Furuno FAR-2127-BB, FAR-2827, FAR-2117-BB, FAR-2817 How to adjust the overvoltage detection circuit

Models: FAR-2127-BB FAR-2117-BB FAR-2127 FAR-2827 FAR-2117 FAR-2817

1 135
Download 135 pages 9.16 Kb
Page 37
Image 37

2. WIRING

J105

J106

(P)HV

PWR board

 

J104

 

 

J103

R21

 

 

(OVER)

 

 

P108/J108

 

J101

 

AC FIL

 

 

8 7 6 5 4 3 2 1

 

 

Jumper connector

 

 

(VH8P)

 

 

How to adjust the overvoltage detection circuit:

1.Add or remove the jumper connector P108 and change the fuse.

2.Rotate R21 fully clockwise on the PWR board.

3.Connect a variable transformer between ship's mains and the input power terminal board TB-1 of the processor unit.

4.Adjust the variable transformer output (i.e., input voltage to the processor unit) as follows. For 100 VAC set: 144 VAC

For 220 VAC set: 288 VAC

5.Turn on the radar and rotate the R21 counterclockwise gradually until the overvoltage detection circuit functions (i.e., power supply cuts off).

6.Lower the output voltage of the variable transformer and confirm that the radar automatically turn on with a voltage lower than 142VAC or 284VAC.

7.Gradually increase the output voltage of the variable transformer and confirm that the overvoltage detection circuit functions at 144V or 288VAC of the variable transformer output.

8.Assemble and connect the processor unit.

2-13

Page 37
Image 37
Furuno FAR-2127-BB, FAR-2827, FAR-2117-BB, FAR-2817 installation manual How to adjust the overvoltage detection circuit