F type

Flush Mount Kit (F):

OP02-79-1 (001-229-290)

 

 

 

 

OP02-79-2 (001-229-300)

 

 

 

 

OP02-79-3 (001-229-310)

 

 

No.

Name

 

Type

Code no.

Qty

Remarks

1

Cosmetic

 

02-129-1041-0

100-279-270

1

OP02-79-1:N3.0

 

100-279-280

OP02-79-2:2.5GY5/1.5

panel

 

 

 

 

100-279-290

 

OP02-79-3:7.5GY7/2

 

 

 

 

 

2

Hex bolt

 

M6x12

000-162-897-1

4

 

 

0

 

 

 

 

 

 

 

3

Spring

 

M6

000-158-855-1

4

 

washer

 

0

 

 

 

 

 

 

1.Prepare a cutout in the mounting location whose dimensions are 210 (W) x 194 (H) mm.

2.Attach the cosmetic panel (02-129-1041-0) to the display unit with four hex bolts (M6x12) and four spring washers (M6).

3.Fix the display unit to the mounting location with four tapping screws (5x20).

S type

Flush Mount Kit (S):

OP02-80 (001-229-320)

 

 

No.

Name

Type

Code no.

Qty

Remarks

1

Fixing plate

02-129-1045-0

100-279-300

2

 

2

Wing bolt

M4x30

000-804-799

6

 

3

Hex bolt

M6x12

000-162-897-1

4

 

0

 

 

 

 

 

 

4

Spring

M6

000-158-855-1

4

 

washer

0

 

 

 

 

 

5

Wing nut

M4

000-863-306

6

 

1.Prepare a cutout in the mounting location whose dimensions are 194 x 194 mm.

2.Insert the display unit to the cutout.

3.Attach two fixing plates (02-129-1045-0) to the display unit with four hex bolts (M6x12) and spring four washers (M6).

4.Screw six wing bolts (M4x30) to wing nuts (M4).

5. Fasten the display unit with six wing bolts and nuts.

1.3 Transducer

The installation of the transducer and the tank should be accomplished by a dockyard referring to the installation drawings at the back of this manual. An example of transducer installation method is also shown in paragraph 1.3.2.

Note: Discussions should take place and agreement reached with the dockyard for sufficient reinforcement and watertightness of the hull to comply with the regulations concerned.

4

Page 10
Image 10
Furuno FE-700 installation manual Transducer, Type