1.7 Transducer Switch Box EX-8 (option)

If two transducers are installed, the transducers switch box is required. Locate the transducer switch box near the display unit considering length of the interconnection cable. Select the bright place where the panel of equipment can be watched. Use only the screws supplied on the terminal inside to make connections. Use of other screws may cause a short circuit. Compass safe distances are as follows; standard compass: 1.00 m, Steering compass: 0.60 m.

1.8 Gate Valve GV-50B-6B, GV-200B-8B (option)

Assemble the Gate Valve as shown below. Refer to the drawing at the end of this manual.

1.Disassemble the gate valve assembled tentatively: spacer, gasket1, gate valve, gasket 2, O-ring (P170), seachest cap and shaft assembly.

When assembling the gate valve, use original washers, bolts and nuts. Keep the bottom of the seachest cap and the shaft free of dust and be careful not to damage them.

SCALE

GATE VALVE

WASHER

NUT

BOLT

SHAFT

SEACHEST CAP

NUT

1

WASHER O-RING (P135)

O-RING (P170)

GASKET1

GASKET2

SPACER

2.Weld the spacer to the hull bottom.

The hull side of the spacer should be flush with the hull bottom. Be careful not to damage the side fixed to the gate valve.

3.Clean the side of the spacer to be fixed to the gate valve.

9

Page 15
Image 15
Furuno FE-700 installation manual Transducer Switch Box EX-8 option, Gate Valve GV-50B-6B, GV-200B-8B option