2. WIRING
Cable fabrication for the cables connected to the 03P9342 board
ξ Signal cable
Vinyl sheath | Armor | Shield | |
|
|
|
|
|
|
|
|
|
|
|
|
60
5
450
Vinyl tape | After exposing cores, |
| |
| wind shield around the armor. |
| |
| 6 |
| |
|
| 14 5 9 | |
| Coaxial cable | Conductor | |
Clamp here by cable clamp. | Fold back shield. | ||
Coaxial cable | |||
|
|
ξ Other cables for optional units
Use
Armor
Sheath
Shield
φ = 10.1 mm
Conductor
S= 0.75 mm2 φ = 1.11 mm
TTYCS-1
Armor |
| 60: Peel paint. |
|
| |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
5
φ= 16.3 mm
Armor
Sheath
Shield
Conductor
S= 0.75 mm2 φ = 1.11 mm
TTYCS-4
Shield
L= Depends on equipment
Lconnected. Measure at
the processor unit.
Vinyl tape
After exposing cores,
wind shield around the armor.
6
Clamp here by cable clamp.
Wiring for WAGO connector
Press downward.
Terminal opener
Wire
WAGO connector
Twist
Procedures
1.Twist the conductor.
2.Press the terminal opener downward.
3.Insert the wire to hole.
4.Remove the terminal opener.
5.Pull the wire to confirm that it is ecure.
Wiring for Coaxial cable
Clamp shied with bracket.
Tighten conductor with screw.
CAUTION
Do not use