WELDING CAPABILITY

The Classic II is rated 250 amps, 30 volts constant cur- rent DC at 60% duty cycle based on a ten minute time period. Longer duty cycles at lower output currents are possible.

The current is continuously variable from 40 to 325 amps DC.

LIMITATIONS

The Classic II is not recommended for any process- es besides those that are normally performed using DC stick welding (SMAW) and DC TIG welding. Specific limitations on using the Classic II for these processes are described in the Welding Operation section of this manual. Constant voltage welding is available with the optional wire feed module.