| TROUBLESHOOTING & REPAIR | |||
Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |
detailed in the beginning of this manual. |
| |||
|
|
|
| |
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED | |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
The engine will NOT go to high | 1. Check the welding cables and | 1. The Idler PC board may be | ||
speed when either a welding load |
| auxiliary load leads for loose or | faulty. | |
or an auxiliary load is connected to |
| faulty connections. |
| |
the Classic II. | The machine has | 2. | Check for mechanical restric- |
|
normal output | and engine speed |
| ||
| tions or missing parts in the idler |
| ||
when the Idler switch is in the “High |
|
| ||
| and throttle linkage (Springs, |
| ||
position. |
|
|
| |
|
| etc.). |
| |
|
|
|
| |
|
|
|
| |
The engine will not shut down. | 1. | Make sure the ignition switch is | 1. Check the fuel solenoid for | |
|
|
| turned off and operating correct- | proper operation. When 12VDC |
|
|
| ly. | is applied to the solenoid at |
|
| 2. On older machines (below serial | leads #58 (+) to | |
|
| solenoid should be open. When | ||
|
|
| number U1940718502), make | |
|
|
| the 12VDC is removed the sole- | |
|
|
| sure Diode Kit | |
|
|
| noid should close, stopping fuel | |
|
|
| been installed. | |
|
|
| flow to the engine. | |
|
|
|
| |
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call