Main
SVM125-A
October 1996
Safety Depends on You
CLASSIC II
i i
FOR ENGINE powered equipment.
WARNING
ELECTRIC AND MAGNETIC FIELDS may be dangerous
ii ii
ARC RAYS can burn.
ELECTRIC SHOCK can kill.
FUMES AND GASES can be dangerous.
FOR ELECTRICALLY powered equipment.
CYLINDER may explode if damaged.
iii
WELDING SPARKS can cause fire or explosion.
iv iv
PRCAUTIONS DE SRET
Mar. 93
PRCAUTIONS DE SRET POUR LES MACHINES SOUDER TRANSFORMATEUR ET REDRESSEUR
MASTER TABLE OF CONTENTS FOR ALL SECTIONS
- INSTALLATION SECTION -
TECHNICAL SPECIFICATIONS - CLASSIC II INPUT - DIESEL ENGINE
Manufacturer Description Speed Displacement Ignition Capacities
RATED OUTPUT - WELDER
Duty Cycle Amps Volts at Rated Amperes
OUTPUT - WELDER AND GENERATOR
SAFETY PRECAUTIONS
LOCATION AND VENTILATION
STORING
STACKING
TILTING
PRE-OPERATION ENGINE SERVICE
OIL
FUEL
BATTERYCONNECTIONS
MUFFLER
SPARK ARRESTER
UNDERCARRIAGES
ELECTRICAL OUTPUT CONNECTIONS
WELDING CABLE CONNECTIONS
MACHINE GROUNDING
AUXILIARY POWER RECEPTACLES, PLUGS, AND HAND-HELD EQUIPMENT
CIRCUIT BREAKERS
Page
- OPERATION SECTION -
OPERATING INSTRUCTIONS
SAFETY INSTRUCTIONS
ELECTRIC SHOCK can kill.
FUMES AND GASES can be dan- gerous.
WELDING SPARKS can cause fire or explosion.
RECOMMENDED APPLICATIONS
WELDER
Welding
GENERATOR
OPERATIONAL FEATURES AND CONTROLS
WELDING CAPABILITY
LIMITATIONS
WELDER/GENERATOR CONTROLS
CONTROLS AND SETTINGS
CONTROL OF WELDING CURRENT
FINE CURRENT ADJUSTMENT
CURRENT RANGE SELECTOR
DIESEL ENGINE CONTROLS
ENGINE OPERATION
WARNING WARNING
BEFORE STARTING THE ENGINE
Figure D.1
STARTING THE ENGINE
STOPPING THE ENGINE
COLD WEATHER STARTING
BREAK-IN PERIOD
WELDING OPERATION
GENERAL INFORMATION
Installation
IDLER OPERATION
Technical Specifications
TO USE THE CLASSIC II FOR DC CONSTANT CURRENT STICK OR TIG WELDING:
TO USE THE CLASSIC II FOR DC WIRE FEED WELDING (CONSTANT VOLTAGE) WITH WIRE FEED MODULE:
AUXILIARY POWER
Generator Power Applications,
Accessories
Figure B.1.
Page
- ACCESSORIES -
OPTIONS/ACCESSORIES
TIG WELDING
SEMIAUTOMATIC WELDING
CONNECTION OF THE LN-7 TO THE CLASSIC II USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.1.)
CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS
CONNECTION OF THE LN-7 TO THE CLASSIC II USING K584 INPUT CABLE ASSEMBLY(SEE FIGURE C.2.)
CONNECTION OF THE LN-25 TO THE CLASSIC II USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.3.)
CONNECTION OF THE LN-25 TO THE CLASSIC II ACROSS THE ARC (SEE FIGURE C.4.)
Page
-MAINTENANCE-
SAFETY PRECAUTIONS
Exploded View and Parts List
ROUTINE AND PERIODIC MAINTENANCE
ENGINE MAINTENANCE
WARNING CAUTION
{
Change the Oil
Figure D.1
Page
BATTERYMAINTENANCE
WELDER/GENERATOR MAINTENANCE
IDLER MAINTENANCE
D-8 D-8
FIGURE D.3 - MAJOR COMPONENT LOCATIONS
Section E-1 Section E-1
FIGURE E.1 CLASSIC II BLOCK LOGIC DIAGRAM
ENGINE
-THEORY OF OPERATION SECTION-
NEGATIVE OUTPUT TERMINAL
POSITIVE OUTPUT TERMINAL
115 & 230VAC RECEPTACLES CURRENT TRANSFORMER
FIELD RECTIFIER
GENERAL DESCRIPTION
BATTERY, STARTER, ENGINE, ALTERNATOR, AND PROTECTION CIRCUITS
ENGINE, GENERATOR ARMATURE AND FRAME, ALTERNATOR STATOR AND ROTOR
EXCITATION (FLASHING)
AUXILIARY AND FIELD FEEDBACK COILS
INTERPOLE AND SERIES COILS
ENGINE, GENERATOR ARMATURE AND FRAME, ALTERNATOR STA- TOR AND ROTOR (CONTINUED)
CURRENT RANGE SELECTOR
FINE CURRENT ADJUSTMENT
ENGINE IDLER CIRCUIT
DC GENERATOR MACHINES
Page
TROUBLESHOOTING & REPAIR SECTION
HOW TO USE TROUBLESHOOTING GUIDE
Electrical Diagrams Section Table of Contents
PC BOARD TROUBLESHOOTING PROCEDURES
Flashing the Fields
Alternator Rotor Test.
