Note: If CHANGEOVER is set for MANUAL, select SINGLE.

 

0

 

 

0

 

20

 

 

20

 

40

 

 

40

 

60

 

 

60

49.6m

 

49.6

49.6

 

BELOW SURFACE

80

BELOW SURFACE

m

80

 

SINGLE: Single frequency

DUAL: Dual frequency

f)DISP ORDER sets where to locate the fore and aft displays (right or left side) in the dual frequency display.

g)OUTPUT sets what data to output to external equipment (in IEC/NMEA data format) in case of dual frequencies. Select FORE to output FORE data, or AFT to output AFT data.

h)MEMORIZE sets the source (transducer) for data recording (depth, etc.) in case of dual frequencies. Select DUAL, FORE or AFT as appropriate. DUAL records both FORE and AFT data for 12 hours. FORE or AFT records respective data for 24 hours.

4.Reset the power.

Note: The default settings in the TRANSDUCER SETTING window are N/A. At the first power-up after installation, the window appears to set transducer(s).

23

Page 29
Image 29
Furuno FE-700 installation manual 49.6 m