by 40 mm.

5.Cover the end of armor with vinyl tape.

(a) DPYC-2.5

Armor

Approx. 40 mm

35 mm

(b)

Vinyl sheath

10 mm

(c)

40 mm: Peel paint.

(d)

Taping

Armor

Conductor of DPYC-2.5

2.5mm

φ= 2.01 mm2=S

Conductor of DPYC-6

S φ

= =

6.0 mm

2

 

3.12 mm

(sectional view)

Fabricating power cable DPYC

2-7

Page 31
Image 31
Furuno FAR-2127-BB, FAR-2827, FAR-2117-BB, FAR-2817 installation manual Processor Unit, Fabricating power cable Dpyc