Shunt Field Winding Test.
Shunt Field Wind- ing Test.
Page
Idler Solenoid Test
Page
Page
ENGINE PROBLEMS
WELDING PROBLEMS
ALTERNATOR ROTOR TEST
Page
Page
Page
SHUNT FIELD WINDING TEST
SHUNT FIELD WINDING TEST (continued)
PLUG P10
Figure F.5.
SHUNT FIELD WINDING TEST (continued)
PIN 3 PIN 5
TAB
IDLER SOLENOID TEST
IDLER SOLENOID TEST (continued)
LEADS #56, #57
ENGINE THROTTLE ADJUSTMENT TEST
STROBE MARK
Strobe Tach Method
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115 VAC SUPPLY) HIGH IDLE - NO LOAD
Figure F.9.
Page
FLASHING THE FIELDS
FLASHING THE FIELDS (continued)
NEGATIVE(-)
Troubleshooting Guide
POSITIVE (+)
12 VOLT BATTERY
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
HIGH IDLE NO LOAD FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM
NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM
HIGH IDLE NO LOAD FINE CURRENT CONTROL RHEOSTAT AND SELECTOR SWITCH AT MAXIMUM
TYPICAL DC WELD OUTPUT VOLTAGE WAVEFORM
MACHINE LOADED SELECTOR SWITCH AT MAXIMUM POSITION
AND REPLACEMENT
REMOVE FASTENERS
BATTERY RETAINER FASTENERS
TERMINAL CABLES
See Figure F.11 for steps 7 - 10.
Page
NEGATIVEOUTPUT TERMINAL (COPPER STRAP ON REAR SIDE)
See Figure F.13 for steps 16 - 17.
Page
Page
Page
ALTERNATOR STATOR REMOVALAND REPLACEMENT
ALTERNATOR STATOR REMOVALAND REPLACEMENT (continued)
COMMUTATOR WRAP-AROUND
F.18.
Figure F.17
ALTERNATOR
Page
GENERNATOR BRUSH HOLDER/COIL CABLES (4)
DRILL SPOT STATOR/ENDBRACKET MOUNTING BOLT
Alternator Rotor Removal and Replacement
GENERATOR FRAME REMOVALAND REPLACEMENT
GENERATOR FRAME REMOVAL
SELECTOR SWITCH CABLES BLUE AND BROWN LEADS
Alternator Stator Removal
GENERATOR FRAME REMOVAL
ENGINE/GENERATOR MOUNTING HOLES
ROPE SLING
See Figure 22 for steps 10 - 13.
Alternator Stator Removal and Replacement Alternator Rotor Removal and Replacement
GENERATOR ARMATURE REMOVALAND REPLACEMENT
GENERATOR ARMATURE REMOVAL
BLOWER PADDLE
Generator Frame Removal
Alternator Stator Removal
BLOWER PADDLE/ARMATURE MOUNTING BOLTS(8)
RETEST AFTER REPAIR
Page
Page
G-2
()
Wiring Diagram (Code 9805 )
*
*
+-
()
Wiring Diagram (Code 10000)
*
+-
L
()
REMOTE CONTROL (OPTIONAL)
*
*
WIRE FEED MODULE (OPTIONAL)
()
REMOTE CONTROL (OPTIONAL)
*
*
WIRE FEED MODULE (OPTIONAL)
*
1-19-96
Wiring Diagram (Code 10219 )
*
*
1-19-96
L9919
CLEVELAND, OHIO U.S.A.
Wiring Diagram (Code 10220)
G-8
Idler PC Board (M13708) Schematic
NONE
R4
ENGINE WELDERS
G-8
G-9
Idler PC Board (M13708) Components
M13708
Q2
C6
G-9
G-10
Idler PC Board (l9902) Schematic
L
IDLER 12 SEC. TIMER
9901
G-10
G-11
Idler PC Board (l9902) Components
L9902
R
IDLER ENGINE SHUTDOWN
G-11