Furuno FE-700 manuals
Computer Equipment > Printer
When we buy new device such as Furuno FE-700 we often through away most of the documentation but the warranty.
Very often issues with Furuno FE-700 begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Printer Furuno FE-700 is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Printer on our side using links below.
44 pages 999.49 Kb
Also you can find more Furuno manuals or manuals for other Computer Equipment.
Furuno FE-700 Installation Manual
60 pages 2.68 Mb
Installation Manual NAVIGATIONAL ECHO SOUNDER FE-700 3 SAFETY INSTRUCTIONS 4 EQUIPMENT LISTS Standard Supply Optional Supply 6 SYSTEM CONFIGURATION 7 1. MOUNTING 17 2. WIRING MJ-A10SPF0002-100Distribution box FE-702 Ground Alarm system Wiring Ship's mains Navigation Device (IEC 61162-1) Personal computer (EIA-232C)Digital depth indicator FE-720 (option) Display unit FE-701 (rear panel) CONE board 02P6283 FE-702 Top view 12 CONE board 02P6283Ground Display unit FE-701 (rear panel) Ship's mains Alarm system Personal computer (EIA-232C) Navigation Device (IEC 61162-1)Distribution box FE-702 Digital depth indicator FE-720 (option) TRANSDUCER SWITCH BOX *3 EX-8 (option) Ground FE-702 Top viewFM-C6FPS003-020 MJ-A10SPF0002-100 18 *3: Connection of Distribution Box MB-1200(option)GND DISTRIBUTION BOX MB-1200 19 Cable Fabrication of DPYCYS-2.5, DPYCYS-1.5, MJ-A3SPF0015-100C , FM-C6FPS0002-100 and TPYCYS-1.5 DPYCYS-2.5, DPYCYS-1.5, TPYCYS-1.5 Others Fabrication of cables 21 Cable Fabrication of TTYCYS-4 24 Alarm system connection DPYCYS-1.5 1 2 1 3 NORMAL CLOSE NORMAL OPEN RELAY COMMON TB1 Select either one. Alarm System Digital Depth Indicator FE-720 There are two methods to connect the digital depth Indicator FE-720. Case 1: Input signal from the main display unit to FE-720 The interconnection is as follows. DISTRIBUTION BOX FE-702 DIGITAL DEPTH INDICATOR FE-720 25 Case2: Silencing the alarm from the digital depth indicator FE-720 Connection DISTRIBUTION BOX FE-702 DIGITAL DEPTH INDICATOR FE-720 Note: In this case, a positioning device can not be connected. FE-720 setting MENU DIM CONTROL PANEL ONLY /LANG. ENGLISH UNITS ALARM SET ON TEST 26 3. CHANGING POWER SPECIFICATIONS 200-230 VAC (50/60 Hz) 100-115 VAC (50/60 Hz) 24 VDC Label inside the distribution box FE-702 100 VAC, 110-115 VAC, 200 VAC Ship's Mains 27 24 VDC Ship's Mains 28 4. ADJUSTMENTS 4.1 Transducer Setting 30 4.2 Setting the Time TIME ADJUST set to EXTERNAL TIME DIFFERENCE set to MANUAL 1. Open the system menu 2 referring to the operators manual. Select other mode to exit. -2 -1(2 ('('*- 0#/' 176.+0' &'5%4+26+10%1&' 36; 31 ('('*- 70+6 #%%'5514+'5 (2 +056#..#6+10/#6'4+#.5 %2 &1%7/'06 (+: 32 -4-3 -6 -5(2 ('('*- 0#/' 176.+0' &'5%4+26+10%1&' 36; 33 D 58 S-1651,50/60Hz DISTRIBUTION BOX FE-701 NAVIGATIONAL ECHO SOUNDERFE-720 *6. REFER TO FE-720 INTERCONNECTION DIAGRAM FOR DETAIL. 200kHz 50kHz *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. FE-700 INTERCONNECTION DIAGRAM C2366-C01- N DISPLAY UNITMATCHING BOX MB-504(200B-8B) MATCHING BOX MB-502(50B-6B) MB-504(200B-8B) DISTRIBUTION BOX MB-1200 ALARM RELAY NORMAL CLOSE/OPEN PC (EIA-232C) OR PRINTER PP-505-FE NAV EQUIPMENT IEC61162-1 DEPTH INDICATOR 24 VDC FE-702100/110-115/ 200/220-230 VAC, FE-700 59 S-2INDICATOR DIGITAL DEPTH INDICATOR02-129-1004- 0 C2366-C02- KTERMINAL BOX FE-702 DISTRIBUTION BOX DS-802 DS-802 INDICATOR DIGITAL DEPTH DIGITAL DEPTH TERMINAL BOX FE-720 INTERCONNECTION DIAGRAM *3. FITTED AT FACTORY. *2. OPTION. *1. SHIPYARD SUPPLY. *4. REMOVE RESISTANCE 3k FOR USING 200V SET. 200V3k PP-505-FE 60 S-3PRINTER INTERCONNECTION DIAGRAMFE-702 DISTRIBUTION BOX *3: GROUND THRU CONNECTOR CLAMP. 16-006-3022-0 PRINTER C2366-C03- E*2: FITTED AT FACTORY. *1: SHIPYARD SUPPLY.
Also you can find more Furuno manuals or manuals for other Computer Equipment.